background image

ELITE 15 PF OWNER’S MANUAL

4

components.  Placement or proximity to other 

components is not critical, and the Elite-15 

PF does not produce any appreciable heat 

under standard use.  The Elite-15 PF may 

also be rack mounted in a standard 19” rack 

by attaching the Elite-15 PF rack ears.  These 

rack ears (contained within the plastic rack kit 

package) mount fl ush with the back portion 

of the Elite-15 PF’s front panel.  They are 

attached to the chassis by installing each rack 

ear with (3) pan-head Philips screws contained 

within the Elite-15 PF rack mounting kit.  The 

third screw used for each rack ear is for the 

center hole, located towards the rear and aids 

in stabilizing the unit when rack mounted. 

Connection:

AC Cable Routing

Once the Elite-15 PF is placed, its AC cord’s 

female end must be plugged into the male IEC 

connector located on the lower left hand side 

of the rear panel (when facing the rear panel).  

Next the male Edison plug must be connected 

to an appropriate socket (see current rating 

recommendation above).  

Connecting Components to the Digital - 

Video Component AC Outlet Banks

The Elite-15 PF’s four “Digital - Video 

Component AC Outlets” should be employed 

for critical video components such as DVD 

players, projectors, plasma, or LCD video 

screens.  When employing the Elite-15 PF for 

a 2-channel audio system, a pre-amplifi er and 

or CD player would be ideally suited for these 

outlets.  

Connecting Components to the Linear 

Filtering Power Banks

The Elite-15 PF’s four rear panel and one front 

panel “Linear Filtering Power Outlets” should 

be employed for any component not connected 

to the “Digital - Video Component AC Outlets,” 

with the exception of receivers, power 

amplifi ers and powered sub-woofers.  These 

outlets still possess exceptional AC noise 

fi ltering to maximize system performance. 

Connecting Components to the High 

Current Power Amplifi er Banks

All power amplifi ers, receivers and powered 

sub-woofers should be connected to these four 

outlets.

Many Audiophile and premium Home Theater 

systems will have combined continuous 

current demands below 15 Amps.  It is rare, 

in fact, for large power amplifi ers to draw 

more than 4 Amps continuously.  For superior 

performance, it is vital that an AC fi lter possess 

extraordinarily low impedance, and have the 

capability to pass peak current demands far in 

excess of the RMS (continuous) current rating.  

The Elite-15 PF was designed to more than 

meet this demand.  Additionally, our Power 

Correction Circuitry effectively creates a 

current reserve in excess of 45 amps peak 

up-charge that is cleaner and faster than a 

dedicated line from your local power station.  

This feature eliminates any concern towards 

the current compression that can result from 

typical power conditioners, and the peak 

power reservoir benefi ts any power amplifi ers 

performance dramatically.  

Note about Power Factor Correction and 

Current Consumption 

When power correction technology is 

employed with even the most sophisticated 

circuit breakers, it effectively adds to the 

perceived current load. Though the Elite-15 

PF was designed for steady 15 Amp operation, 

Содержание ELITE 15 PF

Страница 1: ...ELITE 15 PF OWNER S MANUAL...

Страница 2: ...ity Series Multi Stage Protection Plus for virtually maintenance free AC surge suppression Zero ground contamination circuitry protects critical digital components Ultrasonic filtering isolates digita...

Страница 3: ...of day For the rst time you will see and hear your theater or audio system as it should be uncompromised Another critical feature is our exclusive Series Multi Stage Protection Plus This virtually ma...

Страница 4: ...lease read and observe all of the safety and operating instructions before the Elite 15 PF is operated Retain these instructions for future reference Do not disassemble or modify in any way No user se...

Страница 5: ...Power Banks The Elite 15 PF s four rear panel and one front panel Linear Filtering Power Outlets should be employed for any component not connected to the Digital Video Component AC Outlets with the...

Страница 6: ...circuit is turned off via an internal micro switch Whether the light tubes are retracted or nearly ush with the front panel there will be no appreciable heat regardless of dimmer setting due to the e...

Страница 7: ...thout rst checking the source of the problem and perhaps changing the AC source Telco Satellite Cable Transient Voltage Surge Suppressors The Elite 15 PF features transient voltage surge suppression f...

Страница 8: ...Audio Pre Ampli er V C R or V C R or H D Hard Drive Cable Cable Satellite Protectors the incoming and out going cable from the Elite 15 PF Connect the incoming connector to the component that formerl...

Страница 9: ...ly by the Purchaser Damaged equipment must remain available for inspection until the claim is nalized The Connected Equipment Warranty is also in effect for a period of three years unless the Purchase...

Страница 10: ...his Limited Warranty or otherwise shall Furman be liable for incidental special or consequential damages Furman s employees or representatives ORAL OR OTHER WRITTEN STATEMENTS DO NOT CONSTITUTE WARRAN...

Страница 11: ...ELITE 15 PF OWNER S MANUAL 10...

Страница 12: ...137 VAC Telco Cable Satellite less than 1dB insertion loss Power Consumption 12 Watts for display and control circuits independent of actual load Outlets 1 linearly ltered outlet front panel 2 linear...

Отзывы: