background image

0

Содержание FI-304

Страница 1: ...0...

Страница 2: ...1...

Страница 3: ...2...

Страница 4: ...information either you are a cruiser or a racer It is important that you are following this instruction regarding installation and operation If the instrument are to be used in a Nexus Network there...

Страница 5: ...5 3 Advanced use of STR MEM 19 4 5 4 Steer reference AWA option 19 4 5 5 Steer reference BTW option 20 4 5 6 Steer reference CTS option 20 4 5 7 Tactical use of MEM 21 4 5 8 Battery voltage BAT 21 4...

Страница 6: ...5 3 8 C68 Roll adjustment 27 5 3 9 C69 Pitch adjustment 28 5 4 C70 Configure FI 30 29 5 4 1 C71 HDC master 29 5 4 2 C72 Log master 29 5 4 3 C73 Function on terminal In3 29 5 4 4 Connection of trim bu...

Страница 7: ...Instrument FI 30 Compass Data 1 1 Instrument front cover 2 1 Drill template 3 1 Operator s Manual 4 2 Pin bolts for instrument mounting 5 2 Nuts for instrument mounting 5 1 Tube of silicon grease 5 1...

Страница 8: ...7...

Страница 9: ...your boat will allow Plan where to position the transducers Server and instruments Think about leaving space for additional instruments in the future A few do nots you should consider Do not cut the c...

Страница 10: ...he back Note The two nuts must just be tighten by hand Run the Nexus Network cable from the Server to the instrument If you want to cut the Nexus Network cable to length disconnect 4 pole jack plug an...

Страница 11: ...he instrument connection pins at the back of the instrument Press the jack plug onto the instrument pins Press the cable in to the cable leads Mount the connection back cover with the screw Your instr...

Страница 12: ...d instrument 2 1 2 Connections in Nexus Network If you already have a Nexus Network i e a Server it is more practical to connect the transducer to the Server due to the single instrument cable install...

Страница 13: ...trument i e a FI 30 Log you may connect the single log pulse wire from that instrument to the Compass Data instrument terminal 4 If you don t have a log instrument but want to install a log transducer...

Страница 14: ...ts will be addressed by the Remote Control if used The example shows that the instrument version number is 1 00 and the given logical ID number is 16 The ID number will always be 8 if the Compass tran...

Страница 15: ...displayed e g MEM This manual has been written to be Compatible with Compass Tactical Data instrument from software version 1 0 All functions followed by the text option is not valid in a factory set...

Страница 16: ...press 2sec on PAGE will escape from that editing mode 4 2 2 MINUS A press on MINUS moves to the next sub function In edit mode it decreases a digit by one 4 2 3 PLUS A press on PLUS moves to the previ...

Страница 17: ...be set at 4 different levels To access the light control press and hold PAGE for more than 2 seconds The flashing text Lit OFF will be displayed and the display will be lit momentarily To select betw...

Страница 18: ...Compass heading to steer reference The LCD arrow will then point at the text STEER instead of HEADING HDC 360 The text HDC 360 means true or magnetic course for the LCD pointer in a 360 scale STR 60...

Страница 19: ...oat is on course when the LCD pointer is displayed as a vertical line strait up A course deviation is displayed as a filled sector The LCD segments will lit up one by one to form a course deviation se...

Страница 20: ...or wind angle by using the STR function You can not activate or turn the pilot off with STR so use with care 4 5 4 Steer reference AWA option The text OFF or MEM is displayed This function may be used...

Страница 21: ...previous selected function is flashing select BTW and press SET The steer reference BTW is automatically calculated 4 5 6 Steer reference CTS option The text STR OFF or MEM is displayed This steer fun...

Страница 22: ...immed press trim or SET The Compass Data will then store the present course in memory MEM as a reference If you then have a lifter press TRIM again but if you have a header more then 5 10 tack After y...

Страница 23: ...the dead reckoning manually by pressing CLEAR 4 5 13 X track error XTE Option To get this function set NAV On C14 See 5 1 3 The text XTE is displayed shortly when this function is selected then a sym...

Страница 24: ...able is used to connect all instruments You will have NMEA 0183 in out Depth information will if used be repeated at more than one FI 30 instrument Network bonus function When you are using the race t...

Страница 25: ...User settings To return to normal mode press SET when the text rET is displayed 5 1 1 C11 Select the dampening The dampening will effect wind angle wind speed boat speed and VMG Dampening is between...

Страница 26: ...knocked i e sailing 15 lower than the reference set course for more than 5 seconds a timer will pop up telling you the elapsed time spent at knocked angle Also read chapter 4 5 3 Tactical use of MEM 5...

Страница 27: ...utodeviate your Compass Take the boat into a turn in calm sea when steady press SET to start The text DEV starts flashing and a LCD sector will show you the course where to end When you have taken the...

Страница 28: ...riation and alignment error The Compass may be installed reversed 180 but never at perpendicular or 90 relative the centreline Press the SET and adjust ADJ the angle by entering the error If you want...

Страница 29: ...l Adjustment of the pitch offset Mount the pitch transducer according to the instructions Adjust the offset so the pitch is displaying 00 when the boat is horizontal By entering a minus sign in front...

Страница 30: ...still use the water temperature function by connecting the FI 30 log transducer at the Server or at the Wind Data instrument TMP Standard temperature function for the log transducer TRM Use the exter...

Страница 31: ...more than one button in parallel for example one on starboard and one on port side 5 4 5 C74 Demo mode The Compass Data instrument has a built in demonstration mode All values are simulated in this m...

Страница 32: ...neral In most cases the reason for faults in electronic equipment is to be found in poor installations Therefore always first check that installation and connection is made per instructions for instru...

Страница 33: ...Error messages The following messages may appear on the display ERR 2 Nexus Network is missing check colour coded connections ERR 3 No Network data received within a given time ERR 10 Range error caus...

Страница 34: ...lications The most important features are the high update rate fast response times very low data latency 25ms and very high data security even at very long distances Another important feature is that...

Страница 35: ...T 000 041 875 FI 308 SPEED TRIM 000 041 876 FI 309 RUDDER ANGLE 000 041 877 FI 310 ANALOG COMPASS ACCESSORIES PART MODEL 000 041 878 FI 3001 DEPTH DEPTH TRANSDUCER 000 041 879 FI 3002 LOG ST SENSOR 00...

Страница 36: ...KiloMetre KTS KnoTS LCD Liquid Crystal Display LOW LOW MAG MAGnitic MAX MAX MH Miles per Hour MID MID MIX Mixture NAV NAVigation NXT NeXT leg RET RETurn SEA SEA dampening SOG Speed Over Ground STA STA...

Страница 37: ...36...

Страница 38: ...37 22341 1 Edidtion 1...

Отзывы: