aR-15 II Voltage RegulatoR / poweR condItIoneR

liFt (linear Filtering technology)

Unfortunately, traditional AC filter - conditioners 

have been designed for unrealistic laboratory 
conditions.  prior technologies could actu-
ally harm audio and video performance more 
than they help, due to the resonant peaking 
of their antiquated, non-linear designs.  under 
certain conditions, these designs can actually 
add more than 10 dB of noise to the incoming 
AC line!  Furman’s sMp+ with LiFt takes an-
other approach, ensuring optimal performance 

through linear filtering and no leakage to 
ground.  With this exclusive filtration technol

-

ogy, all connected equipment will be free of 
noise and contamination and will operate at 
optimum performance levels.

extreme Voltage shutdown Indicator 

this Led is normally off. it monitors a hazard 
common in the entertainment industry: wiring 
faults – for example, accidental connection 
to 220VAC where 120VAC is expected, or an 
open neutral from a 208 or 240VAC feed. the 
series ii sMp+ circuit senses voltages that 
are so high that operation would be impossible 
and shuts the power down before damage 
can occur.  upon initially applying power to 
these units, the extreme Voltage indicator 
Led will light if the input voltage is above the 
extreme voltage cutoff, and power will not be 
applied to the unit’s outlets. if the unit has been 
operating with an acceptable input voltage 
and subsequently that voltage exceeds 145-
150V, it will shut off power to the outlet and the 
extreme Voltage Led will light.  

note:

 if the mains power is above the high 

cutoff voltage and has caused the unit to 
remove power from its outlets, it cannot restore 
power without the operator manually turning 

the unit off, then on again. Avoid turning the 

unit back on, without first checking the source 

of the problem, and perhaps changing the AC 
source.

protection oK Indicator

Although the Furman sMp+ circuit assures 
virtually protection from transient voltage 
spikes and surges, nature has a way of 
occasionally creating electrical forces that are 
beyond the capabilities of 

any

 tVss device to 

absorb without some degree of damage.  in 
the rare instance that this occurs, the green 

“Protection OK” LED indicator located on your 

front panel will dim.  if this happens some level 
of protection from voltage surges will remain, 
but the Furman’s clamping voltage rating will 
be compromised. the unit must be returned 
to Furman sound, or an authorized Furman 
service center for repair. 

Fuses and cIRcuIt BReaKeRs

there is one fuse and one circuit breaker in the 
AR-series. in the event that the unit appears to 
be completely dead (neither the power switch 
nor any Led’s light up), unplug the power cord 
and the load and check the breaker. if the cir-
cuit breaker is tripped, a white button will pop 
up. push it back in to reset it. the purposes of 
these circuit protection devices are:

1. A 15 amp thermal circuit breaker is acces-

sible at the rear panel without removing the 
unit from the rack. this breaker will trip if the 
unit’s 15 amp capacity is exceeded at any 
time.

2. A fast-blow 1/4 amp fuse is located inside 

the unit. this fuse will blow if the unit has 
been connected to a voltage that is above 
the range of the extreme Voltage shut-
down circuitry. to replace it, the unit must 

3

Содержание elite AR-15

Страница 1: ...AC Line Voltage Regulator and power conditioner AR 15 II Voltage Regulators...

Страница 2: ...to read this manual carefully WARNING To reduce the risk of electrical shock do not expose this equipment to rain or moisture Dangerous high voltages are present inside the enclosure Do not remove the...

Страница 3: ...vels depending on the requirements of the equipment This stable voltage protects equipment and allows optimal performance See graphs on the back page The AR 15 II has eight outlets on the rear panel a...

Страница 4: ...ains power is above the high cutoff voltage and has caused the unit to remove power from its outlets it cannot restore power without the operator manually turning the unit off then on again Avoid turn...

Страница 5: ...the rack s tapped holes this is not a metric size In particular beware of 10 24 screws which may fit if forced but which will strip the threads To avoid marring the front panel finish use plastic was...

Страница 6: ...nd de grade wiring insulation They are an unavoid able component of electric power They are caused unpredictably by electric motors switch ing on or off on the premises or outside utility company main...

Страница 7: ...defects in products or components not manufactured by Manufac turer or against damages resulting from such non Manufacturer made products or compo nents This warranty shall be cancelable by Manufactur...

Страница 8: ...s protected by a limited three year warranty covering defects in materials and workmanship Furman Sound LLC 1690 Corporate Circle Petaluma CA 94954 6919 USA Phone 707 763 1010 Fax 707 763 1310 Web www...

Отзывы: