3. SETTINGS AND ADJUSTMENTS
3-2
3.2
Settings from the PC(s)
Enter the following commands in a text file and use TeraTerm to send the file to the
EC-3000.
3.2.1
Antenna height
Antenna height cannot be set from the EC-3000. Set it with a command as follows.
3.2.2
TX channel (TX_CH)
3.3
Settings at Installation of the EC-3000
3.3.1
Initial pulse length settings for each range
Menu operation
:
MENU
[1 ECHO]
[1 CUSTOMIZE ECHO]
[8 PULSE]
Set the pulse length for the ranges shown in the table below.
Menu operation for restoring default pulse lengths
:
MENU
[1 ECHO]
[1 CUS-
TOMIZE ECHO]
[0 DEFAULT]
After restoring the pulse lengths, select [SAVE] to save the settings.
Antenna
height (m)
Command
Antenna
height (m)
Command
5
changeanth 0 0
60
changeanth 0 11
7.5
changeanth 0 1
70
changeanth 0 12
10
changeanth 0 2
80
changeanth 0 13
15
changeanth 0 3
90
changeanth 0 14
20
changeanth 0 4
100
changeanth 0 15
25
changeanth 0 5
110
changeanth 0 16
30
changeanth 0 6
120
changeanth 0 17
35
changeanth 0 7
130
changeanth 0 18
40
changeanth 0 8
140
changeanth 0 19
45
changeanth 0 9
150
changeanth 0 20
50
changeanth 0 10
TX CH
Command
CH1
txchset 1
CH2
txchset 2
CH3
txchset 3
Range (nm)
Pulse length setting
0.5 S1
0.75
S1
1.5
S1
3
S2
6
M1
12
M1
24
M2
Содержание FAR-3220Z