2. WIRING
2-16
2.8
Input Voltage and Fuses
The transceiver unit is shipped from the factory with its input voltage set for 230 VAC
and a 10 A fuse inserted in F601 and F602. For other voltages, change toggle switch
positions and fuses as shown below.
Input voltage and toggle switch
Fuses
Change the fuse in F601 and F602 according to input voltage, referring to the table
below.
Input voltage
S603
S604
S605
Default
setting
100 VAC
L
L
L
-
110 VAC
H
L
L
-
115 VAC
H
H
L
-
220 VAC
H
L
H
-
230 VAC
H
H
H
Default
Input Voltage (TB-B101)
F601
F602
Default
setting
100 VAC
20A
20A
-
110 VAC
-
115 VAC
-
220 VAC
10A
10A
-
230 VAC
Default
WARNING
Use the proper fuse.
Use of a wrong fuse can result in damage to the
equipment or cause fire.
Содержание FSV-85
Страница 28: ...1 HOW TO INSTALL THE SYSTEM 1 20 This page is intentionally left blank ...
Страница 56: ...3 ADJUSTMENTS AND CHECKS 3 10 This page is intentionally left blank ...
Страница 67: ...12 Nov 2010 Y NISHIYAMA D 1 ...
Страница 68: ...4 Feb 2011 Y NISHIYAMA D 2 ...
Страница 69: ...5 Nov 2010 Y NISHIYAMA D 3 ...
Страница 70: ...4 Apr 2014 H MAKI D 4 ...
Страница 71: ...6 Jul 2012 Y NISHIYAMA D 5 ...
Страница 72: ...Nov 22 06 T Matsuguchi D 6 ...
Страница 73: ...22 Apr 2013 Y NISHIYAMA D 7 ...
Страница 74: ...22 Apr 2013 Y NISHIYAMA D 8 ...
Страница 75: ...26 Nov 2010 Y NISHIYAMA D 9 ...
Страница 76: ...27 Dec 2010 Y NISHIYAMA D 10 ...
Страница 77: ...Nov 22 06T Matsuguchi D 11 ...
Страница 78: ...D 12 ...
Страница 79: ...29 Mar 2011 Y NISHIYAMA D 13 ...
Страница 80: ...13 Sep 2011 Y NISHIYAMA D 14 ...
Страница 81: ...13 Sep 2011 Y NISHIYAMA D 15 ...
Страница 82: ...Mar 14 07 R Esumi D 16 ...