FURUNO Warranty for North America 

 

FURUNO U.S.A., Limited Warranty provides a twenty-four (24) months LABOR and twenty-four (24) months PARTS 
warranty on products from the date of installation or purchase by the original owner. Products or components that are 
represented as being waterproof are guaranteed to be waterproof only for, and within the limits, of the warranty 
period stated above. The warranty start date may not exceed eighteen (18) months from the original date of purchase 
by dealer from Furuno USA and applies to new equipment installed and operated in accordance with Furuno USA’s 
published instructions. 
 
Magnetrons and Microwave devices will be warranted for a period of 12 months from date of original equipment 
installation. 
 
Furuno U.S.A., Inc. warrants each new product to be of sound material and workmanship and through its authorized 
dealer will exchange any parts proven to be defective in material or workmanship under normal use at no charge for a 
period of 24 months from the date of installation or purchase. 
 
Furuno U.S.A., Inc., through an authorized Furuno dealer will provide labor at no cost to replace defective parts, 
exclusive of routine maintenance or normal adjustments, for a period of 24 months from installation date provided the 
work is done by Furuno U.S.A., Inc. or an AUTHORIZED Furuno dealer during normal shop hours and within a radius 
of 50 miles of the shop location. 
 
A suitable proof of purchase showing date of purchase, or installation certification must be available to Furuno U.S.A., 
Inc., or its authorized dealer at the time of request for warranty service. 
 
This warranty is valid for installation of products manufactured by Furuno Electric Co. (hereafter FURUNO). Any 
purchases from brick and mortar or web-based resellers that are imported into other countries by anyone other than a 
FURUNO certified dealer, agent or subsidiary may not comply with local standards. FURUNO strongly recommends 
against importing these products from international websites or other resellers, as the imported product may not work 
correctly and may interfere with other electronic devices. The imported product may also be in breach of the local 
laws and mandated technical requirements. Products imported into other countries, as described previously, shall not 
be eligible for local warranty service. 
 
For products purchased outside of your country please contact the national distributor of Furuno products in the 
country where purchased. 

 

WARRANTY REGISTRATION AND INFORMATION 

To register your product for warranty, as well as see the complete warranty guidelines and limitations, please visit 

www.furunousa.com

 and click on “Support”. In order to expedite repairs, warranty service on Furuno equipment is 

provided through its authorized dealer network. If this is not possible or practical, please contact Furuno U.S.A., Inc. 
to arrange warranty service. 

FURUNO U.S.A., INC. 

Attention: Service Coordinator 

4400 N.W. Pacific Rim Boulevard 

Camas, WA 98607-9408 

Telephone: (360) 834-9300 

FAX: (360) 834-9400 

 

 
Furuno U.S.A., Inc. is proud to supply you with the highest quality in Marine Electronics. We know you had several 
choices when making your selection of equipment, and from everyone at Furuno we thank you. Furuno takes great 
pride in customer service.

 

Содержание Network Sounder DFF3

Страница 1: ...NETWORK SOUNDER DFF3 OPERATOR S MANUAL www furuno com MODEL...

Страница 2: ......

Страница 3: ...s product according to local regulations for the disposal of industrial waste For disposal in the USA see the homepage of the Electronics Industries Alliance http www eiae org for the correct method o...

Страница 4: ...RNING Do not open the equipment Only qualified personnel should work inside the equipment Do not disassemble or modify the equipment Fire electrical shock or serious injury can result Turn off the pow...

Страница 5: ...nterference to a magnetic compass WARNING WARNING Do not open the equipment Only qualified personnel should work inside the equipment Turn off the power before beginning the installation Fire or elect...

Страница 6: ...ns 9 1 4 2 Mounting procedure 9 1 5 Optional Temperature Sensors 10 1 5 1 Transom mount temperature sensor T 02MTB 10 1 5 2 Thru hull temperature sensor T 02MSB T 03MSB 11 2 WIRING 12 2 1 Wiring Outli...

Страница 7: ...t NavNet vx2 NavNet 3D and Navnet TZtouch series The DFF3 feeds data about under water conditions via a LAN FURUNO Free Synthesizer FFS transceiver design allows use of user selectable operating frequ...

Страница 8: ...under DFF3 12 24 VDC Low Freq Transducer High Freq Transducer Rectifier PR 62 Speed Temperature Sensor ST 02MSB ST 02PSB Temperature Sensor T 02MTB T 02MSB T 03MSB DFF3 NETWORK SOUNDER ST BY HUB 100 F...

Страница 9: ...t MJ A6SPF0017 050C 001 159 705 10 5 m for NavNet MJ A6SPF0017 100C 001 159 706 10 10 m for NavNet MJ A6SPF0017 200C 001 159 707 11 20 m for NavNet MJ A6SPF0017 300C 001 159 708 11 30 m for NavNet MOD...

Страница 10: ...TWB 6000 2 T 656 FRP 28 88 Steel 28F 8 88B 8 TWB 6000 2 T 657 FRP 50 88 Steel 50B 9B 88B 8 TWB 6000 2 T 658 FRP 50 200 Steel 50 200 1T or TFB 5000 1 T 603 FRP 50 200 1ST T 603F Steel 50 200 12M FRP 1...

Страница 11: ...T 693 F 50 82 Steel 50B 12 82B 35R TFB 7000 2 T 643 FRP TRB 1100 2 T 643 F 50 88 Steel 50B 12 88B 10 TFB 7000 2 T 643 FRP TRB 1100 2 T 643 F 50 200 Steel 50B 12 200B 8 8B TFB 7000 2 T 645 FRP TRB 110...

Страница 12: ...FRP TRB 1100 2 T 649 F 3k 3k 28 38 Steel 28BL 12HR 38BL 15HR TFB 7000 2 T 681 FRP TRB 1100 2 T 681 F Steel 28F 24H 38BL 15HR TFB 7000 2 T 681 FRP TRB 1100 2 T 681 F 28 50 Steel 28BL 12HR 50BL 24HR TFB...

Страница 13: ...00 2 T 681 F Steel 38BL 15HR 50F 24H TFB 7000 2 T 681 FRP TRB 1100 2 T 681 F 38 88 Steel 38BL 15HR 88F 126H TFB 7000 2 T 682 FRP TRB 1100 2 T 682 F 38 150 Steel 38BL 15HR 150B 12H TFB 7000 2 T 683 FRP...

Страница 14: ...0 Steel 88F 126H 200B 12H TFB 7000 2 T 685 FRP TRB 1100 2 T 685 F 1k 28 Steel 28F 8 TFB 5000 1 T 604 FRP TRB 1000 1 T 604 F 50 Steel 50B 6 6B TFB 5000 1 T 605 FRP TRB 1000 1 T 605 F Steel 50B 9B TFB 5...

Страница 15: ...TRB 1000 1 T 702 F Steel 50BL 12HR TFB 5000 1 T 702 FRP TRB 1000 1 T 702 F 82 Steel 82B 35R TFB 5000 1 T 609 FRP TRB 1000 1 T 609 F 88 Steel 88B 10 TFB 5000 1 T 609 FRP TRB 1000 1 T 609 F 200 Steel 2...

Страница 16: ...les for maintenance and servicing ease 3k 28 Steel 28F 24H TFB 4000 1 T 616 FRP TRB 1000 1 T 616 F Steel 28BL 12HR TFB 4000 1 T 616 FRP TRB 1000 1 T 616 F 38 Steel 38BL 15HR TRB 4000 1 T 616 FRP TRB 1...

Страница 17: ...B 1 4 1 Mounting considerations Select a suitable mounting location considering the following points Select a mid boat flat position The sensor does not have to be installed perfectly perpendicular Ho...

Страница 18: ...02MTB Fix the cable at a convenient location with cable clamp When the cable is led in through the transom board make a hole of approx 17 mm in diameter to pass the connector After passing the cable...

Страница 19: ...Guide Sensor Holder T 02MSB T 03MSB Mounting procedure 1 Drill a hole of 21 mm in diameter in the mounting location 2 Pass the sensor cable through the hole 3 Pass gasket washer and locknut onto cable...

