Furman IT-Reference 16 E Скачать руководство пользователя страница 4

IT-REFERENCE 16 E owNER’s maNual

   connected to the IT-Reference 16 E.

The IT-Reference 16 E should be serviced by 

qualified service personnel when:

 

   The power supply cord or plug has been  

 

frayed or cut.

 

   Objects have fallen or liquid has spilled into  

 

the unit. 

 

   The IT-Reference 16 E has been exposed to 

     rain or other moisture.

 

   The IT-Reference 16 E does not appear to  

     operate normally, or exhibits a marked 
     change in performance.

 

   The IT-Reference 16 E has been dropped,   

     or the enclosure damaged.

Power source

The power source to which the IT-Reference 
16 E is connected should ideally be adequate 

for use at 16 Amps. Though the system may 
function with a 10 Amp panel circuit breaker, 
nuisance circuit breaker tripping could result 
at your service panel. If your system includes 

multi-channel audio power amplifiers that 

require more than modest power demands, 
a circuit breaker with a rating of at least 16 

Amps (13 in the U.K.), is essential for optimum 

performance. 

Placement

The IT-Reference 16 E is manufactured with 

four rubber feet for placement on any table, 

cabinet, shelf, or floor capable of supporting 

its 37 kg weight. These rubber feet may be 
easily removed with a standard Philips screw 
driver when rack mounting adjacent to other 
components. Because of the IT-Reference 16 
E’s internal shielding, placement or proximity 
to other components is not critical, and the 
IT-Reference 16 E does not produce any 
appreciable heat under standard use. The 
IT- Reference 16 E may also be rack mounted 

in a standard 19” (48 cm) rack by attaching 
the IT-Reference 16 E rack ears. These rack 
ears (contained within the plastic rack kit 

package) mount flush with the back portion 

of the IT- Reference 16 E’s front panel. They 
are attached to the chassis by removing the 

(3) countersunk screws on each forward-

side of the chassis top cover. Each rack ear 
is installed with pan-head Philips screws 
contained within the IT-Reference 16 E rack 
mounting kit. Due to the weight of the 
IT-Reference 16 E (37 kg.), it is recommended 
that placement be at or near the bottom of your 
rack when choosing this mounting option. 

Connections:

aC Cable Routing

Once the IT-Reference 16 E is placed, the 

female end of the AC cord must be plugged 
into the male IEC connector located on the 
lower left hand side of the rear panel (when 
facing the rear panel). Next, the male plug 
must be connected to an appropriate socket. 

This AC cord will carry substantial unbalanced 

AC current, so it should be dressed away 

from critical signal-carrying cables, or at the 

very least, cross them at a 90 degree angle. 

The same is true of the power amplifier AC 

cords when plugged into the IT- Reference 

16 E’s “High Current - Amplifier Power” AC 

filtered outputs. All other components plugged 

into “Discrete Symmetrical Power” outlets (A) 
through (C) have symmetrical balanced AC 

current and will radiate virtually no field; as a 

result of this technology, their placement is not 
critical.  

Connecting Components to the 
symmetrical Power Banks

The IT-Reference 16 E’s “Symmetrical 

3

Содержание IT-Reference 16 E

Страница 1: ...IT REFERENCE 16 E owner s manual...

Страница 2: ...and robust build quality have answered the challenge of today s corrupted power lines and led to the creation of our flagship power conditioner the IT Reference 16 E Today s AC lines are plagued with...

Страница 3: ...remaining true to your system s inherent virtues Installation Unpacking Before unpacking your unit inspect the carton for any obvious severe damage to the box and internal protective materials If int...

Страница 4: ...any appreciable heat under standard use The IT Reference 16 E may also be rack mounted in a standard 19 48 cm rack by attaching the IT Reference 16 E rack ears These rack ears contained within the pl...

Страница 5: ...erformance it is vital that an AC filter possess extraordinarily low impedance and have the capability to pass peak current demands far in excess of the RMS continuous current rating The IT Reference...

Страница 6: ...s circuit parts will improve after approximately two weeks of continuous use or break in Ground Fault Interrupter GFCI The IT Reference 16 E s Discrete Symmetrical Filtered AC outlets incorporate a ba...

Страница 7: ...gh that operation would be impossible it shuts the power down before damage can occur Upon initially applying power to these units the Extreme Voltage indicator LED will light if the input voltage is...

Страница 8: ...able or satellite protector maintenance free as we have accomplished with the 230 VAC line This would necessitate limited signal bandwidth that would not allow the signal to pass Under extreme conditi...

Страница 9: ...sulted from an Occurrence and does not protect against acts of God other than lightning such as flood earthquake war terrorism vandalism theft normal use wear and tear erosion depletion obsolescence a...

Страница 10: ...IT REFERENCE 16 E owner s manual 9...

Страница 11: ...IT REFERENCE 16 E owner s manual 10...

Страница 12: ...Mode 15 dB from 1Khz 3 kHz 40 dB from 3 Khz 100 kHz 80 dB from 100 kHz 1GHz Linear attenuation curve from 0 05 100 ohms line impedance Common Mode 90 dB 10 Hz 50kHz 40 dB 50 kHz 1MHz Transient Voltage...

Отзывы: