2-3-7
PDMTR2
R31 -75V (-Vy)
R30 +115V (Vscw)
Mis-discharge
*Mis-discharge
FLOW CHART NO.8
Confirms whether the connector is connected properly.
Yes
No
Yes
Replace the LVDS CTRL B/D unit.
Are the Y SUS B/D unit and Z SUS B/D unit signal
cables normal?
No
Yes
Check that the specific voltage is input to the following
point.
Check Y SUS B/D unit, Z SUS B/D unit IPM fail.
No
Replace the Y SUS B/D unit.
Replace the Y SUS B/D unit or Z SUS B/D unit.
Yes
Replace Y DRV UPPER B/D unit or Y DRV LOWER
B/D unit.
No
Y DRV
UPPER
B/D unit
Normal diode value.
(In case of Panasonic
IC=1.035)
Defective diode value=0.018
*It is different from each IC Maker.
(In case of TI IC=0.6~0.7)
P11
GND
Sus-out
Vs
ER-DN
ER-COM
ER-UP
Check diode value of P11 on Y DRV UPPER B/D unit
and P9 on Y DRV LOWER B/D unit.
Forward : test 1 GND(+) , Sus-out(-)
test 2 Sus-out(+),Vs(-)
test 3 ER-DN(-),ER-COM(+)
test 4 ER-COM(-),ER-UP(+)
when each 4 TEST Diode value is over 0.4V
Reverse : test 1 GND(-) , Sus-out(+)
test 2 Sus-out(-),Vs(+)
test 3 ER-DN(+),ER-COM(-)
test 4 ER-COM(+),ER-UP(-)
when each 4 TEST Diode value is infinity
Y SUS B/D unit.
Refer to FLOW CHART NO.3 (No display (Y SUS B/D unit)).
Содержание F42PDME
Страница 5: ...1 1 2 L0605SP DIMENSIONS 1314 920 1 600 907 47 393 77 120 518 4 83 6 97 692 ...
Страница 18: ...1 5 3 L0605DC Fig 1 1 Back Cabinet S 1 S 2 S 2 S 2 S 2 S 1 S 1 S 1 S 1 S 1 Fig 2 2 Rear Cabinet S 3 S 3 S 3 ...
Страница 23: ...1 5 8 L0605DC 25 Stand Unit S 26 S 26 Fig 8 ...
Страница 27: ...1 5 12 L0605DC Clamper Clamper Fig 13 Cables on the Filter CBA Filter CBA Earth Clamper CN801 ...
Страница 52: ...1 9 21 Analog CBA Bottom View 1 9 22 BL0600F01013 1 ...
Страница 53: ...Switch CBA Top View Switch CBA Bottom View 1 9 23 1 9 24 BL0600G04013 2 ...
Страница 56: ...TP2037 WF4 TP2038 WF5 Digital CBA Bottom View 1 9 29 1 9 30 BL0600G04013 1 ...
Страница 88: ...2 5 1 L0605PCEX 1 8 4 3 2 7 6 5 EXPLODED VIEWS OF PDP MODULE ...
Страница 90: ...F42PDME L0605UF 2004 12 13 ...