SPR-16 E ownER’S manual

and/or CD player would be ideally suited for 
these outlets.

It should be noted that since each of the AC 
bank’s symmetrical outlets are in parallel (for 
instance, two per bank “A”), some component 
power supply noise could potentially “back-
wash” between these units. For this reason 
it is recommended that systems with minimal 
componentry (three units or less, excluding 
the power amplifiers) utilize one “Discrete” 
bank per component. This will maximize 
performance by eliminating inter- component 

AC noise contamination entirely! For systems 

utilizing more componentry, a very high level 
of performance will still be achieved with 
careful routing of component AC cords to the 

SPR-16 E’s three “Discrete” power banks. We 

recommend separating digital processors, 
DVD’s, and CD players from pre-amplifiers, 
tuners, and tape machines. Further, video 
monitors and scalers should ideally be 
separated from audio components. 

Connecting Components to the linear 
Filtering Power Banks

The SPR-16 E’s seven rear panel Linear 

Filtering Power Outlets should be employed 
for any component not connected to the four 

“Digital - Video Component AC Outlets.” These 

outlets still have incredible AC noise filtering to 
maximize system performance.  

Connecting Components to the 16 amp 
High Current outlet 

The SPR-16 E’s high current outlet possesses 

the same Linear Filtering Technology as the 
other 11 outlets, but it can supply 16 amps. 

This higher current IEC outlet is appropriate 

for ultra-high current amplifiers requiring more 
than a 10 amp tap (very rare) or for series 

connection to the Furman IT-Reference 16 E.

 

Soft Start - Continuous use and 
Break-In Time:

When power is first applied to the SPR-16 

E, (the front panel breaker- rocker switch 

must be switched to the “1” position) the Soft 

Start feature is activated. There is an audible 

“clack” when the SPR-16 E is first turned on or 

off. This sound is produced by the Soft Start 
circuit’s 30 Amp relay engaging or disengaging. 

There is virtually nothing in the SPR-16 E’s 

construction, design, or componentry to wear 
over the lifetime of the product, and there is no 
power draw from your electric service meter 
aside from the LED power indicator, and relay 
circuits. For this reason the SPR-16 E may 
be left with its power engaged permanently 
at a cost of pennies per month. This is an 
added benefit, as many audio/videophiles 

find performance improves significantly when 

leaving low-powered components permanently 
charged (turned on). In fact, this is true 
of the SPR-216 E. Though it will function 

flawlessly right from its shipping carton, the 

performance of its circuit parts will improve 
after approximately two weeks of continuous 
use or “break-in.” 

aC Transient Voltage Surge 

Suppression and Extreme 

Voltage Shutdown

Extreme Voltage Shutdown Indicator: 

This LED is normally off. It monitors AC wiring 

faults – for example, accidental connection 
to an open neutral from a 300VAC or greater 
feed. When the Series Multi-Stage Protection 

(SMP) circuit senses voltages that are so 

4

Содержание SPR-16 E

Страница 1: ...SPR 16 E owner s manual...

Страница 2: ...xtensive engineering expertise and robust build quality have answered the challenge of today s corrupted power lines and led to the creation of the SPR 16 E With today s chaotic demands on many munici...

Страница 3: ...the SPR 16 E you will notice far visual images from your system with stunningly focused sound Video presentation will be crisp and colors true with greater gray and black scale definition as well as n...

Страница 4: ...ble cabinet shelf or floor These rubber feet may be easily removed with a standard Philips screw driver when rack mounting adjacent to other components Because of the SPR 16 E s internal shielding pla...

Страница 5: ...can supply 16 amps This higher current IEC outlet is appropriate for ultra high current amplifiers requiring more than a 10 amp tap very rare or for series connection to the Furman IT Reference 16 E...

Страница 6: ...from its outlets it cannot restore power without the operator manually turning the unit off then on again Avoid turning the unit back on without first checking the source of the problem and perhaps ch...

Страница 7: ...e of purchase to complete warranty registration by mail or on line at the Furman website If the purchaser fails to complete the aforementioned registration the warranty period will be reduced to one y...

Страница 8: ...man Surge Protector has been opened improperly installed altered in any way or tampered with Furman determines that the damage did not result from the Occurrence or that no Occurrence in fact took pla...

Страница 9: ...rman s employees or representatives ORAL OR OTHER WRITTEN STATEMENTS DO NOT CONSTITUTE WARRANTIES shall not be relied upon by purchaser and are not a part of the contract for sale or this limited warr...

Страница 10: ...SPR 16 E owner s manual 9...

Страница 11: ...SPR 16 E owner s manual 10...

Страница 12: ...d Contamination Extreme Voltage Shutdown 27 VAC Cable Satellite less than 1dB insertion loss Power Consumption 2 Watts for display and control circuits independent of actual load Outlets 1 linearly fi...

Отзывы: