background image

AC Transient Voltage Surge Suppression and Extreme Voltage Shutdown

Extreme Voltage Shutdown Indicator 

This LED is normally off. It monitors AC wiring faults – for example, accidental connection to an open neutral from a 300VAC 
or greater feed. When the Extreme Voltage Shutdown (EVS) circuit senses voltages that are so high that operation would be 
impossible, it shuts the power down before damage can occur. Upon initially applying power to these units, the Extreme 
Voltage indicator LED will light if the input voltage is above the extreme voltage cutoff, and power will not be applied to the 
unit’s outlets. If the unit has been operating with an acceptable input voltage and subsequently that voltage exceeds 275V, it 
will shut off power to the outlet and the Extreme Voltage LED will light.   

Protection OK Indicator

Although the Furman SMP circuit assures virtually maintenance free protection from transient voltage spikes and surges, 
nature has a way of occasionally creating electrical forces that are beyond the capabilities of any Transient Voltage Surge 
Suppression device to absorb without some degree of damage.  In the rare instance that this occurs, the blue LED located in 
the center of the front panel will dim, even though AC power is present at the unit’s outputs.  If this happens, some level of 
protection from voltage surges will remain, but the Furman’s clamping voltage rating will be compromised. The unit must be 
returned to Furman Sound, or an authorized Furman Service center for repair. 

NOTE: 

If the mains power is above the high cutoff voltage and has caused the unit to remove power from its outlets, it cannot restore 

power without the operator manually turning the unit off, then on again. Avoid turning the unit back on without first checking the 
source of the problem, and perhaps changing the AC source.

Cable/Satellite Transient Voltage Surge Suppressors 

The SPR-16E i features transient voltage surge suppression for cable or satellite lines utilizing standard coaxial connectors. As 
these surge suppressors are in-line, they will require an additional cable to connect from their output to the control device 
requiring protection.

All in-line surge suppressors feature our exclusive ground contamination-free technology. This aids in eliminating audio 
buzzing, and the video hum-bars that can result from typical in-line suppressors. Further, our cable and satellite suppressors 
are TiVO®/DVR friendly as well as HD-Digital Television ready. Both DC carrier signals as well as high bandwidth signals can 
pass through our circuit. In fact the bandwidth is less than 0.1dB loss at 1GHz!

To connect your cabling to these in-line protectors, simply follow the in and out indications marked next to the Cable - 
Satellite connectors.

NOTE: 

 It is not possible to make an in-line cable or satellite protector “maintenance-free” as we have accomplished with the 230 

VAC line.  This would necessitate limited signal bandwidth that would not allow the signal to pass.  Under extreme conditions, it is 
possible that the surge suppression in one of these devices could sacrifice itself after a catastrophic event.  If the cable or satellite 
signal will no longer pass through our protector, please contact your local service representative, installer or Furman for servicing. 

AC Voltage and Current Meter

Your SPR-16E i contains a true RMS precision incoming AC volt/current meter.  This meter continuously monitors either the 
incoming AC voltage, or the total system AC current draw.  To continuously read current or voltage, simply select the setting 
you wish to monitor by either pressing the voltage/current switch for current, or disengaging the switch for voltage.  Since the 
AC voltage meter indicates incoming voltage, you should not be concerned by readings above or below 230VAC.  

NOTE: 

 For those that mount the SPR-16E i where it could be visible during use, we have included a rear panel mounted dimmer 

switch for the blue digital voltage and current meter.  This allows the user to entirely dim this display when the room lights are 
turned off for optimum video viewing.  

Содержание SPR-16E i

Страница 1: ...OWER VOLTAGE REGULATOR POWER CONDITIONER CONDITIONNEUR D ALIMENTATION ET R GULATEUR DE TENSION STABLE ESTABLE REGULADOR DE VOLTAJE ACONDICIONADOR DE POTENCIA OWNER S MANUAL GUIDE DE L UTILISATEUR MANU...

Страница 2: ......

Страница 3: ...16E i Guide De L Utilisateur SPR 16E i Owner s Manual All content 2007 Furman Sound LLC All Rights Reserved Printed in China ENGLISH Page 4 FRAN AIS Page 10 ESPA OL Page 18 SPR 16E i Manual Del Propie...

