 SAFETY INSTRUCTION

WARNING

WARNING

Do not open the cover of

the equipment.

This equipment uses high
voltage electricity which can
shock or burn.
Only qualified personnel
should work inside the
equipment.

Do not disassemble or modify the
equipment.

Fire, electrical shock or serious injury can
result.

Immediately turn off the power at the
ship's mains switchboard if water or
foreign object falls into the equipment
or the equipment is emitting smoke or
fire.

Continued use of the equipment can cause
fire, electrical shock or serious injury.

Do not operate the unit with wet hands.

Electrical shock can result.

Use the correct fuse.

Use of the wrong fuse can cause fire or
damage the equipment.

WARNING

WARNING

ELECTRICAL SHOCK HAZARD

Only qualified personnel
should work inside the
equipment.

This equipment uses high
voltage electricity which can
shock or burn. 

Turn off the power at the ship's mains
switchboard before beginning the 
installation. Post a warning sign near
the switchboard to ensure that the
power will not be applied while the 
equipment is being installed. 

Serious injury can result if the power is
not turned off, or is applied while the
equipment is being installed.

CAUTION

CAUTION

Observe the following compass safe
distances to prevent interference to a
magnetic compass:

CAUTION

CAUTION

PP-505

1.1 m

0.8 m

standard
compass

steering
compass

Safety Information for Operator

Safety Information for Installer

A warning label is attached 
to the printer. Do not remove 
the label. If the label is missing 
or damaged, contact your dealer 
about replacement.

WARNING

To avoid electrical shock, do not 
remove cover. No user-serviceable 
parts inside.

Name: Warning Label (1)
Type: 86-003-1011
Code No.: 100-236-231

WARNING LABEL

WARNING

Indicates a condition that can cause death or serious 
injury if not avoided.

CAUTION

Indicates a condition that can cause minor or moderate 
injury if not avoided. 

Warning, Caution

Mandatory Action

Prohibitive Action

Read these safety instructions before you operate the equipment. 

Содержание PP-505-FE

Страница 1: ...PRINTER PP 505 FE OPERATOR S MANUAL www furuno com Model For FE 700 FE 800...

Страница 2: ......

Страница 3: ...is product according to local regulations for the disposal of industrial waste For disposal in the USA see the homepage of the Electronics Industries Alliance http www eiae org for the correct method...

Страница 4: ...oard before beginning the installation Post a warning sign near the switchboard to ensure that the power will not be applied while the equipment is being installed Serious injury can result if the pow...

Страница 5: ...erform its intended function unless installed operated and maintained properly Please carefully read and follow the recommended procedures for installation operation and maintenance We would appreciat...

Страница 6: ...RMAL PAPER 3 3 INSTALLATION 4 3 1 Complete Set 4 3 2 General Mounting Considerations 4 3 3 Tabletop Bulkhead Mount 5 3 4 Flush Mount 5 3 5 Wiring 6 4 MAINTENANCE 7 APPENDIX REPLACEMENT OF PRINTER ASSE...

Страница 7: ...0m 35 20 02 N 135 45 15 E 15 1kt 008 0deg M Date Time Depth Draft Latitude Longitude Heading Speed Depth graph Depth data log 2003 12 01 13 05 00 038 6m 01 0m 35 20 02 N 135 45 15 E 15 1kt 008 0deg M...

Страница 8: ...is changed the depth is printed and marked with an asterisk Range 5 m 10 m 20 m 40 m 100 m 200 m 400 m 800 m Note1 Depth range automatically changes depending on the depth range on the navigational ec...

Страница 9: ...in the paper container 6 Press the FEED MARK key to confirm that the paper is properly aligned If the paper comes out with its edges wrin kled continue to press the FEED MARK key Correct alignment wi...

Страница 10: ...to withstand minor shocks and engine vibration but excessive and continued shock can shorten the life of the precision printer mechanism Shock may also degrade the print quality due to uneven contact...

Страница 11: ...kg 107 141 Knob bolt Hanger washer 0 2 Tapping screw Flat washer Hanger 90 60 120 200 480 Bulkhead mount When the unit is installed on the bulkhead fix the hanger as shown below Flush mount panel kit...

Страница 12: ...t 3 Connect the cables at the rear of main unit 4 Fix the main unit to the panel cutout with four tapping screws 5 Fix the flush mount panel to the flush mount angles with the screws and washers suppl...

Страница 13: ...ior The only recommended cleaning material for exterior surfaces is a soft cloth For the interior use a handheld vacuum BE SURE TO TURN OFF THE POWER BEFORE CLEANING THE INSIDE OF THE UNIT Do not use...

Страница 14: ...the main unit assembly by removing the recording paper from the paper container Main Unit Assembly Printer Assembly PANEL CPU Board Do not Disconnect Panel Assembly P4 PH 12P P8 PH 10P P10 PH12P M4 8...

Страница 15: ...ad Head Holder Screwdriver 8 As shown below pass the flexible cable connector side of a new thermal head assembly beneath the guide pins End of Flexible Cable Guide Pin 9 Hold the flexible cable end w...

Страница 16: ...riage with the flexible cable support inserting the projection on the carriage into the hole of the cable Flexible Cable Support Carriage Projection 12 Fold back the end of the cable and insert it int...

Страница 17: ...ad printing system 2 2 Character Alphanumeric 2 3 Dot pitch 0 28 mm dot 2 4 Number of dot in line 300 dots 2 5 Number of characters Max 80 characters line 2 6 Print speed 31 cps 2 7 Roll paper TP 0340...

Страница 18: ...2 0 4 55 2 056 6 10 6 4 5 2 219 4 55 5 5 100 614 2 1 7 06 12 4 614 5 07 1 12 4 614 5 07 1 A 1 1 01 6 2 2 176 0 0 3 6 4 4 5 01 5 4 26 105 056 6 10 6 4 5 22 4170 0 9 4 5 1 01 100 614 2 1 01 100 614 57 5...

Страница 19: ...0 1 5 56 14 0 6 6 19 4 241 7 6 5 22 0 2 1 6 722 4 241 7 6 37 6 5 6 5 A 3 1 01 6 2 52 6 01 0 1 2 46 176 0 9 01 14 2 4 5 6 2 4 8 5 52 4 914 0 37 06 6 4 4 5 1 01 1 01 2 5 2 01 52 4 2 465 56 14 7 5 5 65 2...

Страница 20: ...Dec 08 03 D 1...

Страница 21: ...4 Sep 09 R Esumi D 2...

Страница 22: ...WG No APPROVED CHECKED DRAWN 16 006 3022 0 FM14 2P 2 08S0157 3m PP 505 FE PRINTER 08S0087 2m 1 IV 2sq RED BLK 12 32 VDC T YAMASAKI 2 FITTED AT FACTORY 1 SHIPYARD SUPPLY 6 5 4 EIA232 TD EIA232 RD GND T...

Страница 23: ......

Страница 24: ...is elemental chlorine free FURUNO Authorized Distributor Dealer 9 52 Ashihara cho Nishinomiya 662 8580 JAPAN A JUL 2003 Printed in Japan All rights reserved A4 MAY 26 2014 Pub No OME 23662 A4 TAHA PP...

Отзывы: