background image

HOW TO SELECT BACK-UP NAVIGATOR 

 
 
1)  Press the FUNC SET key.    A menu window will appear on the screen. The menu contains a cursor 

(blue triangle) and three items.    See Fig. a). 
 
 

2)  Press the keys in the following manner. (Password entry): See Fig. b). 

 

 

EXTERNAL 

ALARM 

 

LOCAL 

ALARM 

 

 

 

HARBOUR 

CONNING 

 

   
3)  Move the cursor to the “Backup Officer” position with the MOVE UP and MOVE DOWN keys, and 

press the ENTER–key. A list of back-up officers appears on the menu window as Fig. c). 
 
 
 
 
 
 
 
 
 
 
 
 
 
   a) Menu window 

 

       b) Menu Window   

 c) Backup Officer 

        (normal) 

 

 

          (password entered) 

 

     

selecting menu 
 
 

4)  Pull down the cursor to the wanted back-up   

officer position, and press the ENTER key. 
Backup officer indication on the Conning   
page changes to the selected back-up officer. 
 
 

5)  Press the FUNC SET button again. The menu window is closed. 
 

 

The selection of back-up navigator should be managed by the captain or 
other authorized person.    Keep this page under the control of them.

 

 

 

Содержание BR-2000

Страница 1: ...BRIDGE ALARM MONITORING WATCH SAFETY SYSTEM BR 2000...

Страница 2: ...Alarm categories 10 2 2 2 1 Group alarms 10 2 2 2 2 Detailed alarms 10 2 2 3 Alarm types 10 2 2 3 1 Event alarm 10 2 2 3 2 State alarm 10 2 3 Alarm Conning control panel 11 3 WATCH SAFETY SYSTEM WSS 1...

Страница 3: ...ure his well being The system operation is divided in two independent Programmable Logic Computer PLC systems one taking care of Alarm Monitoring and the second one to take care of Watch Safety System...

Страница 4: ...formation is mainly received from following external systems ECDIS processor waypoint information Track pilot heading order steering mode and Off Track information Autopilot heading order and steering...

Страница 5: ...Fig 2 Main Conning Page Fig 3 Harbour Conning Page...

Страница 6: ...ies are as followings Emergency alarms alarms which indicate that immediate danger to human life or to the ship and its machinery exists and that immediate action must be taken Distress urgency and sa...

Страница 7: ...Fig 4 Navigation Alarm Fig 5 External Alarm Fig 6 Local Alarm...

Страница 8: ...ECT BACK UP NAVIGATOR not accessible to other persons than service engineers See the leaflet INSTALLATION PARAMETER SETTING How to print out the History Alarm 1 Press the FUNC SET key A menu window wi...

Страница 9: ...t controls Bridge power supply and distribution box Watch safety system Other bridge equipment or systems which can be included in the AMS Propulsion system Engine automation GMDSS and Navtex Fire det...

Страница 10: ...m Event alarm is an alarm which is normally used only to alert operator but does not require any alarm acknowledgement This type of alarm may activate sound alarm in the external system or may be only...

Страница 11: ...e display Move Down will move the cursor to next row down on the display Alarm Acknowledge push button will acknowledge bridge alarm Alarm Pages will select the Navigation External and Local alarm pag...

Страница 12: ...alarm resets automatically the time interval between warnings Manual adjustment of main navigation equipment controls is also used for this purpose In the event that the watchkeeper fails to respond a...

Страница 13: ...has failed to acknowledge the watch period warning in 30 seconds or if any alarm has not been acknowledged on the bridge within 60 seconds Buzzer will sound in case the watchkeeper has failed to ackn...

Страница 14: ...in In case the operator fails to respond to any bridge alarm within 60 seconds alarm is transferred to captain s cabin public areas and back up navigator s cabin Dimmer potentiometer will adjust the b...

Страница 15: ...ase the watchkeeper has failed to acknowledge the watch period warning in 30 seconds or if any alarm has not been acknowledged on the bridge within 60 seconds In case the bridge officer is pressing Ca...

Страница 16: ...4 FLOW CHART OF AMWSS Following flow chart illustrates the principal functions of Alarm Monitoring and Watch Safety System...

Страница 17: ...DOWN keys and press the ENTER key A list of back up officers appears on the menu window as Fig c a Menu window b Menu Window c Backup Officer normal password entered selecting menu 4 Pull down the cur...

Отзывы: