TROUBLESHOOTING YOUR F50-ATS:

In the event of a problem with your F50-ATS, contact a qualified electrician for advice.

COMMON PROBLEMS:

Transfer switch will not switch over from Shore Power to Generator feed.

Possible cause: Bad PCB.

How to check:  Open the transfer Switch lid so the PCB in visible, do not put your hands or 

touch anything parts inside the box.  

Turn on the generator so electric is being fed to the ATS, using a multi meter check for 

correct voltage at the incoming generator wiring terminals.

If the correct power is being fed to the ATS from the Generator the ATS PCB’s the green 

LED illuminated.  After 30 seconds if the contactor does not close 

If the PCB’s green LED is not illuminated while generator voltage is present indicates 

the PCB has been damaged and will need replaced.

Contact your nearest Furrion Dealer, RV OEM or email [email protected]

POSSIBLE CAUSES FOR F50-ATS PROBLEMS

:

INGRESS OF FOREIGN OBJECTS INSIDE ENCLOSURE:

Reasons: 

Poor installation can cause wood chippings, sawdust, metal filings, or other foreign 

matter to enter the case.

Unsuitable mounting position can cause condensation, moisture or dirt to enter the 

enclosure, 

Potential Damage: Contactor does not function properly, burned out coils, Metal particles 

can cause fire or short the PCB.

FLUCTUATING POWER OR POWER SPIKES:

Reasons: 

Lighting strikes,

Unbalance load at park, 

Park Black outs

Utility service at park is undersized or located next to an industrial environment.

Potential Damage: burnt out contactor coils, PCB damage, pitted contacts, further 

damage to the RV.

LOW VOLTAGE POWER SUPPLY:

 

Reasons: 

Bad or corroded electrical connection,

Extension cord length too long 

Operating too much load for power available.

Park power supply insufficient

Potential Damage: Pitted contacts, burnt out contactor coils, further damage to the RV.

GENERATOR FEED

:

Reasons: 

Generator requires maintenance, 

Generator Governors or throttle problems

Generator Auto Start/Stop failure.

Potential Damage: Burnt out contactor coils, PCB damage, pitted contacts, further 

damage to the RV.

 

Содержание ATS series

Страница 1: ...50amp 125 250V Automatic Transfer Switch F50 ATS Furrions ATS is used to safely switch automatically between mutiple power sources...

Страница 2: ...terminals this will start a timer and automatically switch over to generator power supply after a 20 30 second delay which ensures the generator has sufficient time to run up to speed before electrica...

Страница 3: ...LL SMART PLUG FEATURED BELOW GENERATOR 50Amp 125 250 VAC 12KW Generator Configuration 2 Triple power feed same rating This configuration is used when a inverter is added to the system and requires aut...

Страница 4: ...0 20 20 DISTRIBUTION PANEL 1 Input 2 Input 1 F30 ATS Transfer switch Output feed POWER INVERTER MAX 3000W EXAMPLE 3 100 100 50 50 75 75 50 50 50 50 70 70 15 20 20 15 15 20 20 50 50 20 30 20 30 75 75 2...

Страница 5: ...nt of entry or generator output Typical examples of mounting locations are Inside seat or bed compartments Above or behind cabinets Under floor storage compartments etc To mount the ATS box the 4 scre...

Страница 6: ...the box sticker The line out wires will enter the ATS from the opposite side See below diagram for wiring layout Strip 4 of outer jacket from each of the incoming cables Strip of jacket from each of...

Страница 7: ...rom the generator the green LED indicator light on the internal ATS PCB will illuminate the ATS has a 20 30 second time delay before engaging the internal contactor to allow for the generator to warm...

Страница 8: ...N OBJECTS INSIDE ENCLOSURE Reasons Poor installation can cause wood chippings sawdust metal filings or other foreign matter to enter the case Unsuitable mounting position can cause condensation moistu...

Страница 9: ...ption One Using the external lugs which are located on the outside of the box Mounting dimensions for the external lugs are Outer Lugs 189 x 220mm 7 x 8 11 16 7 16 Option Two Using the 4 x internal ho...

Отзывы: