1. INSTALLATION AND WIRING
12
5. Apply adhesive to the ground terminal after fastening the terminal screw.
6. Secure the ground wire to the ship’s ground.
The figures shown below are examples for grounding.
7. Secure the cable assembly to the cable cover with the cable ties (local supply) as
shown in the figure below.
8. Reattach the cable cover.
9. Connect the LAN connector of the cable assembly to a LAN port on the FURUNO
Multi Function Display or Ethernet HUB.
Note 1:
Do not connect the LAN connector to on-board LAN.
Adhesive
Ex.1
Ex.2
Adhesive
Adhesive
Hex. bolt
Flat washer
Flat washer
Spring washer
Hex. nut
Ground wire
Ground wire
Hex. nut
Spring washer
Flat washer
Hex. nut
Weld here.
Fix the cable to this cable
clamp, using a cable tie.
Fix the cable to this cable
clamp, using a cable tie.
Ground wire from
the ship's ground
Ground wire from
the ship's ground
Cable assembly
Cable assembly
Power/LAN cable
Power/LAN cable
Ground wire from
the antenna unit
Ground wire from
the antenna unit
If the cable is run through a
radar mast and the bottom of the
unit, fix the cable to this cable
clamp.
If the cable is run through a
radar mast and the bottom of the
unit, fix the cable to this cable
clamp.
Cable cover - bottom view
Содержание DRS12A X-Class
Страница 2: ......
Страница 20: ...1 INSTALLATION AND WIRING 14 ...
Страница 28: ...2 INITIAL SETUP 22 This page is intentionally left blank ...
Страница 41: ...3 Aug 2020 H MAKI D 1 ...
Страница 42: ...D 2 4 Feb 2021 H MAKI ...