Страница 4: ...their full potential With the SPR 16E i home theaters are supplied with constant virtually unwavering AC voltage This assures trouble free service for any environment suffering from unstable power The...

Страница 5: ...e SPR 16E i does not appear to operate normally or exhibits a marked change in performance The SPR 16E i has been dropped or the enclosure damaged The SPR 16E i requires that a safety ground be presen...

Страница 6: ...Outlets should be employed for any components not connected to the Linearly Filtered Video or Linearly Filtered Audio outlet banks Rear Panel Suggested AC Connection Soft Start Continuous Use and Brea...

Страница 7: ...ion for cable or satellite lines utilizing standard coaxial connectors As these surge suppressors are in line they will require an additional cable to connect from their output to the control device r...

Страница 8: ...an determines that the damage did not result from the Occurrence or that no Occurrence in fact took place or Furman determines that the connected equipment was not used under normal operating conditio...

Страница 9: ...z 80 dB from 100Khz 1GHz Linear attenuation curve from 0 05 100 ohms line impedance Outlets 1 linearly filtered outlet 16 amp 7 linearly filtered outlets 4 linearly filtered outlet with additional ult...

Страница 10: ...prolonger son utilisation et de r pondre aux demandes suppl mentaires Cette situation affecte consid rablement le rendement de votre syst me Les amplificateurs de puissance et les caissons d extr mes...

Страница 11: ...xp dition Vous en aurez besoin dans l ventualit d un retour de l unit l usine aux fins de r paration La bo te devrait contenir l unit SPR 16E i un cordon c a amovible un ensemble de montage en b ti un...

Страница 12: ...en retirant les deux 2 vis t te frais e plate situ es dans les coins avant du panneau sup rieur L installation de chaque querre de montage exige trois 3 vis Philips t te cylindrique bomb e incluses d...

Страница 13: ...d une source de 208 ou 240 V c a cette situation survient fr quemment lorsque la prise c a source n est pas une ligne d di e et qu elle a plut t t reli e un fil neutre connect en s rie partir d une b...

Страница 14: ...s de c blodistribution et lignes de signaux num riques par satellite comme nous l avons fait pour la section de 230 V c a Cela n cessiterait une largeur de bande r duite ne permettant pas la transmiss...

Страница 15: ...normales d utilisation ou selon les instructions propos es par le Fabricant de l quipement connect Tous les limiteurs de surtension de Furman doivent tre reli s directement une ligne d alimentation c...

Страница 16: ...att nuation lin aire avec imp dance de ligne de 0 05 100 ohms Prises 1 prises avec technologie de filtrage lin aire 16A 7 prises avec technologie de filtrage lin aire 4 prises avec technologie de filt...

Страница 17: ...17...

Страница 18: ...taje del SPR 16E i los amplificadores y los sub woofers muestran su capacidad al m ximo Con el SPR 16E i los teatros en casa son previstos con un constate en la CA Esto asegura el servicio sin problem...

Страница 19: ...a expuesto a la lluvia o humedad S el SPR 16E i no parece funcionar normalmente o expuesto a un cambio marcado en su funcionamiento Si el SPR 16E i se ha ca do o da ado El SPR 16E i requiere de una co...

Страница 20: ...a de primer SPR 16E i la palanca de la energ a del triturador del panel delantero se debe cambiar a on la caracter stica del suave comienzo estar activado Cuando el SPR 16E i se ha encendido o apagado...

Страница 21: ...tener la unidad de nuevo encendido sin haber comprobado la fuente del problema y quiz s cambiar la fuente de AC Sat lite Supresor de Voltaje El SPR 16E i para las l neas del cable o del sat lite que u...

Страница 22: ...les o de acuerdo con las instrucciones del fabricante para conectar el equipo Todos los protectores Furman se deben conectar correcta y directamente en una l nea de energ a de CA No se permite dos o t...

Страница 23: ...s de l nea impedancia Enchufes 1 enchufes lineales 16A 7 enchufes lineales 4 enchufes lineales con filtro ultras nico para componentes digitales o de video Supresi n transitoria de la oleada del volta...

Страница 24: ...1690 Corporate Circle Petaluma California USA 94954 Phone 707 763 1010 Fax 707 763 1310 www FurmanSound com SPR16EiM_Rev1a...

Отзывы: