![FUNAI D8A-M1000DB Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/funai/d8a-m1000db/d8a-m1000db_service-manual_2345788012.webp)
1-5-1
E8G00PFS
PREPARATION FOR SERVICING
How to Enter the Service Mode
About Optical Sensors
Caution:
An optical sensor system is used for the Tape Start
and End Sensors on this equipment. Carefully read
and follow the instructions below. Otherwise the unit
may operate erratically.
What to do for preparation
Insert a tape into the Deck Mechanism Assembly and
press the PLAY button. The tape will be loaded into
the Deck Mechanism Assembly. Make sure the power
is on, connect TP501 (S-INH) to GND. This will stop
the function of Tape Start Sensor, Tape End Sensor
and Reel Sensors. (If these TPs are connected before
plugging in the unit, the function of the sensors will
stay valid.) See Fig. 1.
Note: Because the Tape End Sensors are inactive, do
not run a tape all the way to the start or the end of the
tape to avoid tape damage.
Q504
Q503
TP501 S-INH
Fig. 1
Содержание D8A-M1000DB
Страница 34: ...1 12 6 E8GA0SCM4 Main 4 7 Schematic Diagram VCR Section...
Страница 35: ...1 12 7 E8GA0SCM5 Main 5 7 Schematic Diagram VCR Section...
Страница 36: ...1 12 8 E8GA0SCM6 Main 6 7 Schematic Diagram VCR Section...
Страница 37: ...1 12 9 E8GA0SCM7 Main 7 7 DVD Open Close Schematic Diagram VCR Section...
Страница 39: ...1 12 11 E8GA0SCJ Jack A Schematic Diagram VCR Section...
Страница 41: ...1 12 13 E8GA0SCD2 DVD Main 2 3 Schematic Diagram DVD Section...
Страница 42: ...1 12 14 E8GA0SCD3 DVD Main 3 3 Schematic Diagram DVD Section...
Страница 68: ...D8A M1000DB D8D M1000DB E8GA0ED 4ED 2007 04 10...