background image

5

2.2 OID/DID and IMN Settings

OID/DID and IMN are set on the communication unit, usually at the time of installation.
The telephone for HSD calling is alos set by the installing technician. For more informa-
tion, contact a FURUNO dealer or agent.

2.3 Terminal Unit Settings

“9: HSD” is added to the Terminal Setup menu on the terminal unit. Additionally, the HSD
is provided with the lock switch function, which you may set it as shown below.

[Terminal setup]

1: Tel No.1        7: Data
2: Tel No.2        8: Telex
3: Tel No.3        9: HSD
4: Tel No.4
5: Tel No.5
6: Tel No.6
E: Exit
Enter JOB No. 9

[HSD]
Key Lock: Ignore/Valid

Press [9], [2].

Ignore: Lock switch setting ignored;
            receive capability.
Valid:

Lock switch setting followed;

         

cannot transmit when lock

         

switch is in "disable" position.

Press [2], [Enter].

Figure 4 Terminal setup menu

Содержание IB-681

Страница 1: ......

Страница 2: ...Te l e p h o n e 0 7 9 8 6 5 2 1 1 1 Te l e f a x 0 7 9 8 6 5 4 2 0 0 Yo u r L o c a l A g e n t D e a l e r A l l r i g h t s r e s e r v e d P U B N o O M E 5 6 0 9 3 I B 6 8 1 T E N I F I R S T E...

Страница 3: ...quid spills into the equipment Immediately turn off the power at the switchboard if the equipment is emitting smoke or fire Continued use of the equipment can cause fire or electrical shock Contact a...

Страница 4: ...install the equipment where it may get wet from rain or water splash Water in the equipment can result in fire electrical shock or equipment damage Be sure that the power supply is compatible with the...

Страница 5: ...Deleting subscriber number 6 2 4 3 Confirming subscriber number 6 2 4 4 Status display on the terminal unit 6 3 OPERATION 3 1 Calling 7 3 1 1 Automatic HSD call 7 3 1 2 Manual call 8 3 2 Receiving 9...

Страница 6: ...2 2 Modifying the RF CONV board in the communication unit 21 5 2 3 Wiring between HSD modem and communication unit 26 5 2 4 Ground 26 APPENDIX Usage Tips Communication with other makes of Inmarsat B t...

Страница 7: ...d and maintained Please carefully read and follow the recommended procedures for installation operation and maintenance to get maximum performance from this equip ment Features The IB 681 provides glo...

Страница 8: ...4 0 0 3 0 6 1 0 6 1 P C 0 5 9 2 4 4 4 0 0 5 0 6 1 0 6 1 P C Installation Materials CP16 01601 e m a N e p y T o N e d o C y t Q r o t c e n n o C C 8 D 2 0 0 5 2 3 2 E J 7 1 6 4 9 0 2 1 0 0 0 2 r o t...

Страница 9: ...N e p y T o N e d o C y t Q M O R d e m m a r g o r P 1 5 0 1 0 5 6 1 M O R P 0 0 5 1 4 4 4 0 0 1 M O R d e m m a r g o r P 1 6 0 1 0 5 6 1 M O R P 0 1 5 1 4 4 4 0 0 1 Optional Equipment e m a N e p...

Страница 10: ...HSD MODEM IB 681 NETWORK ROUTER COMMUNICATION UNIT IB 281 Coaxial cable ANTENNA UNIT IB 181 Local supply FELCOM 81 Antenna cable Serial cable 9 pin connector Serial straight cable 25 or 37 pin connect...

Страница 11: ...bout 30 sec onds after turning on the IB 681 otherwise the IB 281 may display HSD Fault If the FAIL lamp on the IB 281 goes off then operation is normal DIMMER control Adjusts the illumination of the...

Страница 12: ...nterface connector HSD CTRL Conducts control data communications between communication unit and HSD modem Breaker The red button pops out when overcurrent flows inside the equipment In this case find...

Страница 13: ...connecting with a subscriber 2 1 2 DIP switches Table 1 DIP switch functions o N W S n o i t c n u F F F O N O 1 W S l l a c c i t a m o t u A l l a c t c e r i D l l a c s s e r d d A 2 W S e c a f r...

Страница 14: ...a d l e i F s s e r d d A s s e r d d A d l e i F l o r t n o C l o r t n o C e m a r F S C F e c n e u q e S k c e h C 7 b 1 b 0 b 0 1 1 1 1 1 1 0 1 1 1 1 1 1 1 1 1 0 0 0 1 0 0 1 e r i w l a n g i s...

Страница 15: ...e Terminal Setup menu on the terminal unit Additionally the HSD is provided with the lock switch function which you may set it as shown below Terminal setup 1 Tel No 1 7 Data 2 Tel No 2 8 Telex 3 Tel...

Страница 16: ...Land Earth Station LES Prefix 64k for HSD call 3 Confirm dial tone See table 2 2 4 2 Deleting subscriber number 1 Dial 5 1 2 4 3 Confirming subscriber number HSD communications settings HSD settings...

Страница 17: ...criber number See page 5 Turn off DIP switch SW1 The subscriber is called when the HSD terminal turns on the DTR signal Address call setup See page 13 for sequence Turn on DIP switch SW1 The HSD termi...

Страница 18: ...he HSD port is enabled and data transfer can take place After the number is dialed listen for progress tone to confirm call See the table below When you hear the HSD call successful tone hang up the h...

Страница 19: ...t e m e h t s e v i r r a w o l e b s a s u t a t s R T D n o Address call and DTR ON When a call arrives the HSD modem turns RI ON and then acknowledges reception by sending INC to the HSD terminal...

Страница 20: ...a o s l a s i l a n i m r e t e t o N e z i n o r h c n y s y l l a c i t a m o t u a o t d e r i u q e r s i l a n i m r e t D S H e h T l a n g i s k c o l c d e i r a v o t 3 3 V 25bis Command Ind...

Страница 21: ...e b m u n t s r i f s a r e b m u n e m a S 9 8 7 6 5 4 3 2 1 1 8 0 0 3 0 0 N R C f o d n e w o h s o t d e t r e s n i d n a y t i r a l c r o f d e t r e s n i r e b m u n C I D s l l a c d e v i e...

Страница 22: ...nment req SU NCSI Channal assignment SU NCSA Service addr SU scr vec advise SU HSUB HSUB Scr vec ack SU HSUB Ret carrier ID SU Fill in SU HSUB HSUB CES connect SU HSUB DSR ON CTS DCD ON Call to subscr...

Страница 23: ...hannal assignment SU NCSA Service addr SU scr vec advise SU HSUB HSUB Scr vec ack SU HSUB Ret carrier ID SU Fill in SU HSUB HSUB CES connect SU HSUB CTS OFF CTS DCD ON Call to subscriber Reply from su...

Страница 24: ...nal assignment SU NCSA Service addr SU scr vec advise SU HSUB HSUB Scr vec ack SU HSUB Ret carrier ID SU Fill in SU HSUB HSUB HSUB DSR ON CTS DCD ON Call to subscriber Reply from subscriber Calling op...

Страница 25: ...COM HSUB Ch release SU CESI Ch release SU DTR OFF DCD CTS OFF DSR OFF 10 times Disconnect Figure 8 Automatic call clear sequence 3 4 5 Call clear sequence from land Land clears automatic call then CES...

Страница 26: ...16 3 4 6 Manual call clear sequence CES NCS FELCOM HSUB Ch release SU CESI Ch release SU DTR OFF DCD CTS OFF DSR OFF 10 times Disconnect OFF HOOK Figure 10 Manual call clear sequence...

Страница 27: ...on the rear panel pops out when the voltage input to the equipment exceeds the voltage rating In this case reset the power and press the button to restore normal operation 4 2 Self Test at Terminal Un...

Страница 28: ...t i w e i l y a m m e l b o r p d e t c e n n o c m e l b o r p g n i k c a r t a n n e t n a a n n e t n a t i n u n o i t a c i n u m m o c k c e h c m e d o m D S H n o g n i l b a c D I D D I O t...

Страница 29: ...nt space around the unit for maintenance and checking A magnetic compass will be affected if placed to close to the IB 681 Observe the fol lowing compass safe distances to prevent deviation of a magne...

Страница 30: ...HSD terminal RS 232 interface description Pin male arrangement o N n i P 2 3 2 S R l a n g i S T T I C C t i u c r i C n o i t p i r c s e D l a n g i S E T D E C D 2 D T 3 0 1 a t a D d e t t i m s n...

Страница 31: ...1 3 10 14 16 18 20 21 28 32 37 are not used Figure 15 RS 449 Interface Fabrication of plug case assy Aluminum tape Fold back braided shield onto cable tape shield as shown Cable Cable Clamp Figure 16...

Страница 32: ...p t u p t u o x a m e s i w k c o l c y l l u F 4 Remove the CPU2 Board from the communication unit See Figure 19 for location 5 Replace the ROMs I O CPU and SYS CPU on the CPU2 Board See Figure 17 f...

Страница 33: ...he RF CONV Board INMARSAT B MOBILE EARTH STATION COMPASS BEARING ELEVATION S LEVEL TEL 1 TEL 2 TEL 3 TEL 4 TEL 5 TEL 6 TELEX DATA AOR WEST AOR EAST POR POWER DIMMER LOCK I OR READY TX FAIL FELCOM 81 D...

Страница 34: ...plate Figure 20 Mounting of connector assy 11 For version 2 or higher of the REAR PANEL Board Connect the HSD CTRL connector from the connector assy to J15 on the REAR PANEL Board INMARSAT B MOBILE EA...

Страница 35: ...PANEL Board Detach the REAR PANEL Board Solder the HSD CTRL connector to the following points on the REAR PANEL Board 5 GND 3 TD 2 RD REAR PANEL CONNECTOR ASSY J2 D sub 9 pin 32 2 31 3 39 5 RD TD GND...

Страница 36: ...REF J8 DGPS J11 OUT RF CONV Board J11 Figure 23 Communication unit right side view 14 Attach the cover 15 Plug in all connectors to the rear panel 5 2 3 Wiring between HSD modem and communication unit...

Страница 37: ...ng in the IB 681 Furthermore a propagation delay may occur on the landline between the land terminal and coast earth station depending on the distance between them TCP IP protocol When throughput is s...

Страница 38: ...col ip permit snmp server community public R0 line con 0 exec timeout 0 0 line vty 0 4 password login end cisco1601 This example shows only the minimum necessary settings for confirmation Further deta...

Страница 39: ...receiving end You can connect to an internet service provider with an ordinary modem or termi nal adapter No limitations to software usage Web Browser E mail etc RAMSAT RVH24 ODC Caltronic A S Denmar...

Страница 40: ...E Korea Telecom at Laurentides Korea Telecom 006 BV BF BT BD BHSD AOR E Laurentides Stratos Mobile Networks 013 BV BF BT BD BHSD AOR E Morsviazsputnik at Laurentides Morsviazsputnik 015 BV BF BT BD B...

Страница 41: ...BV BF BT BD BHSD AOR W VSNL at Southbury VSNL 306 BV BF BT BD BHSD IOR Arvi VSNL 306 BV BF BT BD IOR Ausguel France Telecom 011 BV BF BT BD BHSD IOR Beijing Beijing Marine Navigation 868 BV BF BT BD...

Страница 42: ...F BT BD BHSD POR Indot at Perth Indot 007 BV BF BT BD BHSD POR Jabatan Telekom Datastream Technology 888 BV BF BT POR Kumn Korea Telecom 006 BV BF BT BD BHSD POR Malaysia Telecom at Perth Malaysia Tel...

Страница 43: ...el 12 5 dBm 6 Channel Rate 132 Kbps 7 Modulation O QPSK 50 filtered 8 Data Speed 56 64 Kbps synchronous 9 Interface RS 232C Dsub25p RS 449 Dsub37p 2 POWER SOURCE 1 Rated Power 100 220 VAC 10 0 3 0 2 A...

Страница 44: ......

Страница 45: ......

Страница 46: ......

Страница 47: ...mat 4 Command format 4 CRN 10 D Data rate 3 DIC 9 DIMMER control 1 DIP switches 3 Direct call 7 12 DTE 7 DTR 7 9 H HDLC format 4 HSD CTRL 2 HSD DATA 1 2 HSD DATA 2 2 M Manual call 8 14 P POWER switch...

Страница 48: ......

Отзывы: