background image

0

Содержание FI-302

Страница 1: ...0...

Страница 2: ...1...

Страница 3: ...2...

Страница 4: ...3...

Страница 5: ...5 Clear cancel reset 18 5 2 6 Calibration 18 5 2 7 Lighting 18 6 SPEED functions 19 6 1 SPEED main function 19 6 2 SPEED sub functions 19 6 2 1 TRIP LOG TRP 19 6 2 2 TOTAL LOG LOG 19 6 2 3 MAXIMUM SPE...

Страница 6: ...l template 3 1 Operator s Manual 4 2 Pin bolts for instrument mounting 5 2 Nuts for instrument mounting 5 1 Tube of silicon grease 5 1 Connection cover 5 2 4 pol screw terminal 5 1 Power cable red and...

Страница 7: ...6...

Страница 8: ...Nexus Network is designed with the industry standard RS 485 databus which allows you to connect up to 32 FI 30 instrument units on the single Nexus Network cable thereby allowing you the flexibility t...

Страница 9: ...too short Allow extra cable length at the Server so it can be disconnected for inspection without having to disconnect all attached cables Do not place sealant behind the display The instrument gaske...

Страница 10: ...he 2 holes using a 5 mm 1 4 drill for the two pin bolts Use a 63 mm 2 hole saw to machine the clearance hole for the instrument connection socket Remove the template Screw the two pinbolts to the inst...

Страница 11: ...t 25 cm but not more than 75 cm in front of the keel It should be placed no more than 10 cm off the centreline On sailboats with a pronounced V in the hull such as full keel yachts it might be favoura...

Страница 12: ...perly seated into the fitting 5 With the dummy plug properly installed in the through hull fitting mount the fitting so that the handle is exactly at right angles 90 to the boats centreline For pronou...

Страница 13: ...isolated wires the 4th wire is an earth screen Attach the 4 cable protectors to the wires using a pair of flat pliers Connect the 4 cable protectors to the 4 pole jack plug as shown Apply silicon past...

Страница 14: ...ansducer and the power supply are connected direct to the instrument 1 Disconnect the connector on the transducer cable only used when connecting to Server 2 Connect the transducer to the instrument a...

Страница 15: ...14 3 1 6 Installing transducer to the Server The log transducer are supplied with a connector for quick connection to the server Green Yellow White Screen...

Страница 16: ...order in which you press SET is the same order as the instruments will be given a logical ID number on the Nexus Network The example shows that the instrument version number is 2 0 and the given logi...

Страница 17: ...s refereed to the push button name will appear in bold and CAPITAL letters example PAGE Unless otherwise stated the push button presses are momentary Each time a function is mentioned in the text it w...

Страница 18: ...ss on MINUS moves to the next sub function In edit mode it decreases to the previous digit 5 2 3 PLUS A press on PLUS moves to the previous sub function In edit mode it increases to the next digit 5 2...

Страница 19: ...push buttons The lighting can be set at 4 different levels To quick access the light control press and hold PAGE for more than 2 seconds The flashing text Lit OFF will be displayed and the display wi...

Страница 20: ...ess SET The figure 1 in 10 is flashing If you want to start count down from 10 minutes press SET If you want to start the timer from any other time 59 to 1 minute for example minus 5 minutes 5 STA pre...

Страница 21: ...nly in Nexus Network Depth from the water surface or the keel depending on calibration setting See 7 2 3 C22 Unit available in meters m feet FT or fathoms FA See 7 2 2 C21 The text alternates between...

Страница 22: ...mal mode press SET when the text return RET is displyed To change a calibration value press SET To select calibration value press MINUS PLUS and PAGE as required To lock the selected value press SET I...

Страница 23: ...ce from the sea chart T Log trip counter distance L The current calibration value C New calibration value N If you suspect a current in the water drive the boat in both directions and divide trip coun...

Страница 24: ...minus sign Example 01 2 ADJ The distance from the transducer to the keel is 1 2 m To measure from the water surface use the underlining character _ sign Example _ 00 4 ADJ The distance from the trans...

Страница 25: ...check the following points and make a list of All connected instrument and transducers including their software version numbers Server software version number Nexus Network data bus ID numbers for ea...

Страница 26: ...ations Dimensions Speed log instrument 113 x 113 x23 mm 4 3x4 3 inch Instrument cable 8 m 26 ft Power supply 12V DC 10 16V The instruments are polarity protected Power consumption at 12V Speed log ins...

Страница 27: ...OT 000 041 875 FI 308 SPEED TRIM 000 041 876 FI 309 RUDDER ANGLE 000 041 877 FI 310 ANALOG COMPASS ACCESSORIES PART MODEL 000 041 878 FI 3001 DEPTH DEPTH TRANSDUCER 000 041 879 FI 3002 LOG ST SENSOR 0...

Страница 28: ...27 22338 1 Edidtion 2...

Отзывы: