3. INITIAL SETTINGS
10
3.2
Output Data Sentences
Select output data sentences for external equipment as follows.
1. Press the [MENU] key.
2. Press the CONFIGURATION soft key.
3. Press the SETUP NMEA PORT1 soft key.
4. Press the SELECT SNTNC. soft key to display the SELECT SENTENCE window.
AAM
APB
ON
BOD
BWR*
GGA
GLL
ON
RMA
RMB ON
RMC ON
VTG
ON
WPL
XTE
ZDA
ON
DGPS 3D
SELECT
SNTNC.
ON/OFF
RETURN
SELECT SENTENCE
▲
▲
*: BWR for Rhumb line
BWC for Great circle
Select sentence window
5. Select data sentence you want to output.
6. Press the ON/OFF soft key. To output data, select ON.
7. Repeat to select other sentences.
8. Press the RETURN soft key.
9. Press the [PLOT] key to return the plotter display.