![Furuno FMD-3200 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/furuno/fmd-3200/fmd-3200_installation-manual_2350123022.webp)
2. WIRING
2-2
Notice for the network construction
Pay attention to the following points when installing the network.
• Use HUB-3000 for IEC 61162-450 Ed.2 compliant network. HUB-100 can also be
used to connect IEC 61162-450 Ed.1 compliant network.
• Do not connect the LAN network on board to the above optional HUBs. Also, com-
mercial PCs cannot be connected to the gateway network, other than for mainte-
nance.
• Connect to other ECDIS units and radars (FEA-2xx7, FAR-2xx7 series radars, etc)
using the gateway network.
• When constructing a network with two or more FAR-2xx7 radars, an FMD-3x00 unit
and using a HUB-3000, the HUB-3000 querier must be configured. For how to set
the HUB-3000 querier, see the instruction manual (E42-01204).
• The FMD-3x00 does not support IGMP snooping or CGMP enabled switch.
• The FMD-3x00 does not have a router or repeater hub function.
• The Switching Hub (HUB-100) is optionally available for connection to the FMD-
3x00.
• The Switching Hub (HUB-100) does not support IGMP snooping or CGMP enabled
switch.
• To use IEC 61162-450 compatible sensors, set [Transmission Group] on the [Com-
mon Installation Settings] menu. For how to set [Transmission Group], see the in-
struction manual (E42-01204).
• Modbus is only available for AMS database communication.
• To ensure the security of the FURUNO network, be sure to connect with non-FU-
RUNO networks via the service gateway (tBOX810-83A-FL).
• At least one AMS device must be installed in the navigation system. This ECDIS can
operate as an AMS device as an optional function. When connecting to INS, do not
use this ECDIS as an AMS device.
Notice on wiring
• To use the USB port on the control unit, connect the control unit to the processor
unit, using the USB cable supplied with the control unit or optional USB cable.
• The length of the USB cable should be within 5 m to prevent equipment trouble.
• The length of LAN cables should be within 50 m.
• Use the CAT5E or CAT6 LAN cables for the network if available locally.
• If LAN cables are not available locally, use the optional LAN cables (FR-FTPC-CY
for sensor network, DTI-C5E350 VCV for gateway network).
• If extension or division of the DVI or ERGB cables is necessary, use the dividers
shown below.
• DVI cable divider: DVI-12A (maker: IMAGENICS)
• RGB divider: CIF-12H, DD-106 or WBD-14F (maker: IMAGENICS)
• Make sure that the ground wires are connected between the ground terminals on
each equipment and the ship’s earth.
• If a UPS (user supply) is connected to this equipment, be sure that the grounding
lamp does not light.
Содержание FMD-3200
Страница 20: ...1 MOUNTING 1 10 This page is intentionally left blank...
Страница 70: ...3 ECN 303 304 OPTION 3 8 This page is intentionally left blank...
Страница 72: ...4 SETTING UP THE EQUIPMENT 4 2 This page is intentionally left blank...
Страница 120: ...D 1 29 Nov 2017 H MAKI 29 Nov 2017 H MAKI...
Страница 121: ...D 2 29 Nov 2017 H MAKI 29 Nov 2017 H MAKI...
Страница 122: ......
Страница 123: ......
Страница 124: ...1RY 1 6 0...
Страница 125: ...11 Jan 2018 H MAKI 11 Jan 2018 H MAKI...
Страница 126: ...11 Jan 2018 H MAKI 11 Jan 2018 H MAKI...
Страница 127: ...11 Jan 2018 H MAKI 11 Jan 2018 H MAKI...
Страница 128: ...D 9 14 Jun 2018 H MAKI...
Страница 129: ...D 10 14 Jun 2018 H MAKI...
Страница 130: ...D 11 14 Jun 2018 H MAKI...
Страница 131: ...13 Jan 2012 Y NISHIYAMA DN cn o ou email yoshihiro nishiyama furuno co jp c JP 2012 01 13 14 53 33 09 00...
Страница 132: ...13 Jan 2012 Y NISHIYAMA DN cn o ou email yoshih nishiyama fu o co jp c JP 2012 01 14 54 40 09 0...
Страница 133: ...13 Jan 2012 Y NISHIYAMA...
Страница 134: ...13 Jan 2012 Y NISHIYAMA...
Страница 135: ...D 16 8 Jun 2018 H MAKI...
Страница 136: ...D 17 22 Aug 2019 H MAKI...
Страница 137: ...D 18 6 Apr 2021 H MAKI...
Страница 138: ...D 19 6 Apr 2021 H MAKI...
Страница 139: ...D 20 6 Feb 2020 H MAKI...