background image

5. CONFIGURATION FROM PC 

 
 

 

5-9

1

 Double-click the 

MPDS Call Waiting

 icon. 

Exit Menu

2. Call

duration guard

7. Message

indication

4. Set time

zone

3. MPDS Call
   Waiting

 

Click the 

Enab 

or

 Disab

 button. 

Click the 

Save 

button to store the setting. 

 

 

Set time zone 

The UTC time is displayed, getting from the GPS. To display local time, set time 

zone as follows. 

1

 Double-click the 

Set time zone

 icon. 

2

 Press the 

Edit

 button. 

 

3

  Choose the time difference and press the 

selct

 button. 

 

 

Содержание FELCOM 70

Страница 1: ...INMARSAT FLEET F77 SHIP EARTH STATION FELCOM 70...

Страница 2: ...2111 Fax Fax 0798 65 4200 0798 65 4200 FIRST EDITION FIRST EDITION FEB FEB 2004 2004 Printed in Japan Printed in Japan All rights reserved All rights reserved C1 C1 JUL JUL 26 2005 26 2005 Pub No Pub...

Страница 3: ...he human body particularly the eyes ELECTRICAL SHOCK HAZARD Do not open the equipment Only qualified personnel should work inside the equipment Any repair work must be done by a licensed radio technic...

Страница 4: ...old and transfer 2 7 2 11 Internal communication 2 7 2 12 Various call procedures 2 8 2 13 To call FELCOM 70 2 9 2 14 Phone book entry 2 9 2 15 Phone book editing 2 11 2 16 Analogue telephone 2 12 3 H...

Страница 5: ...cess code owner level only 5 14 5 7 4 Restricted SIM usage 5 15 5 8 Software update preparation 5 16 5 9 Configuration menu 5 17 5 9 1 ISDN protocol configuration 5 17 5 9 2 Net service providers owne...

Страница 6: ...to server 6 55 6 3 6 Troubleshooting 6 57 6 3 7 AT commands 6 58 6 3 8 DTE interface 6 68 6 4 Mobile Data Service USB 6 70 6 4 1 PPP modem via USB 6 70 6 4 2 PC setup 6 72 6 4 3 Checking default setti...

Страница 7: ...tenance We would appreciate hearing from you the end user about whether we are achieving our purposes Thank you for considering and purchasing FURUNO equipment Features The FELCOM 70 mainly consists o...

Страница 8: ...or Data MPDS packet data service Distress alert Transmit Frequency 1626 5MHz to 1660 5MHz Receiver Frequency 1525 0MHz to 1559 0MHz Channel Interval 1 25 kHz Min at test mode 5 kHz Voice 40 kHz ISDN...

Страница 9: ...it 25 C to 50 C Communication unit 0 C to 45 C Handset 0 C to 45 C Relative Humidity 95 at 40 C Inmarsat SDM 95 IEC60945 Waterproofing Complies with IEC 60529 Antenna Unit IPX6 Communication Unit IPX0...

Страница 10: ...WALL SOCKET OP16 11 SF 870 G4 FAX SF 370 SF 870 QDGY911912 Analogue to ISDN TA FC755D1 Japanese FAX 8070P 3850 Analogue Telephone 102176 SF 870 ISDN Handset ISDN Handset ISDN Handset Distress Alert Un...

Страница 11: ...t is 100 240 VAC The power requirement is approx 40 W in receive idle mode and approx 150 W in transmit mode The CU supplies 48 VDC power to the ADE through the coaxial cable ISDN Handset The ISDN Han...

Страница 12: ...h 3 1 kHz e g telefax Gr 3 Internal communication Equipment connected to the various interfaces may communicate with each other via an internal MSN Multiple Subscriber Number assigned to each unit Con...

Страница 13: ...ndicator alarm indicator Function keys allows adjusting the earpiece volume during conversation opens closes Phone Book reverts to previous position used to transfer a call selects function menu hands...

Страница 14: ...OM 70 terminal on off the ISDN Handset the Communication Unit CU and the Antenna Unit See figure below for location of the power ON OFF switch and indicator Power ON OFF switch SIM card Cover Power in...

Страница 15: ...he PUK is used the SIM PIN is set to 1 2 3 4 To change or disable the PIN code see 5 3 Access level later in this manual The SIM card can store various information e g PIN code Personal Identification...

Страница 16: ...dicator The alarm indicator flashes when an alarm condition occurs The indicator stops once the alarm has been read in the Display Handset by pressing MENU Information Alarms messages The indicator co...

Страница 17: ...listed by local MSN numbers The data are erased when disconnecting the handset or FELCOM 70 is switched off To redial calls made 1 Press the arrow up key to recall the latest number dialed 2 Use the...

Страница 18: ...FF key or handsfree key With the ISDN Handset in the cradle the loudspeaker and microphone are ON for handsfree operation If lifting the handset the loudspeaker turns off Use the handsfree key to togg...

Страница 19: ...atellite toggles between subscribers R Hang up R MSN Handset ld 2 0 Exception Transfer from analogue to ISDN is not possoble 2 11 Internal communication FELCOM 70 allows calls to be made internally be...

Страница 20: ...Special information services are accessible with 2 digit service address code Note Not all Net service providers offer every service Examples Obtaining assistance from the International Operator 1 1 C...

Страница 21: ...ximum 15 characters and 15 digits Typical 6 character 8 digit entries yield a total of 85 phone numbers The number name list is stored in the Communication Unit Programming 1 Open the phone book menu...

Страница 22: ...an characters change language to Norwegian Names written with none Anglo American characters such as etc can only contain 6 different special characters however 2 equal characters count as 1 Saving 20...

Страница 23: ...ered Use DEL to modify entries Add Entry Edit number Edit name Delete Search book See number Copy Sort by ShrtNo ALPHA Add name Furuno Satcom_ OK Number 004767244700 OK ALPHA Edit name Furuno Satcom O...

Страница 24: ...ve new dial tone and then press the REPETER button Note that this button is for manually dialled numbers only Stored numbers will not be repeated using this method Storing abbreviated numbers Ten subs...

Страница 25: ...all 1 Lift handset and receive dial tone 2 Press MINNE button 3 Press relevant storing address 0 9 The subscriber number is automatically dialled Note If you put the analogue phone facing the key pad...

Страница 26: ...2 OPERATION FROM HANDSET 2 14 This page is intentionally left blank...

Страница 27: ...eady for call Find Any AOR W AOR E POR IOR Region 4 Region 5 Region 6 Region 7 Not in use Active MSN Keyclick Ringer Answer beep Backlight Protocol SW version V1 4 00 290703 Chksum 00F32852 Euro ISDN...

Страница 28: ...HW fwd A98853 010d29m02s E 059d52m11s N Speed 10 5 Course 098 Driver switch Speed Format Flow control System Ctrl SW DSP Monitor KDB RFB ATB Speed Format Flow control RS 232 RS 422 REL 3 0 28 Feb 2005...

Страница 29: ...on POR Indian Ocean Region IOR To select another Ocean Region 1 Open the MENU and press Sat Search Pressing OK opens the list of searching alternatives 2 Select as required When selecting Find Any the...

Страница 30: ...E 80 W 60 W 40 W 100 W 180 W LONGITUDE TEL 870 or 872 Pacific Ocean Region POR TEL 870 or 872 Pacific Ocean Region POR TEL 870 or 874 Atalantic Ocean West Region AOR W TEL 870 or 871 Atlantic Ocean Ea...

Страница 31: ...scroll down to Phone setup and select the Active MSN function 2 Select required identity speech quality Note To change MSN number see 5 13 MSN configuration in this manual Note To close the menu press...

Страница 32: ...outgoing call is answered The signal will also sound when a call is transferred at the remote end The signal is not active during handsfree calls The answer beep can be turned on off as follows 1 Ope...

Страница 33: ...3 3 6 Protocol FELCOM 70 allows selection between the following ISDN protocols Euro ISDN for connection to equipment conforming to the European ISDN standard default NI 1 protocol Not used Note All IS...

Страница 34: ...one of the allowed Net service providers When the Restricted Net function is enabled and with some SIM cards selection of default Net service provider is not possible Changing default Net service pro...

Страница 35: ...ess Test Test Buzzer For Safety Call or Urgency Call specific telephone numbers are prompted for that must be provided by the Net service provider See menu to select function on page 3 2 MAY01 09 15 4...

Страница 36: ...Pressing OK enables the Distress Test function allowing a test alarm transmission If required press ESC to exit Press the DISTRESS BUTTON within 30 secs more than six seconds If you press it after 30...

Страница 37: ...t xon xoff trans can not be used RS 232 B RS 422 driver switch Select data speed format and flow control as described above Switching the driver from RS 232B to RS 422 6 Select Serial Ports and scroll...

Страница 38: ...ormation Diagnostics Forward ld Version Info Network Info Alarms Msgs Position Speed Course Clear Causes Alarm List Info Log On Off HW fwd A98853 IOR Spot 5 Ready for call 010d29m02s E 059d52m11s N Sp...

Страница 39: ...program is available on the enclosed CD and must be installed on the PC hard disk Note To install the vtLite Mobile the user name of the PC should be one byte characters ISDN RS 422 TEL 2 ISDN ISDN I...

Страница 40: ...n displayed c Double click the furuno bat icon 3 Connect the serial cable between the PC serial port and the RS 232 port on the FELCOM 70 Communication Unit See previous page 4 Start the vtLite Mobile...

Страница 41: ...d In global beam GLB is shown If spot selection is not complete SBS is shown as above 2 FELCOM 70 starts searching for last known satellite Ocean Region as default 3 When receiving a satellite signal...

Страница 42: ...ill automatically fine tune to the best signal and accept it Clicking Seek starts the search again If required select a specific satellite by clicking New See also 5 4 Selecting default Net service pr...

Страница 43: ...th 22 digits 19 digits Name length 29 characters 12 characters Entry numbers 0 99 100 and up The SIM card entries and CU entries merge when the card is inserted The list is sorted by name Abbreviated...

Страница 44: ...Edit window 2 on previous page opens the window allowing changes to be made in the Phone book Use Del to modify Remov erases the entry Note The book is also used with the restriction Dial from book on...

Страница 45: ...ce calls Packet switched data calls Mpds including Mobile Packet Data Service calls The FELCOM 70 owner may set the log output mode as follows see 4 5 Traffic log settings paused cleared stops logging...

Страница 46: ...et Data Service calls 6 The call list include data such as Net provider start of the call and duration Scroll to wanted call record and press to display details of the selected call 7 The call details...

Страница 47: ...ed mode and click to select Scroll down to Log incoming calls and click Edit or to enable or disable logging of incoming calls Circuit switched calls 2 Clicking Cct in the Traffic log window 1 shown i...

Страница 48: ...rds 5 Print outputs all unprinted calls tagged with a hash Clicking Tag marks all calls with a hash which adds the records to the printout file Clicking Tag marks the selected call with a hash which a...

Страница 49: ...ted out or saved to disk For default setup see 5 15 Print handling setup Ref no Subscriber number Start date and time Call duration in minutes and seconds Terminal ld Net service provider Click for pr...

Страница 50: ...or default setup see 5 15 Print handling setup Ref no Start date and time Call duration in minutes and seconds Transmitted data Net service provider Click for printout Click to save record file Click...

Страница 51: ...4 EIRP table Exit Menu 2 Call duration guard 7 Message indication 4 Set time zone 4 Alarms and messages 1 Access control 7 Configuration 3 Soft ware update prep Exit Menu 8 Information available 9 Cus...

Страница 52: ...rict SIM usage Software update prep Alarms and messages Configuration menu ISDN configuration Net service providers Set diagnostics USB Spot beam report method Information available Misc versionldinfo...

Страница 53: ...el icon on the Function menu 2 Click Edit to enter modify the PIN code 3 Key in Old PIN code default 1234 New PIN code 4 10 digits possible Retype to confirm Click Ok for each entry and to store new c...

Страница 54: ...touts Modifying password Net Service provider names Restricted dial Restricted SIM usage ISDN configuration except data time element Access code Paid functions Phone name setup Spot beam report method...

Страница 55: ...et access level window again and click Edit to modify the owner password Key in Current password New password 10 12 digits Retype to confirm 4 Click Ok following each entry and store new password To r...

Страница 56: ...double click the Set default Net provider icon to display the current selections SBS COM1 2 Scroll up down to change satellite Edit Ok Selct Position 059d52m12s N 010d29m01s E 511 43C 37C 10 20 UTC 02...

Страница 57: ...ter chosen Net as default Save stores the selected Net provider for this satellite Ocean Region SBS COM1 6 Click Yes sets Net service provider for all satellites Ocean Regions Yes No Position 059d52m1...

Страница 58: ...n 2 Click Edit to set the timer 3 Scroll to select the required limit either Stay connected or in steps between 15 minutes and 12 hours and click Selct to store the setting MPDS call waiting The MPDS...

Страница 59: ...e zone 3 MPDS Call Waiting 2 Click the Enab or Disab button 3 Click the Save button to store the setting Set time zone The UTC time is displayed getting from the GPS To display local time set time zon...

Страница 60: ...ressing ESC or when the Call is finished Data call F2M Fixed to Mobile Fax call When the call is finished the display reverts to idle Setup 1 Double click the Message Indication icon in the Phone setu...

Страница 61: ...include the following menus Access control Restrict dial Access code Restrict SIM usage Software update prep Prepares software update Alarms and messages Indicates alarms and messages See page 7 4 fo...

Страница 62: ...e numbers in FELCOM 70 Phone Book It is still possible to append an entry with number field 0047 means that it is possible to dial all Norwegian numbers When a SIM card is inserted the SIM entries wil...

Страница 63: ...riction mode Scroll up down to select Selct enters the chosen mode 3 Clicking List displays the blocked phone numbers The List key only appears when Current mode is Barred list 4 Clicking Edit allows...

Страница 64: ...r to be dialed e g ISDN Handset 1 2abc 3def 4abc 0 0 8abc 1pqrs 6mno 7pqrs 2abc 4abc 4abc 7pqrs 0 0 A a Analogue telephone 1 2 3 4 0 0 8 1 6 7 2 4 4 7 0 0 Setup 1 Double click the Access code icon in...

Страница 65: ...SIM restrictions owner level only 1 Double click the Restrict SIM usage icon 2 The SIM restrictions window shows an example with the setting Allowed SIM No SIM Click Any default to set FELCOM 70 for...

Страница 66: ...e preparation 1 Open the Function menu and then Advanced function menu 2 Double click the Software update prep icon 3 Press the YES button 4 To view update description press the Descr button 5 Press t...

Страница 67: ...level to choose protocol Protocol Select Euro ISDN for connection of equipment conforming to the European ISDN standard NI 1 can not be used Select same protocol for all ISDN handsets and PC Date time...

Страница 68: ...Clicking Edit opens the window allowing the station code and provider name to be modified Use Del to modify Save stores the changes 4 Clicking New window 2 opens the window allowing station code and p...

Страница 69: ...ced functions 1 Set default Net provider Mail 2 Set access level Exit Menu 4 Set diagnostics 2 Net service providers 7 Spot Beam Report Method Exit Menu 1 ISDN configuration 8 Change tone 9 Spot Beme...

Страница 70: ...lt setting is Single port To set the dual port do as follows 1 Double click the USB icon via the Function menu Advanced functions menu Configuration menu 2 Click the Edit button Three selections are p...

Страница 71: ...Hardware Wizard installs the Nera dual port modem driver required for Dual Port operation Click Next and then Finish to complete the installation 6 The Welcome to the Found New Hardware Wizard now aut...

Страница 72: ...ed for dial ups Nera control Port COM6 9 Open vtLite Mobile and click Port Select the Port COM setting for the new driver i e 6 Click Save Settings 10 Click Mode Terminal MMI to reestablish vtLite Mob...

Страница 73: ...d icon via the Function menu Advanced functions menu Configuration menu 2 Two selections are provided Do not transmit my position May send position default May be changed in owner level only 1 2 4 Set...

Страница 74: ...opens a series of version information windows Network status information owner level only This function displays various network status information 4 Double click the Network status information icon i...

Страница 75: ...setup icon in the Customization menu displays the Phone name i e FURUNO F77 To change key in uppercase lowercase letters as required Use Del to modify Save stores the changes This name appears at som...

Страница 76: ...4 8 kbps speech and 3 1 kHz audio columns of the ISDN PORTS table the Term Id is represented by an X allowing an ISDN Term Id to be used for analogue ports Note A Term Id already entered is not accept...

Страница 77: ...ciple for the other type services It is advisable to note down the selections Provided by ISP Name Service CU ports Term ld IMN 4 8 kbps speech 4 8 kbps speech 64 kbps speech 64 kbps speech 64 kbps da...

Страница 78: ...to enter the owner level password default 1234567890 For security the password should be changed before or after configuration of a device See Changing owner level password on page 5 5 Click to open...

Страница 79: ...N Handset will be the next available MSNs All ISDN Handset are given two MSN numbers one for 4 8K speech and one for 64K speech A ISDN Handset connected to Distress Alert Unit will automatically const...

Страница 80: ...iguration starts the Handset Setup Wizard Enter Name Location of the installed Handset as requipment Require Access Code per call must be unchecked to allow this Handset to be used without entering a...

Страница 81: ...ting an ISDN Handset Unplug the ISDN Handset to be deleted and rightclick the same in the Dedicated Handset list Clicking Test Handset removes its data leaving the Terminal Id and MSN number vacant fo...

Страница 82: ...vice 64 kbps speech service 56 kbps data service V110 64 kbps data service UDI Click to continue Key in MSN number if not using the recommended one Click to enter number Select the required service 3...

Страница 83: ...5 33 5 13 4 RS 232 port Open device manager and click button of the RS232 on the Serial Ports 64K UDI to open Serial Port Setup window Key in MSN number if not using the recommended one Click Proceed...

Страница 84: ...34 5 13 5 USB port Open device manager and click button of the USB on the Serial Ports 64 K UDI USB 53 62 Click to open Serial Port Setup Key in MSN number if no using the recommended one Click Proce...

Страница 85: ...xt to continue Key in MSN number if not using the recommemded one Click OK to enter number The MSNs cab be controlled independently e g if two telephones are given the same MSN they will both respond...

Страница 86: ...installing the software the settings may be transferred back to FELCOM 70 by pressing Load 4 Clicking Restore Factory Defaults loads default FELCOM 70 configurations Printout storing a configuration...

Страница 87: ...37 Configuration printout viewer The list is sorted by Terminal Id Print to local printer Save to disk Terminal ld and MSN number Tyep of service Individual device settings Distress Alarm if attached...

Страница 88: ...t to screen which causes the file to be output via the Printout viewer For an example see 4 6 Traffic Log Printout viewer For direct printout choose Print to default windows printer Print to screen se...

Страница 89: ...te will attempt to communicate using a raw telnet connection to the server address given in the server box It will use the default telnet port 23 If Empty ERB access mode is also ticked then over the...

Страница 90: ...5 CONFIGURATION FROM PC 5 40 This page is intentionally left blank...

Страница 91: ...MPDS can be efficient for applications that involves brief bursts of communication followed by periods of inactivity such as E mail Internet intranet Navigational updates Scada Database queries E com...

Страница 92: ...are Data speed 115200 bps Format 8 data bits no parity 1 stop bit Flow control Hardware RTS CTS Win 2000 XP Std 33 600 bps Modem Drivers 5 4 3 2 1 9 8 7 6 PC serial port RS 232 B ISDN ISDN TEL 3 USB...

Страница 93: ...6 3 6 1 3 MPDS setup Windows XP is used as an example Ensure that vtLite Mobile is closed 1 Open the Control Panel on the PC and double click the Phone and Modem Options icon 2 Click the Modems tab Cl...

Страница 94: ...e Wizard window check Don t detect my modem and click Next Select Standard 33600 bps Modem in the Models field and click Next 4 Select the port to which the Modem driver should be installed Click Next...

Страница 95: ...Select Standard 33600 bps Modem Note The setup for data transfer to the CU is based on the Windows 2000 XP default parameters 8 data bits no parity 1 stop bit flow ctrl Hardware Clicking Properties a...

Страница 96: ...6 DATA COMMUNICATION 6 6 7 Click Create a new connection to open the New Connection Wizard Click Next 8 Check Connect to the Internet Click Next Check Set up my connection manually Click Next...

Страница 97: ...6 DATA COMMUNICATION 6 7 9 Check Connect using a dial up modem Click Next 10 Check Modem Standard 33600 bps Modem Click Next Enter the name for the connection e g MPDS Click Next...

Страница 98: ...ider through your default Net Provider Click Next Check Anyone s use and click Next Note Hash may be omitted on some PCs Windows versions 12 Enter name and password for the connection Uncheck Turn on...

Страница 99: ...6 DATA COMMUNICATION 6 9 6 1 4 Checking default settings 1 Double click Network Connections in the Control Panel 2 Right click the MPDS dial up connection and click Properties...

Страница 100: ...ICATION 6 10 3 Check settings in the MPDS Properties window Modem Standard 33600 bps Modem COM1 Phone number 94 Click Configure 4 In the Modem Configuration window check that the Maximum speed bps is...

Страница 101: ...6 11 5 In the MPDS Properties window click Networking and check that Internet Protocol TCP IP is selected Click Settings 6 In the PPP Settings window Negotiate multi link for single link connections...

Страница 102: ...e Network Connections window i e the preset dial up connection If provided for the specific server connection enter the User name and Password Dialing 94 establishes the MPDS connection via the defaul...

Страница 103: ...Connection in progress Displayed on the PC screen The FELCOM 70 ISDN Handset displays must be in diagnostic mode MPDS TUNED AOR E Spot 6 MPDS Registering AOR E Spot 6 MPDS Registered AOR E Spot 6 MPD...

Страница 104: ...used on the connection http www furuno co jp Connection status Appears when right clicking the MPDS dial up icon or clicking the PC icons in the lower right corner of the screen Note Click Disconnect...

Страница 105: ...elephone number If dialing an international number instead of 94 the terminal switches back to ISDN mode of operation Examples Dialing 94 MPDS via default Net service provider no subscriber number is...

Страница 106: ...isted In the Traffic Log window MPDS note that this information is included for information only and should not be used e g for billing purposes It contains some of the information also indicated in t...

Страница 107: ...inal will not be connected to the Internet In many cases when the MPDS system does not work it is important to verify whether the fault is in the SBS RLES or HLES If this command is performed via e g...

Страница 108: ...y whether or not this has been a SBS or RLES problem Verifying MPDS with AT commands Access to AT commands Instead of using the PC hyperterminal facility access can easily be accomplished using vtLite...

Страница 109: ...not find Dial Up Networking Dial up connection not installed Contact your PC vendor to get the software 3 Connection unsuccessful Wrong connection details Check the phone number user name and password...

Страница 110: ...being used AT WLES The terminal will reply with the LES access code being used If this is not what you expect change the value with AT WLES xxx and save the new value with AT W now check that it is po...

Страница 111: ...ith improving the system please note the contents of these if a problem is encountered C No display Signal Strength Indication For data communication it is of major importance that the mobile has a hi...

Страница 112: ...ed MPDS can be efficient for applications that involves brief bursts of communication followed by periods of inactivity such as E mail Internet intranet Navigational updates Scada Database queries E c...

Страница 113: ...he terminal ON connect the USB cable in both FELCOM 70 and the PC 3 Windows opens the Found New Hardware Wizard See next page ISDN RS 422 TEL 2 ISDN ISDN ISDN ISDN SILENCE SW IND NMEA NMEA TEL 1 TEL 3...

Страница 114: ...losed 1 The Found New Hardware Wizard opens when the USB cable has been connected Check Install from a list or specific location Advanced and click Next 2 Check Don t search I will choose the driver t...

Страница 115: ...dem window click Have disk Windows selects the CD drive and detects the USB driver on the CD automatically Click Ok 4 Select the NERA Generic USB Modem Click Next and then Finish to complete the insta...

Страница 116: ...Nera Generic USB Modem NERA Generic USB Modem Note The setup for data transfer to the FURUNO terminal is based on the Windows 2000 XP default parameters 8 data bits no parity 1 stop bit flow ctrl Hard...

Страница 117: ...6 DATA COMMUNICATION 6 27 3 Click Create a new connection to open the New Connection Wizard Click Next 4 Check Connect to the Internet Click Next Check Set up my connection manually Click Next...

Страница 118: ...A COMMUNICATION 6 28 5 Check Connect using a dial up modem Click Next 6 Check Modem NERA Generic USB Modem Click Next Enter the name for the connection e g MPDS Click Next Modem NERA Generic USB Modem...

Страница 119: ...vider through your default Net Provider Click Next Check Anyone s use and click Next Note Hash may be omitted on some PCs Windows versions 8 Enter name and password for the connection Uncheck Turn on...

Страница 120: ...6 DATA COMMUNICATION 6 30 6 2 5 Checking default settings 1 Double click Network Connections in the Control Panel 2 Right click the MPDS dial up connection and click Properties...

Страница 121: ...Confirm settings in the MPDS Properties window Modem NERA Generic USB Modem Phone number 94 Click Configure Modem NERA Generic USB Modem COM3 4 In the Modem Configuration window check that the Maximum...

Страница 122: ...6 32 5 In the MPDS Properties window click Networking and check that Internet Protocol TCP IP is selected Click Settings 6 In the PPP Settings window Negotiate multi link for single link connections...

Страница 123: ...e Network Connections window i e the preset dial up connection If provided for the specific server connection enter the User name and Password Dialing 94 establishes the MPDS connection via the defaul...

Страница 124: ...Connection in progress Displayed on the PC screen The FELCOM 70 ISDN Handset displays must be in diagnostic mode MPDS TUNED AOR E Spot 6 MPDS Registering AOR E Spot 6 MPDS Registered AOR E Spot 6 MPD...

Страница 125: ...used on the connection http www furuno co jp Connection status Appears when right clicking the MPDS dial up icon or clicking the PC icons in the lower right corner of the screen Note Click Disconnect...

Страница 126: ...elephone number If dialing an international number instead of 94 the terminal switches back to ISDN mode of operation Examples Dialing 94 MPDS via default Net service provider no subscriber number is...

Страница 127: ...ies listed In the Traffic Log window MPDS note that this information is included for information only and should not be used e g for billing purposes It contains some of the information also indicated...

Страница 128: ...DS system does not work it is important to verify whether the fault is in the SBS RLES or HLES If this command is performed via e g Hyperterminal and you get the prompt Registered then the fault is pr...

Страница 129: ...S with AT commands Access to AT commands Instead of using the PC hyperterminal facility access can easily be accomplished using vtLite Mobile or using Hyperterminal Start vtLite again You can now key...

Страница 130: ...Remove previous USB installations via Control Panel System Hardware Device Manager Double click universal serial Bus Controller and uninstall the USB universal Host Controller Warning Remove all USB...

Страница 131: ...lem 1 Reinstall vtLite Mobile 6 Disconnects after some time Wrong setting in dialup Check properties options idle time before hang up 7 All dialups dial in MPDS mode Use AT WS45 1 to set port back to...

Страница 132: ...being used AT WLES The terminal will reply with the LES access code being used If this is not what you expect change the value with AT WLES xxx and save the new value with AT W now check that it is po...

Страница 133: ...ith improving the system please note the contents of these if a problem is encountered C No display Signal Strength Indication For data communication it is of major importance that the mobile has a hi...

Страница 134: ...satellite link is 64 kbps The Mobile Data Service offers 64 kbps connection to the international ISDN PSTN network The service is suitable for applications such as high speed file transfer store and f...

Страница 135: ...are Data speed 115200 bps Format 8 data bits no parity 1 stop bit Flow control Hardware RTS CTS Win 2000 XP Std 33 600 bps Modem Drivers 5 4 3 2 1 9 8 7 6 PC serial port RS 232 B ISDN ISDN TEL 3 USB I...

Страница 136: ...d as an example Ensure that vtLite Mobile is closed 1 Open the Control Panel on the PC and doubleclick the Phone and Modem Options icon 2 Click the Modems tab Click Add see next page Note Setting up i...

Страница 137: ...e Wizard window check Don t detect my modem and click Next Select Standard 33600 bps Modem in the Models field and click Next 4 Select the port to which the Modem driver should be installed Click Next...

Страница 138: ...m Click the Advanced tag and enter command AT WS45 1 Note The setup for data transfer to the Furuno terminal is based on the Windows 2000 XP default parameters 8 data bits no parity 1 stop bit flow ct...

Страница 139: ...6 DATA COMMUNICATION 6 49 7 Click Create a new connection to open the New Connection Wizard Click Next 8 Check Connect to the Internet Click Next Check Set up my connection manually Click Next...

Страница 140: ...Next Check Modem Standard 33600 bps Modem Click Next 10 Enter the name for the connection e g Mobile Data Service via RS 232 Click Next Enter phone number Through some Net Providers dialing 28 automa...

Страница 141: ...Anyone s use and click Next Some Internet Service Providers require user name and password also on number 28 Uncheck Turn on Internet Connection Firewall for this connection Click Next FURUNO 12 Compl...

Страница 142: ...DATA COMMUNICATION 6 52 6 3 4 Checking default settings 1 Double click Network Connections in the Control Panel 2 Right click the Mobile Data Service via RS 232 dial up connection and click Propertie...

Страница 143: ...ck settings in the Mobile Data Service via RS 232 Properties window Modem Standard 33600 bps Modem COM1 Phone number 28 Click Configure 4 In the Modem Configuration window check that the Maximum speed...

Страница 144: ...he Mobile Data Service via RS 232 Properties window click Networking and check that Internet Protocol TCP IP is selected Click Settings 6 In the PPP Settings window Negotiate multilink for single link...

Страница 145: ...ia RS 232 icon in the Network Connections window i e the preset dialup connection Note The vtLite Mobile program must be closed down prior to dialing up the server If provided for the specific server...

Страница 146: ...r program to be used on the connection Connection status Appears when right clicking the Mobile Data Service via RS 232 dial up icon or clicking the PC icons in the lower right corner of the screen No...

Страница 147: ...t the software 3 Connection unsuccessful Other end is not an ISDN connection It is not possible to use the RS 232 port if the modem on the receiver side is not an ISDN modem Wrong connection details C...

Страница 148: ...online to another system the only command it recognises is an escape code that contains three typed pluses which forces the Mobile Data Service back to command mode The following should be done when i...

Страница 149: ...ote AT commands may be entered in either upper or lower case not mixed A T A R instructs the Mobile Data Service to connect the line and start the answer sequence of the incoming call Used when not co...

Страница 150: ...A T Q 1 R the Mobile Data Service does not return responses A T S sets and displays S register values See S Register Commands A T V n R sets the Mobile Data Service response format to words or numbers...

Страница 151: ...ded AT commands A T C n R determines the Data Carrier Detect DCD behaviour A T C 0 R sets DCD always ON A T C 1 R sets DCD only when connected Default A T D n R selects the Data Terminal Ready DTR beh...

Страница 152: ...and W commands The extended AT I AT G and AT W commands are non standard features some of which are de signed specially for the Inmarsat system A T G C A P R displays capabilities supported by FELCOM...

Страница 153: ...e local flow control between the PC and FELCOM 70 A T I C F R displays current settings A T I C F R displays available settings FELCOM 70 to PC reference number n 0 no flow control 1 XON XOFF software...

Страница 154: ...selects Telenor A T W N E R A D T E R allows configuration and monitoring of the FELCOM 70 Ctrl F switches font Ctrl X reverts to AT command mode A T W N E R A M P D S M S N 1 2 3 4 5 6 7 8 9 0 R sets...

Страница 155: ...ating parameters A T S 0 n R specifies automatic answer at the nth ring 0 OFF 1 255 ON A T S 0 n R sets value of register A T S 0 R displays current value of register A T S 0 0 R turns automatic answe...

Страница 156: ...key Default A T S 4 n R stores the ASCII decimal code for the line feed character Authorized codes 0 to 127 A T S 4 n R sets value of register A T S 4 R displays current value of register A T S 4 1 0...

Страница 157: ...e examining DTR 108 2 after dialing and when online with a mobile to net call Range 0 255 hundredths of a second A T S 2 5 n R sets delay value A T S 2 5 R displays current delay value A T S 2 5 5 R s...

Страница 158: ...eceived Data 3 TXD BA D2 103 DCE Transmitted Data 4 DTR 108 DTE Data terminal ready 5 GND 102 Signal ground 6 DSR 107 DCE Data set ready 7 RTS CA S2 105 DTE Request To Send 8 CTS CB M2 106 DCE Clear T...

Страница 159: ...Signal from FELCOM 70 that when ON indicates that a data call setup is in progress 108 Data Terminal Ready Signal from PC This signal is used in the Hotline mode and indicate when going from OFF to O...

Страница 160: ...ellite link is 64 kbps The Mobile Data Service offers 64 kbps connection to the international ISDN PSTN network The service is suitable for applications such as high speed file transfer store and forw...

Страница 161: ...e Found New Hardware Wizard See next page ISDN RS 422 TEL 2 ISDN ISDN ISDN ISDN SILENCE SW IND NMEA NMEA TEL 1 TEL 3 ISDN ISDN TEL 3 USB RS 232 B TEL 4 RS 232 A ISDN TX TX RX RX TEL 4 TX TX RX RX TX T...

Страница 162: ...osed 1 The Found New Hardware Wizard opens when the USB cable has been connected Check Install from a list or specific location Advanced and click Next FELCOM 70 2 Check Don t search I will choose the...

Страница 163: ...dem window click Have disk Windows selects the CD drive and detects the USB driver on the CD automatically Click Ok 4 Select the NERA Generic USB Modem Click Next and then Finish to complete the insta...

Страница 164: ...nter command AT WS45 1 Nera Generic USB Modem Nera Generic USB Modem Properties Note The setup for data transfer to the FURUNO terminal is based on the Windows 2000 XP default parameters 8 data bits n...

Страница 165: ...6 DATA COMMUNICATION 6 75 7 Click Create a new connection to open the New Connection Wizard Click Next 8 Check Connect to the Internet Click Next Check Set up my connection manually Click Next...

Страница 166: ...k Modem NERA F77 USB Modem Click Next Modem NERA F77 USB Modem COM3 10 Enter the name for the connection e g Mobile Data Service via USB Click Next Enter phone number through some Net Providers dialin...

Страница 167: ...TION 6 77 11 Check Anyone s use and click Next 12 Enter name and password for the connection Uncheck Turn on Internet Connection Firewall for this connection Click Next Complete the New Connection cli...

Страница 168: ...Checking default settings 1 Double click Network Connections in the Control Panel 2 Right click the Mobile Data Service via USB dial up connection and click Properties Mobile Data Service via USB Dis...

Страница 169: ...SB Properties window Modem NERA Generic USB Modem Phone number 28 Click Configure Modem NERA Generic USB Modem COM3 28 Mobile Data Service via USB Properties 4 In the Modem Configuration window check...

Страница 170: ...e Mobile Data Service via RS 232 Properties window click Networking and check that Internet Protocol TCP IP is selected Click Settings 6 In the PPP Settings window Negotiate multi link for single link...

Страница 171: ...icon in the Dial Up Networking folder Note The vtLite Mobile program must be closed down prior to dialing up the server Enter the User name and Password provided for the specific server connection Cl...

Страница 172: ...be used on the connection Connection status Appears when right clicking the Mobile Data Service via USB dial up icon or clicking the PC icons in the lower right corner of the screen Note Click Discon...

Страница 173: ...click universal serial Bus Controller and uninstall the USB universal Host Controller Warning Remove all USB drivers 3 Start again from page 6 71 2 Cannot find Network Connection Network connection n...

Страница 174: ...em 1 Reinstall vtLite Mobile 6 Disconnects after some time Wrong setting in dialup Check properties options idle time before hang up 7 All dialups dial in MPDS mode Use AT WS45 1 to set port back to n...

Страница 175: ...to the international ISDN PSTN network The service is suitable for applications such as highspeed file transfer store and forward video e mail and internet PPP Point to Point Protocol Note 128 kbps I...

Страница 176: ...he ISDN port on the communication unit of the FELCOM 70 We recommend Eicon Diva ISDN USB Adapter 3 Turn on the FELCOM 70 and PC Windows opens the Found New Hardware Wizard ISDN ISDN ISDN ISDN ISDN ISD...

Страница 177: ...ng up a connection Windows XP is used as an example Ensure that vtLite Mobile is closed 1 Open the Control Panel on the PC and double click the Network Connections icon 2 Click Create a new connection...

Страница 178: ...DSS1 type switch Click Next Enter MSN 60 for 64 kbps ISDN data service or MSN 65 for 128 kbps shown in example Click Add to enter the MSN and Next to continue 4 Check Connect to the Internet Click Nex...

Страница 179: ...A COMMUNICATION 6 89 5 Check Connect using a dial up modem Click Next Check ISDN channel Eicon DIVA 2 01 S T USB for 64 kbps transmission or All available lines multi linked for 128 kbps example Click...

Страница 180: ...ce via ISDN 128 kbps example Click Next Enter phone number through some Net Providers dialing 90628 automatically connects you to the ISP Internet Service Provider When set up for 64 kbps transmission...

Страница 181: ...Connection Firewall for this connection Click Next Complete the New Connection click Finish FURUNO 9 Click Dial to establish the connection to the server the example applies to 128 kbps transmission...

Страница 182: ...28 kbps Properties window click the Networking tab and check that Internet Protocol TCP IP is selected Click Settings 11 In the PPP Settings window Negotiate multilink for single link connections shou...

Страница 183: ...n status The following status window appears when right clicking the Mobile Data Service via ISDN 128 kbps dial up icon in the Network Connections window or clicking the PC icons in the lower right co...

Страница 184: ...ot an ISDN connection It is not possible to use the RS 232 port if the modem on the receiver side is not an ISDN modem 2 Connection unsuccessful Wrong connection details Check the phone number user na...

Страница 185: ...oblem using vtLite via USB Wrong COM port VtLite only autodetects COM1 COM6 Select appropriate port manually 10 Unable to establish 128 kbps connection Server rejects setup request for the 2nd 64 kbps...

Страница 186: ...6 DATA COMMUNICATION 6 96 This page is intentionally left blank...

Страница 187: ...e cord Power CU off on Disconnect cord from CU and connect it again 3 FELCOM 70 cannot find the satellite No or weak signals Check for correct position of the antenna Check that no obstacles block the...

Страница 188: ...e Net Service Provider or verily that Network status information function displays Region Registration Successful Traffic log is full message appears Connect a PC to FELCOM 70 and read print out the t...

