System Configuration 

AIS Transponder
FA-100

IF-1500AIS

12-24 VDC

NavNet2 Series

Radar, Plotter

Cable 
MJ-A15A3F0013-035

Cable
MJ-A7SPF0003-050 (5 m)

Cable
MJ-A6SPF0012-050 (5 m)*

* 10 m cable optionally

   available

 

 

Mounting 

The unit can be mounted on a desktop or a bulkhead. When choosing a mounting location, 
keep in mind the following points: 

• 

Consider cable lengths. 

• 

Choose a location away from rain and water splash and one which is not in direct 
sunlight. 

• 

Observe the maintenance space noted in the outline drawing to facilitate servicing. 

• 

Observe the compass safe distances noted in the safety instructions at the beginning of 
this manual. 

 
Fix the unit to the mounting location with four self-tapping screws (4x16). Connect cables 
referring to the interconnection diagram. Run a ground wire (local supply) between the 
ground terminal and ship’s superstructure. 
 

Содержание IF-1500

Страница 1: ...AIS INTERFACE IF 1500AIS...

Страница 2: ...uid filled containers on the top of the equipment Fire or electrical shock can result Safety Instructions for the Operator Safety Instructions for the Installer WARNING Turn off the power at the switc...

Страница 3: ...ables connection of the FURUNO AIS Transponder FA 100 to the NavNet2 Series radars to display AIS information on the radar and plotter displays AIS target data input from the transponder are selected...

Страница 4: ...wing points Consider cable lengths Choose a location away from rain and water splash and one which is not in direct sunlight Observe the maintenance space noted in the outline drawing to facilitate se...

Страница 5: ...J1 AIS IN TD A TD B RD H RD C SIG GND SIG GND F G RD H RD C TD A TD B N C N C F G YEL GRN WHT BLK MJ A7SPF0003 050 MJ A7SPF0003 050 AIS External display Aux display Pilot plug AIS External display Au...

Страница 6: ...ies radar or plotter Cleaning Dust may be removed from the cabinet with a soft dry cloth For stubborn dirt water diluted mild detergent may be used Do not use chemical based cleaning agents to clean t...

Страница 7: ...VDO ALR ABK TXT ACA LRI LRF Output data ABM BBM ACK LRI LRF 1 4 DATA OUT port Input data ACK Target quantity Sort condition Output data VDM VDO ALR TXT P sentences 1 5 Digital interface IEC 61162 2 2...

Страница 8: ...AC125V 000 549 063 2 INSTALLATION MATERIALS CP14 06500 MJ POWER CABLE MJ A15A3F0013 035 3A 000 145 880 1 MJ CABLE ASSY MJ A7SPF0003 050 000 136 730 1 MJ SIGNAL CABLE ASSEMBLY MJ A6SPF0012 050 000 134...

Страница 9: ...Y Hatai...

Страница 10: ...2 3 DC IN FUSE 3A DC IN MJ A3SPF 12 24VDC 1 MJ A15A3F0013 035 3A 3 5m 6 PWR 12 24VDC WHT BLK MJ A7SPF003 050 5m 6 WHT BLK YEL GRN RED BLU TD A TD B RD A RD B GND ISO GND ISO TD A TD B NC NC WHT BLK YE...

Страница 11: ......

Страница 12: ...005 4 Printed in Japan 2005 5 23 A2 PUB No OMC 44350 A2 00015285200 00015285200 00015285200 00015285200 DAMI IF 1500AIS 0 0 0 1 5 2 8 5 2 0 0 OMC44350A20 OMC44350A20 OMC44350A20 OMC44350A20 O M C 4 4...

Отзывы: