24
5 Calibration / Set-up
It is important to carefully calibrate and set-up the instrument. The values are stored in
a non volatile memory.
To access calibration PAGE, press and hold
SET
more than 2 seconds.
To select a calibration code, press
DOWN
,
PLUS
and
MODE
as required.
To return to normal operation mode, press
SET
when the text return [rEt] is displayed.
The calibration routines are divided into four groups:
C10 - C17 = USR, User settings.
C20 - C24 = BSP, Log transducer and temp calibrations.
C30 - C37 = HDC, Compass settings.
C70 - C74 = CON, Configuration of the FI-30 system.
To change a calibration value, press
SET.
To select calibration value, press
DOWN
,
PLUS
and
PAGE
as required.
To lock the selected value, press
SET.
5.1
C10 User settings
To return to normal mode, press
SET
when the text [rET] is
displayed.
5.1.1
C11 Select the dampening
The dampening will effect wind angle, wind speed, boat speed
and VMG. Dampening is between d0 (0s) and d9 (1’20).
To change the dampening, press
SET
and change with
PLUS
or
MINUS
and enter with
SET.
5.1.2
C13 Displaying boat speed, trip log and temperature, option
When set to OFF, the functions will be removed from the
display. The Compass Data instrument may still operate as a
Server in the Nexus Network, transmitting the log and
temperature data to other FI-30 instruments without having the
information displayed on this instrument.
5.1.3
C14 Display NAV functions, option
NAV functions are only useful when the Compass Data is
connected in a Nexus Network with Compass transducer and a
navigator. The selection
NAV On
will add the functions that is
avaliable from the Nexus Network, such as BTW, XTE etc.