Страница 189: ...t the PC applications vendor for help 9 Routing of calls MSN number not entered properly Make sure that the MSN number entered into FELCOM 70 with the Device Manager is also entered into connected equ...

Страница 190: ...ad in the Display Handset by pressing Information Alarms messages The alarm indicator continues to be displayed if the alarm condition persists IOR KDD Ready for call Service provide Ocean Region Sign...

Страница 191: ...t to On 1 Double click the Advanced functions icon to open the Configuration menu 2 Double click the Configuration Set diagnostics icons Click On Ok to turn on diagnostics 3 Double click the Advanced...

Страница 192: ...ad An alarm will remain active until the problem has been solved Pressing right arrow displays detailed information and moves the alarm to the Information Log 3 The Information log lists previous alar...

Страница 193: ...er Implemented in software REL 2 0 5 Beam selection failed Not ready for call GPS information does not convey the position Wait 15 minutes verify antenna view restart MCU 6 Modem thermometer error No...

Страница 194: ...equest data invalid 11D2 Call failed insufficient digits in service address 11D3 Call failed invalid service address 11D4 Call cleared credit card data information invalid 11D5 Call cleared invalid co...

Страница 195: ...NEL_READY 12B1 11 ipds_too_slow MPDS connection too slow and disconneted by MCU 12B1 12 Control did not grant access to terminal due to conflicting shore call 12B1 13 Control did not grant access to t...

Страница 196: ...ICE_CP or CHNL_ICP no_authorization 12B1 50 CHANNEL_ERROR detected by CHNL_SERVICE_CP or CHNL_ICP burst_not_sent 12B1 51 Precharge terminal has run out of time Must refill before call is possible out_...

Страница 197: ...tor rfb_attenuator_failed 12B1 91 The IPDS MPDS service is not allowed due to local terminal configuration restore to factory defaults 12B1 92 No originator id is defined for IPDS MPDS local configura...

Страница 198: ...ear 1551 Call failed LES congested no channel 1581 Call failed service not provided at this LES 1591 Call failed service temporarily not available at this LES 1592 Call cleared credit card type not su...

Страница 199: ...l pre processing tuning terminal is tuning to the LESP tuned the terminal is tuned to the LESP and awaits a registration possibility registering the terminal has sent one or more registration bursts r...

Страница 200: ...f PDUs received with bad CRCs and the number of PDUs with correct CRCs Take note of this ration when reporting problems related to throughput Connections count The count is an estimate of the number o...

Страница 201: ...n in window 2 displays detailed call data MPDS network used Home LES Tagged for printout NO of 5 and 20ms slots used Forward errors in the MPDS system Forward frames received Tx Rx in Bytes Error in f...

Страница 202: ...following software which changes only the registry concerned with the TCP Example Dr TCP http www dslreports com drtcp Note FURUNO assumes no responsibility or liability for this software Be sure to b...

Страница 203: ...e like Internet e mail and handles MPDS billing system IMN Inmarsat Mobile Number a unique 9 digit number which identifies each device connected to FELCOM 70 Inmarsat International Maritime Satellite...

Страница 204: ...king a SIM card RF Radio Frequency R LES Regional Land Earth Station sets terminal in MPDS list S A operator StandAlone operator who maintains connectivity in the event of Network Coordinating Station...

Страница 205: ...en the land based fixed users and the Mobile Earth Stations MESs Each satellite region is under the control of a Network Coordinating Station NCS which controls and monitors the traffic between the ME...

Страница 206: ...ssible in areas marked with ellipse Transmission frequencies The Inmarsat GAN terminals operate in the following frequency bands MES transmission frequencies 1626 5 MHz 1646 5 MHz MES receiving freque...

Страница 207: ...eports back to the CU for verification of valid NCSC If no valid signal is detected no further automatic action occurs until the CU initiates a new search A search request from the CU may contain chan...

Страница 208: ...nt Internal communication Equipment connected to the various interfaces may communicate with each other via an internal MSN Mobile Subscriber Number assigned to each unit Control interface The RS 232...

Страница 209: ...1 kHz 8 5 Communication path Net service provider The Net service provider issues your user licence and IMN Inmarsat Mobile Number phone numbers It is also responsible for the billing of calls charges...

Страница 210: ...nd transmits its MSN number to the MES The MES routes the MSN to a TermlD LES checks that the RTNID is commissioned before connecting the call to the fixed net PSTN Calls from Mobiles 67244700 LES Tra...

Страница 211: ...ean Region directly 871 AOR E Atlantic Ocean Region East 872 POR Pacific Ocean Region 873 IOR Indian Ocean Region 874 AOR W Atlantic Ocean Region West Call announcement from fixed to mobile The LES us...

Страница 212: ...onfigured to another type than the Terminal Id specifies A telephone Terminal Id can only be routed to a phone type device A telefax Terminal Id can only be routed to a fax device LES Fwd ID Service T...

Страница 213: ...4 8 Mini M 4 8 F 4 8 11 1F Fax B 9 6 M 2 4 Mini M 2 4 21 2F ASD B 9 6 M 2 4 Mini M 2 4 31 3F Telex B 41 4F HSD B 51 5F 64k Data Fleet F77 61 6F 3 1kHz Audio Fleet F77 71 7F 56K Data V 110 Fleet F77 N...

Страница 214: ...pboard maintenance therefore they are not listed in the manual Major modules can be located on the parts location photos on the next several pages Name Code no Remarks DIP LNA PWR 16P0192 TR block HPA...

Страница 215: ...APPENDIX MAINTENANCE PARTS AP 3 HPA block HPA pcb HPA CONT pcb PWR pcb DIP LNA TR block...

Страница 216: ......

Отзывы: