3. VERTICAL MODE
3-8
2.
Select [Gain Setting] then push the left-click button.
3.
Press the
H/V/S
key to select the [V] tab.
4.
Select [TVG Distance] then push the left-click button.
5.
Select [Changeable] then push the left-click button.
6.
Select
or
; for [Near], [Med] or [Far] as appropriate then push the left-click
button to change the setting.
Near: Setting range, 50 to 150 m, 10 m increments. Med: Setting range, 300 to
500 m, 20 m increments Far: Setting range, 600 to 1000 m, 40 m increments
7.
Select [Quit] on the setting box then push the left-click button.
Adjust the TVG level for selected TVG distance as below.
8.
Select [TVG-Near], [TVG-Med] or [TVG-Far] as appropriate then push the left-
click button.
9.
Select
or
as appropriate then push the left-click button to change the setting.
The setting range is -5 to 5. The higher the setting, the higher the gain. For strong
echoes such as sea surface reflections or plankton layer lower the setting by 1 or
2.
10. Select [Quit] on the setting box then push the left-click button to close the box.
11. Long-press the
MENU/ESC
key to close all menus.
Current settings
Select item with trackball;
push left-click button to adjust.
Содержание FSV-35
Страница 1: ...COLOR SCANNING SONAR FSV 35 OPERATOR S MANUAL www furuno com Model ...
Страница 12: ...SYSTEM CONFIGURATION x This page is intentionally left blank ...
Страница 88: ...4 NUMERIC GRAPHIC DATA DISPLAY 4 4 This page is intentionally left blank ...
Страница 118: ...7 RECORD RECALL OPERATION 7 8 This page is intentionally left blank ...
Страница 138: ...APPEN I 1 ENU TREE P This page is intentionally left blank ...
Страница 144: ......