1 – 19
6) Press the ENTER/SELECT
key.
7) Press the MENU key.
Trail reference
Echo trails can be displayed relative to own ship
(relative) or with reference to north (true).
1) Press the MENU key.
2) Select the TRAIL menu.
3) Press the ENTER/SELECT
key.
4) Select MODE and press the ENTER/SELECT
key.
5) Select trail reference; true or relative.
6) Press the ENTER/SELECT
key.
7) Press the MENU key.
Trail gradation
Echo trails may be shown in monotone or gradual
shading (multiple). Gradual shading paints the
trails getting thinner with time just like the after-
glow on an analog PPI radar.
Monotone trail
Multitone trail
Figure 1-21 Comparison of
trail gradation types
1) Press the MENU key.
2) Select the TRAIL menu.
3) Press the ENTER/SELECT
key.
4) Select TONE and press the ENTER/SELECT
key.
5) Select SGL or MULT.
6) Press the ENTER/SELECT
key.
7) Press the MENU key.
Trail brilliance
Trail brilliance may be adjusted on the BRILL
menu.
1) Press the MENU key.
2) Select the BRILL menu.
3) Press the ENTER/SELECT
key.
4) Select TRAIL and press the ENTER/SELECT
key.
5) Operate the VRM or EBL control to adjust trail
brilliance.
6) Press the ENTER/SELECT
key.
7) Press the MENU key.
1.26 Electronic Plotting (E-plot)
10 operator-selected targets can be plotted elec-
tronically to assess their motion trends. Five past
positions are marked for each plotted target.
A vector appears as you enter a second plot for a
target and is updated each time a new plot is en-
tered for the target. The vector shows the target
motion trend based on its latest two plots.
Alphanumeric readouts for last-plotted or selected
target appear at the bottom of the display.
It should be noted that the vector and alphanu-
meric target data are not updated in real time, but
only when you enter a new plot.
E-plot requires ship's speed input (automatic or
manual) and a compass signal.
When speed is input by a navigator, own ship
moves in accordance with course; not heading.
Plotting a target
Before plotting a target, select PLOT or ALL on
the MARK & DATA DSP menu.
1) Place the cursor on the target you want to plot,
and press the PLOT SYMBOL key.
2) Watching the E-plot timer on the PLOT mode,
wait at least 30 seconds. Place the cursor on
the plot symbol and press the ENTER/SE-
LECT key. The plot symbol of the target
flashes.
3) While the plot symbol of the target is flash-
ing, place the cursor on the target again and
press the PLOT SYMBOL key. The plot sym-
bol shifts to the new target position and the
previous position is marked by a small dot.