Furman Q-1311 Скачать руководство пользователя страница 10

10

amplifiers or recording devices, they can rob power and cause distortion while 

adding little, if anything, to sound quality.

The High Cut’s range is 3KHz to 40 KHz. Roll off beyond the cutoff point is at 12 dB 

per octave.

8.  LEVEL CONTROL

Adjusts the overall output volume. The combined effect of the EQ Frequency 

sliders typically results in an increase or decrease of overall output level. The 

Level Control can compensate for this change in level. Compare the level of the 

equalized signal with that of the unequalized signal (bypass button in), and use 

the Level Control to eliminate any difference in levels. 

9.  LEVEL METERS (Q-2152V, Q-1312V)

Each channel of the EQ is equipped with a backlit VU meter. The meter is 

calibrated for “0” level equal to +4 dBu output. 

Rear Panel

10.  POWER CABLE

This cable is used to connect to an AC power source. For North American models, 

this source shall be 115 115VAC; for export models, the source shall be 230VAC.

11.  FUSE HOLDER

This holder contains the AC primary fuse. If the fuse has blown, replace with the 

same size and rating. If the fuse continues to blow, refer servicing to qualified 

technical personnel. 

12.  AC VOLTAGE SELECTOR

Set this switch to match the AC line voltage in your area.

13.  GROUND LIFT SWITCH

In many installations, hum-causing ground loops are formed by the common 

connection of various pieces of equipment to the power line ground, and by 

contact between chassis, as in a rack with metal rails. Sliding the Ground Lift 

switch up completely isolates all signal grounds from the chassis, breaking any 

ground loops. The chassis always remains connected to the ground pin on the 

AC cord for safety and to shield against RF interference. Try both positions of the 

Ground Lift switch, and leave the switch in the position that results in the least 

hum in your system. 

Note: 

The ground lift can be rendered ineffective by 3 pin audio connectors that 

tie pin 1 (signal ground) to the metal shell is optional on all 3 pin connectors, and 

can be removed, if present, by opening up the connector on the cable and 

disconnecting it.

Содержание Q-1311

Страница 1: ...1...

Страница 2: ...nections 6 Q 2312 Front Panel Controls 7 Q 2312 Rear Panel Connections 7 Q 2151 Front Panel Controls 7 Q 2151 Rear Panel Connections 7 Q 2152V Front Panel Controls 8 Q 2152V Rear Panel Connections 8 D...

Страница 3: ...of your Q Series Equalizer This manual covers ve models Q 2151 Dual 15 band single rack space Q 1311 Single 31 band single rack space Q 2312 Dual 31 band double rack space Q 2152V Dual 15 band long th...

Страница 4: ...for your safety If the provided plug does not t into your outlet consult an electrician for replacement of the obsolete outlet 8 Protect the power cord from being walked on or pinched particularly at...

Страница 5: ...VU meter housed in a two rack space chassis It is suitable for the most critical applications The Q 1312V is a single channel 31 band equalizer using long throw 60mm sliders and a highly accurate VU...

Страница 6: ...6 Q 1311 Front Panel Controls Q 1311 Rear Panel Connections Q 1312V Front Panel Controls Q 1312V Rear Panel Connections Q 1311 14 13 10 12 11 Q 1312V 9 14 13 10 12 11...

Страница 7: ...7 Q 2312 Front Panel Controls Q 2312 Rear Panel Connections Q 2151 Front Panel Controls Q 2151 Rear Panel Connections Q 2312 14 13 10 12 11 Q 2151 14 13 10 12 11...

Страница 8: ...convenience it is recommended that the equalizer and any other rack mount equipment be powered through a switchable outlet box such as the Furman PL 8 II Power Conditioner and Light Module The PL 8 I...

Страница 9: ...n bypass mode The stereo Q 2151 Q 2152V and Q 2312 have two of these buttons allowing either channel to be bypassed independently Note that when the Bypass button is activated the Level Control is byp...

Страница 10: ...be 230VAC 11 FUSE HOLDER This holder contains the AC primary fuse If the fuse has blown replace with the same size and rating If the fuse continues to blow refer servicing to quali ed technical perso...

Страница 11: ...into segments or bands each covering a designated frequency range The Q 2151 and Q 2152V utilize 15 bands each covering 2 3 of an octave while the Q 1311 Q 1312V and Q 2312 use 31bands each covering...

Страница 12: ...ystem with a Patch Bay such as the Furman PB 48 Then each EQ channel can be easily patched into as needed Each EQ input output pair should be connected to a vertical pair of jacks on the patch bay The...

Страница 13: ...ges back to Purchaser will be paid by Manufacturer THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNES...

Страница 14: ...gainst damage in shipment and that it is insured We suggest that you save the original packaging and use it to ship the product for servicing Also please enclose a note giving your name address phone...

Страница 15: ...Frequency Response 20Hz 20kHz 0 5dB THD Noise 01 20Hz 40kHz 10dBu IM Distortion SMPTE 0 005 Signal to Noise Ratio 94dB 20kHz Noise Bandwidth Channel Separation 50dB 1kHz Common Mode Rejection 50 1 LIN...

Страница 16: ...16 Furman Sound Inc 1997 South McDowell Blvd Petaluma California 94954 6919 USA Phone 707 763 1010 Fax 707 763 1310 Web www FurmanSound com E mail info FurmanSound com 100104 A...

Отзывы: