Furuno LH-3000 Скачать руководство пользователя страница 41

FURUNO Warranty for North America 

 

FURUNO U.S.A., Limited Warranty provides a twenty-four (24) months LABOR and twenty-four (24) months PARTS 
warranty on products from the date of installation or purchase by the original owner. Products or components that are 
represented as being waterproof are guaranteed to be waterproof only for, and within the limits, of the warranty 
period stated above. The warranty start date may not exceed eighteen (18) months from the original date of purchase 
by dealer from Furuno USA and applies to new equipment installed and operated in accordance with Furuno USA’s 
published instructions. 
 
Magnetrons and Microwave devices will be warranted for a period of 12 months from date of original equipment 
installation. 
 
Furuno U.S.A., Inc. warrants each new product to be of sound material and workmanship and through its authorized 
dealer will exchange any parts proven to be defective in material or workmanship under normal use at no charge for a 
period of 24 months from the date of installation or purchase. 
 
Furuno U.S.A., Inc., through an authorized Furuno dealer will provide labor at no cost to replace defective parts, 
exclusive of routine maintenance or normal adjustments, for a period of 24 months from installation date provided the 
work is done by Furuno U.S.A., Inc. or an AUTHORIZED Furuno dealer during normal shop hours and within a radius 
of 50 miles of the shop location. 
 
A suitable proof of purchase showing date of purchase, or installation certification must be available to Furuno U.S.A., 
Inc., or its authorized dealer at the time of request for warranty service. 
 
This warranty is valid for installation of products manufactured by Furuno Electric Co. (hereafter FURUNO). Any 
purchases from brick and mortar or web-based resellers that are imported into other countries by anyone other than a 
FURUNO certified dealer, agent or subsidiary may not comply with local standards. FURUNO strongly recommends 
against importing these products from international websites or other resellers, as the imported product may not work 
correctly and may interfere with other electronic devices. The imported product may also be in breach of the local 
laws and mandated technical requirements. Products imported into other countries, as described previously, shall not 
be eligible for local warranty service. 
 
For products purchased outside of your country please contact the national distributor of Furuno products in the 
country where purchased. 

 

WARRANTY REGISTRATION AND INFORMATION 

To register your product for warranty, as well as see the complete warranty guidelines and limitations, please visit 

www.furunousa.com

 and click on “Support”. In order to expedite repairs, warranty service on Furuno equipment is 

provided through its authorized dealer network. If this is not possible or practical, please contact Furuno U.S.A., Inc. 
to arrange warranty service. 

FURUNO U.S.A., INC. 

Attention: Service Coordinator 

4400 N.W. Pacific Rim Boulevard 

Camas, WA 98607-9408 

Telephone: (360) 834-9300 

FAX: (360) 834-9400 

 

 
Furuno U.S.A., Inc. is proud to supply you with the highest quality in Marine Electronics. We know you had several 
choices when making your selection of equipment, and from everyone at Furuno we thank you. Furuno takes great 
pride in customer service.

 

Содержание LH-3000

Страница 1: ...OPERATOR S MANUAL www furuno com LOUD HAILER Model LH 3000 LH 3000CG...

Страница 2: ......

Страница 3: ...ademarks or service marks of their respective holders How to discard this product Discard this product according to local regulations for the disposal of industrial waste For disposal in the USA see t...

Страница 4: ...quipment Fire or electrical shock can result if water leaks in the equipment Keep heater away from equipment A heater can melt the equipment s power cord which can cause fire or electrical shock Use t...

Страница 5: ...Adjusting Listening Volume 11 2 6 Calling All Intercom Stations 11 2 7 Calling a Specific Intercom Station 12 2 8 Receiving a Call from an Intercom Station 12 2 9 Hailing by Voice 13 2 10 Sounding Wa...

Страница 6: ...pecifications are available LH 3000 and LH 3000 CG for U S Coast Guard The two are almost identical the LH 3000 CG is additionally equipped with a Siren Mode Unless otherwise noted LH 3000 refers to b...

Страница 7: ...mote Microphone Auxiliary Audio Source Alarm Sensor 13 6 VDC Standard Supply Optional Supply Local Supply Microphone DIM AFT BOTH FWD ALL AUX FUNC IC 4 IC 3 TOW SAIL HAIL VOL ANCH AGND IC 2 UNWY IC 1...

Страница 8: ...1 set Spare Parts 1 set Template E52 00303 000 149 157 1 See packing list for details Optional supply Name Type Code No Qty Remarks Intercom Speaker LH 3010 000 149 111 1 Max 4 Flush Mount Kit LH 302...

Страница 9: ...the mind the following considerations Locate the unit where the front panel can be easily viewed and operated Leave sufficient space at the sides and rear of your unit for ease of maintenance Locate t...

Страница 10: ...flush mount kit Name Type Code No Qty Flush Mounting Plate TZ7300012A 999 999 025 2 Screw 6X12 SUS304 999 999 026 2 Wing Screw M4X35 SUS304 999 999 027 4 Wing Nut M4 SUS304 999 999 028 4 1 Make a cuto...

Страница 11: ...aker option Four intercom speakers maximum may be connected to get 2 way communications between master station and one or all intercom speakers For mounting dimensions and fixing instructions see the...

Страница 12: ...to the interconnection diagram for detailed information Rear panel layout Ground Terminal External Speaker J2 J3 J1 13 6 VDC Power FWD and AFT terminals SP and CAL intercon station 1 3 terminals MIC...

Страница 13: ...ten screw at top of terminal J2 J3 AFT FWD 13 6V TERMINAL ARRANGEMENT 0V 0V 0V 0V 0V4 CAL4 MIC PTT AUX ALRM SP4 J3 AFT FWD 13 6V J1 0V3 CAL3 SP2 0V1 CAL1 SP3 0V2 CAL2 SP1 J2 4 Set terminal tighten scr...

Страница 14: ...ailer and intercom speaker is greater than 2 m max 20 m use a junction box local supply For the connection to the junction box use cable type CO SPEVV SB C 0 2X2P option and fabricate it as below In t...

Страница 15: ...rminal is either FWD or AFT depending on the location of the speaker Burglar alarm local supply The unit can function as a burglar alarm by connecting an external alarm sensor local supply to the ALRM...

Страница 16: ...e output connectors on the rear panel to the ship s ground 3 SP outputs are floating and must not be connected to either battery or the rear panel Use a normal two conductor insulated speaker wire for...

Страница 17: ...il Select Key Chooses loud hailer speaker to use ALL FWD AFT BOTH 2 Intercom Select Key Chooses which intercom station IC1 IC2 IC3 IC4 to call 3 Upper Signal Select Key Chooses warning signal among YE...

Страница 18: ...C indicators Alarm signal indicators MAN manual STOP ANCH AGND 11 MIC MIC input 12 Speaker 2 2 Turning the Power On Off Turn the LISTEN VOL control clockwise to turn on the Loud Hailer The ALL indicat...

Страница 19: ...t 2 5 Adjusting Listening Volume Turn the LISTEN VOL control to adjust the listening volume from the Loud Hailer s internal speaker and external speaker if connected 2 6 Calling All Intercom Stations...

Страница 20: ...PTT switch on the microphone to answer the call The LH 3000 automatically switches to the calling station and the flashing indicator then lights steadily 2 If necessary adjust listening volume with LI...

Страница 21: ...Hail Select key to return to the standby mode Intercom station operation Press the button on the intercom to call Release the button to listen 2 9 Hailing by Voice 1 Press the Hail Select key until th...

Страница 22: ...he horn speakers sound warning signals and the volume is automatically set to maximum when sounding warning signals Description of warning signals Manual warning signals MAN Signal for passing The len...

Страница 23: ...gnal TOW Warning signal for vessels under tow One 3 second blast followed by one 2 second interval one 1 second blast one 2 second interval one 1 second blast one 2 second interval and one 1 second bl...

Страница 24: ...Signal Select key to select YELP or press the Lower Signal Select key to select MAN The indicator begins flashing for the desired signal 3 Press the FUNC key to activate the warning signal The indica...

Страница 25: ...in to return to automatic warning signals 7 To stop transmitting automatic warning signals press the FUNC key followed by the Hail Select key to return to the standby mode Calling intercom stations wh...

Страница 26: ...RM terminals on the rear panel Both horn speakers are selected automatically when the alarm mode is enabled If the alarm is triggered the volume output is automatically set to maximum Enabling the ala...

Страница 27: ...dicators light YELP indicator goes off After 5 minutes ALL FWD AFT and BOTH indicators go off BOTH indicator lights every four seconds STANDBY STATUS Alarm mode enabled An attempt is made to remove th...

Страница 28: ...he selected intercom station 2 Press the PTT switch on the microphone and speak into it 3 Release the PTT switch to listen for a reply from the selected intercom station If necessary adjust listening...

Страница 29: ...en the equipment Only qualified personnel should work inside the equipment 3 1 Preventive Maintenance General checks Check the following monthly Check all cabling If damaged replace Check connections...

Страница 30: ...roubleshooting Below are simple troubleshooting procedures which the user may follow to try to restore normal operation If normal operation cannot be restored do not attempt to check inside any unit A...

Страница 31: ...0K ohms 3 INPUT SENSITIVITY 3 1 MIC sensitivity 73 3 dB 0 dB 1V Bar 3 2 Aux sensitivity 0 dBm 3 dB at 1 kHz 4 DISTORTION FACTOR 4 1 Hail mode 10 1 kHz 20 W 4 2 Intercom mode 10 1 kHz 4 0 W 5 SIGNAL TO...

Страница 32: ...This page is intentionally left blank...

Страница 33: ...FGMB 6A 125V 000 147 324 00 FGMB 125V 6A PBF 000 157 492 10 INSTALLATION MATERIALS 1 SELF TAPPING SCREW 4 6X20 SUS304 000 162 613 10 1 RUBBER CUSHION 1 TZ7300030A 000 149 771 00 2 RUBBER CUSHION 1 TZ...

Страница 34: ...3 CODE NO FLUSH MOUNTING PLATE TZ7300012A 2 999 999 025 4 CODE NO DIMENSIONS IN DRAWING FOR REFERENCE ONLY DIMENSIONS IN DRAWING FOR REFERENCE ONLY DIMENSIONS IN DRAWING FOR REFERENCE ONLY DIMENSIONS...

Страница 35: ...Y Hatai D 1...

Страница 36: ...Y Hatai D 2...

Страница 37: ...Y Hatai D 3...

Страница 38: ...Y Hatai D 4...

Страница 39: ...AL3 9 8 7 0V ALARM 0V AUX 0V 0V MIC PTT 0V4 SP4 CAL4 J3 IV 1 25 MICROPHONE 1 CO 0 2x2P MAX 5m TTYCS 1 TTYCS 1 1 1 BRN 1 2 LH 3000 CG SIREN MODE SWITCH ALARM SENSOR 1 EXT AUDIO SOURCE 1 J B P P P P RED...

Страница 40: ...cient Otherwise the invoice with serial number name and stamp of the dealer and date of purchase is shown For the Onboard Warranty your FURUNO certified dealer will take care of all registrations 5 Wa...

Страница 41: ...or its authorized dealer at the time of request for warranty service This warranty is valid for installation of products manufactured by Furuno Electric Co hereafter FURUNO Any purchases from brick a...

Страница 42: ...EC 60945 Ed 3 0 1996 clauses 9 2 9 3 10 2 10 3 10 4 10 5 10 8 and 10 9 title and or number and date of issue of the standard s or other normative document s For assessment see EMC Test Report FLI 12 0...

Страница 43: ......

Страница 44: ...l is elemental chlorine free FURUNO Authorized Distributor Dealer 9 52 Ashihara cho Nishinomiya 662 8580 JAPAN A FEB 2004 Printed in Japan All rights reserved E3 APR 26 2017 Pub No OME 56460 E3 ETMI L...

Отзывы: