FunkTronic Commander Zweitbesprechung O Скачать руководство пользователя страница 6

czbo_a_eng (11.09.2012)

- 6 -

Kompetent für Elektroniksysteme

czbo_a_eng (11.09.2012)

- 7 -

Kompetent für Elektroniksysteme

Jumpers and Potentiometers in the Handset

If jumper JP1 is set the microphone output delivers 5 mV, otherwise 500 mV. The microphone level 

is adjusted with R11. R3 adjusts the level of the earphone.

Jumper Functions (continued)

 

Jumper  Function 

          ex Factory

 

JP10 

closed -> hook - (pin 8) connected to GND 

 

 

open -> hook - (pin 8) separated from GND 

 

 

open / not in use  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  default

 

JP11 

open -> microphone level 80mV at 600 ohm

 

 

closed -> microphone level 500mV at 200 ohm - - - - - - - - - - - - - - - - - -  default

 

 

JP12 

open -> TX_REF must be connected externally - - - - - - - - - - - - - - - - - - default

 

 

top -> TX_REF (pin 4) connected to GND (pin 5)

 

 

bottom -> TX_REF (pin 4) connected to +12V (pin 10)