1. OPERATION
10
2. If the selected alarm page shows “Off,” press and hold down the
SELECT/CLEAR
key until an alarm setting appears.
3. Press the
APP/TRUE
and
SELECT/CLEAR
keys together to enable
adjustment. The alarm setting starts flashing.
4. Press the
APP/TRUE
key to lower the setting; the
SELECT/CLEAR
key to raise it.
Note:
A low alarm cannot be set higher than its affiliated high (max.)
alarm.
5. Press the
APP/TRUE
and
SELECT/CLEAR
keys together to confirm
setting and restore normal operation.
When an alarm is violated, the buzzer sounds and the alarm icon (
)
flashes. You can silence the buzzer with the
SELECT/CLEAR
key. The
icon continues flashing until the offending alarm is disabled.
While the icon is flashing you can switch between alarm display and cur-
rent display alternately by pressing the
DISP
and
SELECT/CLEAR
keys
together.
Low battery voltage
alarm
battery voltage is lower than
this threshold.
5.0 - 20.0 volts
Alarm description
Alarm
Alarms released when;
Setting range
Содержание FI-507 MULTI XL