Страница 20: ...the hull bottom and connect the ground wire there GROUND MOD Z072 050 5 m option 2 10 m DFF3 Ground wire IV 2 sq BATTERY White Black Shield green 12 24 VDC MJ A3SPF0013 035C 3 5 m High Freq Transduce...

Страница 21: ...vent interference to the sounder This is especially important in the case of power cables from televisions and monitors Cable connection After fabricating the transducer cable connect the transducer c...

Страница 22: ...and slide cable clamp upward 7 Pass the transducer cables through the cable entrance and connect their WAGO connectors to respective terminals inside the equipment 8 Slide the cable clamp downward and...

Страница 23: ...e Airmar make TD ID transducer consult a FURUNO agent or dealer for advice Note 1 For NavNet the tap settings shown on the NETWORK SOUNDER SETUP are different from actual ones Therefore follow the ins...

Страница 24: ...Use this setting for NavNet NavNet vx2 NavNet TZtouch ON Manual IP address assignment Use this setting for NavNet NavNet vx2 NavNet TZtouch and refer to the table on the next page for IP addresses 3...

Страница 25: ...Address OFF OFF OFF OFF SOUNDER 172 031 092 001 ON OFF OFF OFF SOUNDER1 172 031 092 011 OFF ON OFF OFF SOUNDER2 172 031 092 012 ON ON OFF OFF SOUNDER3 172 031 092 013 OFF OFF ON OFF SOUNDER4 172 031...

Страница 26: ...pment state as described in the table below LED state and meaning LED state Meaning Lighting continuously Standby state If for NavNet series no signal is received via LAN for more than 10 minutes the...

Страница 27: ...roblem Once a month Cleaning the network sounder s cabinet Dust or dirt on the cabinet may be removed with a dry cloth Do not use chemical based cleaners to clean the cabinet they can remove markings...

Страница 28: ...an restore all de fault settings or restore those other than transducer and LAN This procedure should only be per formed by a suitably qualified FURUNO technician 1 Disconnect the power and LAN cables...

Страница 29: ...SCREW 5X20 SUS304 000 162 608 10 4 LAN CABLE ASSY MOD Z072 050 000 167 176 10 1 MJ CABLE ASSY MJ A3SPF0013 035C 5A 000 157 939 10 1 DOCUMENT OPERATOR S MANUAL OM 20370 000 168 581 1 1 CODE NUMBER END...

Страница 30: ...X rate 20 2 INTERFACE 2 1 Number of port LAN 1 port Transducer 2 port Temp speed sensor 1 port 2 2 Network Ethernet 10BASE T 100BASE TX 3 POWER SUPPLY 3 1 Network sounder 12 24 VDC 2 8 1 4 A 3 2 Recti...

Страница 31: ...28 Mar 08 R Esumi...

Страница 32: ...NC 1 2 3 4 5 6 7 8 RJ45 1 2 3 4 5 6 E_TD P E_TD N E_RD P E_RD N NC SHIELD MJ A6SPF MJ A6SPF0017 050C 5m 6 MAX 30m HUB 101 ETHERNET HUB 2 2 DISPLAY UNIT NAVNET 1 VX2 NC NC MOD Z072 050 5m 2 10m 2 TRANS...

Страница 33: ...cient Otherwise the invoice with serial number name and stamp of the dealer and date of purchase is shown For the Onboard Warranty your FURUNO certified dealer will take care of all registrations 5 Wa...

Страница 34: ...or its authorized dealer at the time of request for warranty service This warranty is valid for installation of products manufactured by Furuno Electric Co hereafter FURUNO Any purchases from brick a...

Страница 35: ...uses 9 2 9 3 10 3 10 4 10 5 10 8 and 10 9 title and or number and date of issue of the standard s or other normative document s For assessment see EMC Test Report FLI 12 08 007 of 18 February 2008 pre...

Страница 36: ...e free FURUNO Authorized Distributor Dealer 9 52 Ashihara cho Nishinomiya 662 8580 JAPAN A MAR 2008 Printed in Japan All rights reserved C MAR 01 2012 Pub No OME 20370 C 00016858212 00016858212 DAMI D...

Отзывы: