SSE-14-0022_17
28
7. Maintenance
7.1. Troubleshooting
STATE
CONTENT/PROCEDURE
Cannot turn the power on
Make sure that the power cable has not loosened.
Make sure that the contact of the power cable plug has not stained.
Make sure that the power cable has not damaged.
Make sure that the circuit breaker in the Signal Processing Unit is “ON”.
Thermo electric air conditioner
stopped
Please contact us.
No radar echo indication.
Restart the radar system. (see 6.1)
7.2. Preventative Maintenance
PERIOD
ITEM
CHECK POINT
CONTENT/PROCEDURE
When
needed
Visual check of the
Radar radome
surface.
Sea salt, oil, etc.
adhered to the surface?
Wipe adhering substances with a wet soft
cloth. However, since radome is made with
FRP, don't use gasoline, benzene, and a
solvent like ketone.
After six
months, a
strong wind
or a
thunderbolt
Visual check of the
Radar radome
damage
Any crack?
Please contact to our trouble support after
finished the waterproofing disposal.
After six
months
Fix a protective
tube
Any slack?
Please strengthen fixation of a protective tube.
*Before to start the maintenance, please make sure the power of radar system is off.
Содержание WR-2100