23
Registering Procedure
1. Press the
MENU
key.
2. Rotate the
RANGE
control to select FUNC KEY PROG.
3. Rotate the
GAIN
control to select FUNC1 or FUNC2.
4. Press the
TX
key. Each time the TX key is pressed, the current
settings in the scan menu and E/S menu are recorded.
When FACTORY is selected, the default value is displayed.
Recalling Procedure
1. Press
F1
or
F2
. Presetting function is recalled and function indi-
cation (LED lamp) lights.
Canceling the recalling
1. Press
F1
or
F2
again. The LED lamp goes off.
Recommended Settings
We recommend the function key be set as follows,
TX OUTPUT
PULSELENGTH
TX CYCLE
TVG NEAR
TVG FAR
HOR BEAM ANGLE
VER BEAM ANGLE
RES COL CURVE
COL EMPHASIS
8
7
10
5
5
NARROW
NARROW
LINEAR
3
For detection of surface fish school
TX OUTPUT
PULSELENGTH
TX CYCLE
TVG NEAR
TVG FAR
HOR BEAM ANGLE
VER BEAM ANGLE
RES COL CURVE
COL EMPHASIS
8
8
10
6
7
NARROW
WIDE
2
3
For detection of midwater fish
TX OUTPUT
PULSELENGTH
TX CYCLE
TVG NEAR
TVG FAR
HOR BEAM ANGLE
VER BEAM ANGLE
RES COL CURVE
COL EMPHASIS
7
5
10
5
6
NARROW
WIDE
3
1
For detection of bottom fish
Содержание CSH-5 MARK-2
Страница 1: ...COLOR SCANNING SONAR CSH 5 MARK 2 ...
Страница 8: ...2 2 SYSTEM CONFIGURATION System Configuration ...
Страница 55: ...49 3 Echo Sounder Combination Mode COMBI 1 Normal Echo Sounder 16 Color Bar Sonar Picture Echo Sounder Picture ...
Страница 56: ...50 4 Sonar Combination COMBI 2 Normal Signal on R B Mark 16 Color Bar Sonar Picture Signal on R B Mark ...