Product Specification
Page 10 of 18
1303090MS01
LA-309 Controlled Atmosphere Infrared Furnace
April 15, 2009
obtain the actual speed of the conveyor itself. Speed accuracy shall be maintained to within ±
0.5%.
9.4.2.2
Temperature control
within the furnace process areas shall be performed by the
controller through PID type control loops. User profile settings shall include temperature set
points, maximum power and PID parameters for each zone of the furnace. Individual type K
thermocouples shall be used to measure the temperature of the zones. Actual power output to
the lamps shall be displayed on the PC monitor. Lamp power shall be controlled by SCR single
phase firing modules individually controlling lamp zones. Phase angle type SCRs shall provide
steady state, true proportioning control of the lamps without flicker. Thermocouple break
monitoring shall be provided.
9.4.2.3
Power.
The PLC shall control the power level of the lamps in each zone,
automatically maintaining each zone at the set point temperature.
9.4.3
. The furnace OI software shall provide a graphical interface for the user to view and
modify the furnace operation: The software shall:
9.4.3.1
depict units in English (
) or metric (
) units as specified at time of order.
9.4.3.2
depict date in US (mm/dd/yyyy), or (dd/mm/yyyy) style if specified at time of order.
9.4.3.3
allow user addition of new users, multiple levels of log-in security and control rights.
9.4.3.4
include online display and modification of current furnace zone temperature and
temperature and power set-points.
9.4.3.5
facilitate storage and retrieval of recipes and offline edit of recipe parameters
including temperature and power set-points, belt speed, PID loop parameters and alarm and
alert levels.
9.4.3.6
allow user to store and display user maintenance items and intervals
9.4.3.7
display and store events, alerts and alarms.
9.4.3.8
allow user to enter, display and store flowmeter set points in recipe files.
10.0 ALARMS
10.1
The controller shall include several standard alarms. Some options, such as the lamp element
monitor, add additional alarms. Basic alarms shall be included as summarized below:
Table 10-1. Basic Alerts and Alarms
Alarm
Audible
Visible
Shutdown
Low Temperature Alert
X
X
High Temperature Alert
X
X
Low Temperature Alarm
X
X
High Temperature Alarm
X
X
X
Transport Speed Error
X
X
Transport Motion Fault
X
X
X
IPS Gas Flow Switch*
X
X
X
* IPS switch sends audible alarm and shuts down the lamps in the event of
loss of process gas into furnace.
10.2
The furnace shall be equipped with four (4) emergency-off (EMO) palm switches that are easy
to locate and reach. There shall be one EMO switch at each end of the unit on each side.
10.3
All side panels covering the computer/UPS and high voltage sections shall be protected with
interlock switches. In the event these panels are opened, all circuitry shall be de-energized,
protecting any service/maintenance personnel.
Содержание LA-309
Страница 5: ...10 004 676 110000 v WARRANTY Warranty goes here ...
Страница 6: ...vi LA 309 Owner s Manual ...
Страница 12: ...Contents xii LA 309 Owner s Manual ...
Страница 20: ...Section 1 1 8 LA 309 Owner s Manual ...
Страница 68: ...Section 3 3 28 LA 309 Owner s Manual ...
Страница 70: ...Section 4 4 2 LA 309 Owner s Manual ...
Страница 72: ...Section 4 4 4 LA 309 Owner s Manual ...
Страница 98: ...Section 5 5 2 LA 309 Owner s Manual ...
Страница 100: ...Section 5 5 4 LA 309 Owner s Manual ...
Страница 106: ...Section 5 5 10 LA 309 Owner s Manual ...
Страница 108: ...Section 5 5 12 LA 309 Owner s Manual ...
Страница 110: ...Section 5 5 14 LA 309 Owner s Manual ...
Страница 112: ...Section 6 6 2 LA 309 Owner s Manual ...
Страница 114: ......
Страница 115: ......
Страница 126: ...Section 7 1 Fiberfrax Cements MSDS 042006 Owner s Manual ...
Страница 139: ...MSDS 2 Fiberfrax Duraboard MSDS 042006 MATERIAL SAFETY DATA SHEETS ...
Страница 140: ...Section 7 2 Fiberfrax Duraboard MSDS 042006 Owner s Manual ...
Страница 153: ...MSDS 3 Fiberfrax Fibers MSDS 042006 MATERIAL SAFETY DATA SHEETS ...
Страница 154: ...Section 7 3 Fiberfrax Fibers MSDS 042006 Owner s Manual ...
Страница 167: ...MSDS 4 Fiberfrax Papers MSDS 042006 MATERIAL SAFETY DATA SHEETS ...
Страница 168: ...Section 7 4 Fiberfrax Papers MSDS 042006 Owner s Manual ...
Страница 181: ...MSDS 5 Magnaform MSDS 050406 MATERIAL SAFETY DATA SHEETS ...
Страница 182: ...Section 7 5 Magnaform MSDS 050406 Owner s Manual ...
Страница 183: ......
Страница 184: ......
Страница 185: ...Section 7 6 RTU Silicone Red Hi Temp 042006 Owner s Manual ...
Страница 186: ...MSDS 6 RTU Silicone Red Hi Temp 042006 MATERIAL SAFETY DATA SHEETS ...
Страница 189: ...Section 7 7 Kaowool Insulation MSDS 050406 Owner s Manual ...
Страница 190: ...MSDS 7 Kaowool Insulation MSDS 050406 MATERIAL SAFETY DATA SHEETS ...
Страница 201: ...Material Safety Data Sheets 7 15 Notes ...
Страница 202: ...Section 7 7 16 Owner s Manual ...
Страница 203: ...8 1 Section 8 APPENDIX A 8 1 TEC10 INTERFACE MODULE CALIBRATION 8 2 675 110001 FURNACE DRIVE MOTOR AND CONTROL ...
Страница 204: ...Section 8 Owner s Manual ...
Страница 206: ...Section 8 Owner s Manual ...
Страница 212: ...iv Operation and Troubleshooting ...
Страница 214: ...vi Operation and Troubleshooting ...
Страница 224: ...Page 10 Operation and Troubleshooting ...
Страница 231: ...9 1 Section 9 APPENDIX B 9 1 EC913 CALIBRATION REPORT 9 2 SERIES EC900 OXYGEN ANALYZERS ...
Страница 232: ...Section 8 Owner s Manual ...
Страница 233: ......
Страница 234: ...Section 8 Owner s Manual ...
Страница 276: ...EC900 Series Operation Manual V 4 1 www systechillinois com Page 39 Appendix 1 Drawing Number B900 176 ...
Страница 277: ...EC900 Series Operation Manual V 4 1 www systechillinois com Page 40 Appendix 2 Drawing Number B 920 043 ...
Страница 278: ...EC900 Series Operation Manual V 4 1 www systechillinois com Page 41 Appendix 3 Drawing Number B 900 180 ...
Страница 279: ...Section 8 Owner s Manual ...
Страница 281: ...MSDS MATERIAL SAFETY DATA SHEETS ...
Страница 282: ...16 Notes ...