SYSTEM CONFIGURATION

vi

X-band (TR-DOWN)

Gyrocompass*

1

 (AD-10 format)

Gyrocompass*

1

 (IEC61162 format)

AIS Transponder

EPFS*

2

 (GPS)

SDME (Speed log)

AMS (IEC61162 format)

ECDIS

AMS (Contact)*

4

Sub monitor

Antenna Cable

100-115/220-230 VAC 

1ø, 50-60 Hz

(for de-icer)

Processor 

Unit

RPU-025

Transceiver Unit

RTR-108

Antenna Unit
for FAR-2328W, 25 kW

(

w/ Performance Monitor PM-32A)

XN20CF-RSB130
XN24CF-RSB130

Wave guide

Signal cable

Sub monitor 1 of ECDIS*

8

Sub monitor 2 of ECDIS*

8

Control Unit

RCU-014 or RCU-015

Control Unit RCU-016

: Standard supply
: Optional or local supply

USB Device*

9

USB Mouse

100-230 VAC 

1ø, 50-60 Hz

Transformer

440 VAC 

1ø, 50-60 Hz

Switching Hub

HUB-100

Monitor Unit*

3

 

MU-190 or 
MU-231 or 

MU-270W

Intelligent Hub 

HUB-3000*

5

100-230 VAC

100-230 VAC

Intelligent Hub 

HUB-3000*

6

100-230 VAC

OR

100-230 VAC

VDR

(IEC61162-450 format)

Sensors

(IEC61162-450 format)

VDR

(Analog RGB)

Содержание 9ZWRTR122

Страница 1: ...2 1 Overview 2 1 2 2 Antenna Unit for X band TR UP Radar 2 5 2 3 Antenna Unit for X band TR DOWN Radar 2 19 2 4 Antenna Unit for S band TR UP Radar 2 26 2 5 Antenna Unit for S band TR DOWN Radar 2 40 2 6 Power Supply Unit 2 46 2 7 Transceiver Unit 2 53 2 8 Processor Unit 2 59 2 9 Monitor Unit 2 66 2 10 LAN Signal Converter 2 68 2 11 Junction Box option 2 71 2 12 Intelligent HUB option 2 72 2 13 VD...

Страница 2: ...KLV PDQXDO LV HOHPHQWDO FKORULQH IUHH 85812 XWKRUL HG LVWULEXWRU HDOHU VKLKDUD FKR 1LVKLQRPL D 3 1 129 3ULQWHG LQ DSDQ OO ULJKWV UHVHUYHG 3XE 1R 20 5 5 Pub No IME 36520 E11 A NOV 2017 E11 FEB 28 2019 AKMU FAR 2xx8 series ...

Страница 3: ... not open the equipment This equipment uses high voltage electricity which can shock burn or cause serious injury Only qualified personnel can work inside the equipment WARNING Turn off the power at the mains switchboard before beginning the installation Fire electrical shock or serious injury can result if the power is left on or is applied while the equipment is being installed Be sure that the ...

Страница 4: ...7 m 1 4 m 0 9 m 0 6 m 2 7 m 1 7 m 1 3 m 4 4 m 3 0 m 2 5 m 9 5 m 6 8 m 5 5 m FAR 2328W FAR 2238S BB FAR 2338S NXT FAR 2238S NXT BB FAR 2338SW XN20CF XN24CF SN24CF SN30CF SN36CF SN24CF SN30CF SN36CF SN36CF 0 5 m 0 3 m N A 0 26 m 2 3 m 1 2 m 0 9 m 5 5 m 4 0 m WARNING Model Transceiver Magnetron FNE1201 MG5436 MG5223F Antenna 100 W m2 50 W m2 10 W m2 Magnetron radar Solid state radar 1 7 m 1 4 m N A N...

Страница 5: ...0 VAC 1ø 50 60 Hz USB Mouse Switching Hub HUB 100 Control Unit RCU 014 or RCU 015 Control Unit RCU 016 Monitor Unit 3 MU 190 or MU 231 or MU 270W Intelligent Hub HUB 3000 5 Gyrocompass 1 AD 10 format Gyrocompass 1 IEC61162 format AIS Transponder EPFS 2 GPS SDME Speed log AMS IEC61162 format Sub monitor 1 of ECDIS 8 Sub monitor 2 of ECDIS 8 AMS Contact 4 Sub monitor Antenna Cable 10 100 115 220 230...

Страница 6: ...0 60 Hz External radar Sub monitor 2 Power Supply Unit PSU 019 Sensors IEC61162 450 format Antenna Cable LAN serial Sub monitor 3 Sub monitor 1 100 230 VAC 1ø 50 60 Hz VDR IEC61162 450 format Monitor Unit 3 MU 190 MU 231 MU 270W Control Unit RCU 014 RCU 015 RCU 031 Intelligent Hub HUB 3000 5 Switching Hub HUB 100 6 Control Unit RCU 014 RCU 015 RCU 031 Control Unit RCU 016 Processor Unit RPU 025 In...

Страница 7: ... Antenna Unit for FAR 2238S NXT BB 2338S NXT 250 W w Performance Monitor PM 52B 7 SN24CF RSB133 111 11 SN30CF RSB133 111 11 SN36CF RSB133 111 Sub monitor 1 of ECDIS 8 Sub monitor 2 of ECDIS 8 Control Unit RCU 014 or RCU 015 Control Unit RCU 016 Standard supply Optional or local supply USB Device 9 USB Mouse 100 230 VAC 1ø 50 60 Hz Transformer 440 VAC 1ø 50 60 Hz Switching Hub HUB 100 Monitor Unit ...

Страница 8: ...formance Monitor PM 32A XN20CF RSB130 XN24CF RSB130 Wave guide Signal cable Sub monitor 1 of ECDIS 8 Sub monitor 2 of ECDIS 8 Control Unit RCU 014 or RCU 015 Control Unit RCU 016 Standard supply Optional or local supply USB Device 9 USB Mouse 100 230 VAC 1ø 50 60 Hz Transformer 440 VAC 1ø 50 60 Hz Switching Hub HUB 100 Monitor Unit 3 MU 190 or MU 231 or MU 270W Intelligent Hub HUB 3000 5 100 230 V...

Страница 9: ... PM 52A SN36CF RSB131 Coaxial cable Signal cable Processor Unit RPU 025 Sub monitor 1 of ECDIS 8 Sub monitor 2 of ECDIS 8 Control Unit RCU 014 or RCU 015 Control Unit RCU 016 Standard supply Optional or local supply USB Device 9 USB Mouse 100 230 VAC 1ø 50 60 Hz Transformer 440 VAC 1ø 50 60 Hz Switching Hub HUB 100 Monitor Unit 3 MU 190 or MU 231 or MU 270W Intelligent Hub HUB 3000 5 100 230 VAC 1...

Страница 10: ...r BB type a monitor unit is prepared by user 4 Characteristics of contact output for Alarm Load current 250 mA Polarity Normally Open 2 ports Normally Close 2 ports Serial I O for alarm is also possible which complies with IEC 61162 1 5 For configurations with 3 or more radars ECDIS FMD 3100 FMD 3200 FMD 3300 connect ed connect via the HUB 3000 For 2 radars HUB 100 can be used Connection to a FMD ...

Страница 11: ... network equipment Radar ECDIS etc Serial LAN2 LAN2 Digital Out 6 Power fail system fail NO 2 NC 2 Digital in ACK in HDG AIS IEC 61162 2 GPS LOG AMS ECDIS IEC 61162 1 Digital Out 6 Power fail system fail NO 2 NC 2 Digital in ACK in Monitor Unit MU 190 MU 231 MU 270W or equivalent for BB model Monitor Unit MU 190 MU 231 MU 270W or equivalent for BB model Select one Select one VDR RPU 025 PROCESSOR ...

Страница 12: ...ow shows those functions which are limited to a specific radar type Available Not available The menus which are not mentioned in the table below are available for all types This manual provides descriptions for all functions in this radar series RADAR MODEL TRANSCEIVER UNIT ANTENNA UNIT Remarks FAR 2218 BB FAR 2318 RTR 105 XN12CF RSB128 XN20CF RSB128 XN24CF RSB128 FAR 2228 BB FAR 2328 RTR 106 FAR ...

Страница 13: ...01 xx ver INSTALLA TION RANGE UNIT ICE MODE SETTINGS For 01 xx ver TT PRESET TT NO For 50 xx ver ALERT I F SETTINGS ALERT OUT 1 2 3 4 DESTINATION LEAVE INTRUSION BAN WATER TEMP ALERT CURRENT RIP DEPTH ALERT TARGET ALARM For 50 xx ver AIS CAPACITY FULL A For 01 xx ver AIS CAPACITY FULL C For 01 xx ver INPUT PORT SETTINGS EPFS EPFS1 INPUT DTM SEL EPFS2 INPUT DTM SEL For 50 xx ver NETWORK SETTINGS VD...

Страница 14: ...CU 015 Trackball type Installation Materials CP03 35201 001 249 860 1 For radiator CP03 35401 001 254 980 1 For RSB no de icer CP03 35403 001 270 070 For RSB w de icer CP03 35500 15M 000 024 096 1 For antenna unit 15 m CP03 35510 30M 000 024 097 For antenna unit 30 m CP03 35520 40M 000 024 098 For antenna unit 40 m CP03 35530 50M 000 024 099 For antenna unit 50 m CP03 37801 001 489 150 1 For RPU 0...

Страница 15: ...15 Trackball type RCU 031 Compact type Installation Materials TBD TBD 1 For radiator TBD TBD 1 For RSB TBD TBD 1 For antenna unit 15 m TBD TBD For antenna unit 30 m TBD TBD For antenna unit 40 m TBD TBD For antenna unit 50 m TBD TBD 1 For RPU 025 TBD TBD 1 For RCU 014 015 TBD TBD 1 For RCU 031 Accessories TBD TBD 1 For RCU 014 TBD TBD 1 For RCU 015 TBD TBD 1 For RCU 031 Spare Parts SP03 17641 001 ...

Страница 16: ... RSB no de icer CP03 35404 001 270 080 1 For RSB w de icer CP03 35500 15M 000 024 096 1 For antenna unit 15 m CP03 35510 30M 000 024 097 For antenna unit 30 m CP03 35520 40M 000 024 098 For antenna unit 40 m CP03 35530 50M 000 024 099 For antenna unit 50 m CP03 37801 001 489 150 1 For RPU 025 CP03 25604 008 539 850 1 For RCU 014 015 Accessories FP03 09850 008 535 610 1 For RCU 014 FP03 09860 001 4...

Страница 17: ...255 430 1 For RSB no de icer CP03 35404 001 270 080 1 For RSB w de icer CP03 35500 15M 000 024 096 1 For antenna unit 15 m CP03 35510 30M 000 024 097 For antenna unit 30 m CP03 35520 40M 000 024 098 For antenna unit 40 m CP03 35530 50M 000 024 099 For antenna unit 50 m CP03 37801 001 489 150 1 For RPU 025 CP03 25604 008 539 850 1 For RCU 014 015 Accessories FP03 09850 008 535 610 1 For RCU 014 FP0...

Страница 18: ...097 For antenna unit 30 m CP03 35520 40M 000 024 098 For antenna unit 40 m CP03 35530 50M 000 024 099 For antenna unit 50 m CP03 37801 001 489 150 1 For RPU 025 CP03 25604 008 539 850 1 For RCU 014 015 CP03 16400 000 086 743 1 w CP03 16401 CP03 16410 000 086 744 Flexible waveguide 20 m w CP03 16411 CP03 16420 000 086 745 Flexible waveguide 30 m w CP03 16411 CP03 16430 000 086 746 Flexible waveguid...

Страница 19: ...na unit 30 m CP03 35520 40M 000 024 098 For antenna unit 40 m CP03 35530 50M 000 024 099 For antenna unit 50 m CP03 37801 001 489 150 1 For RPU 025 CP03 25604 008 539 850 1 For RCU 014 015 CP03 36300 000 025 573 1 Coax cable 20 m CP03 36310 000 025 574 Coax cable 30 m Accessories FP03 09850 008 535 610 1 For RCU 014 FP03 09860 001 419 140 1 For RCU 015 Spare Parts SP03 17641 001 249 740 1 Fuse for...

Страница 20: ...UB 3000 Installation Materials CP03 38000 000 034 321 1 Accessories FP03 12700 000 034 322 1 Name Type Code No Remarks Control Unit RCU 016 Trackball type Junction Box RJB 001 000 083 355 AD Converter AD 100 E Signal Cable Assy S03 9 5 8 8P 008 206 640 For sub monitor of ECDIS 5 m RW 4864 w VH8 connector S03 9 10 8 8P 008 206 650 For sub monitor of ECDIS 10 m RW 4864 w VH8 connector S03 9 15 8 8P ...

Страница 21: ...stand 19 OP26 20 001 139 300 For MU 190 connection Clamp Assembly OP03 182 008 535 620 For RCU 014 Cable Assy DVI D D S LINK 5M 001 133 960 10 Between processor unit and moni tor unit 5 m DVI D D S LINK 10M 001 133 980 10 Between processor unit and moni tor unit 10 m LAN Cable Assembly MOD Z072 020 001 167 880 10 For LAN cable between RPU 025 and HUB 100 2 m MOD Z072 050 001 167 890 10 For LAN cab...

Страница 22: ... Cable Extension Kit OP03 251 1 001 496 600 For RSB 133 OP03 251 2 001 496 610 For RSB 129 OP03 251 3 001 496 620 For RSB 128 High Speed Kit OP03 248 001 496 640 For S band radar PM Installation Kit OP03 254 1 001 505 240 For RSB 133 OP03 254 2 001 505 250 For RSB 129 OP03 254 3 001 505 290 For RSB 128 OP03 260 001 551 760 For RSB 139 Retrofit Cable Kit OP03 255 1 001 505 320 For RSB 129 133 OP03 ...

Страница 23: ...N radar RectangularGuide Clamp OP03 148 008 477 540 FR 9 Termination FR 9 00 001 102 740 Waveguide Drain 03 009 0360 001 351 950 H type Wave guide Clamp CP03 00600 W 008 198 420 E Bend Wave guide RWA 1030 B 107 001 304 640 Thru deck Cable Gland CP03 00702 008 197 350 For S band TR DOWN radar Cable Clamping Fixture 03 011 3228 001 074 670 10 Magnetron Re placement Instruc tion Manual E32 01306 000 ...

Страница 24: ...EQUIPMENT LISTS xxii This page is intentionally left blank ...

Страница 25: ...rc of the horizon from right ahead to 22 5 aft of the beam to either side see the figure below Also individual blind sectors of more than 5 or the total arc of both blind sectors of more than 20 must not occur in the remaining arc Figure 2 Note that any two blind sectors sep arated by 3 or less are regarded as one sector Do not install the antenna where extreme winds may strike the port and starbo...

Страница 26: ...FS A separation of more than two meters is recommended A magnetic compass will be affected if the antenna unit is placed too close to the compass Observe the compass safe distances on page ii to prevent interference to a magnetic compass Do not paint the radiator aperture to ensure proper emission of the radar waves Ground the unit with the ground wire supplied Deposits and fumes from a funnel or ...

Отзывы: