1-3-3
NOTE_1
2. Installation
(1) Using desoldering braid, remove the solder from
the foil of each pin of the flat pack-IC on the CBA so
you can install a replacement flat pack-IC more
easily.
(2) The “
I
” mark on the flat pack-IC indicates pin 1.
(See Fig. S-1-7.) Be sure this mark matches the 1
on the PCB when positioning for installation. Then
presolder the four corners of the flat pack-IC. (See
Fig. S-1-8.)
(3) Solder all pins of the flat pack-IC. Be sure that none
of the pins have solder bridges.
Instructions for Handling
Semi-conductors
Electrostatic breakdown of the semi-conductors may
occur due to a potential difference caused by electro-
static charge during unpacking or repair work.
1. Ground for Human Body
Be sure to wear a grounding band (1M
Ω
) that is prop-
erly grounded to remove any static electricity that may
be charged on the body.
2. Ground for Workbench
Be sure to place a conductive sheet or copper plate
with proper grounding (1M
Ω
) on the workbench or
other surface, where the semi-conductors are to be
placed. Because the static electricity charge on cloth-
ing will not escape through the body grounding band,
be careful to avoid contacting semi-conductors with
your clothing.
Fig. S-1-6
Fine Tip
Soldering Iron
CBA
Flat Pack-IC
Tweezers
Fig. S-1-7
Example :
Pin 1 of the Flat Pack-IC
is indicated by a " " mark.
Fig. S-1-8
Presolder
CBA
Flat Pack-IC
<Incorrect>
CBA
Grounding Band
Conductive Sheet or
Copper Plate
1M
Ω
1M
Ω
<Correct>
CBA
Содержание 29B-250
Страница 34: ...1 8 21 1 8 22 Jack CBA Top View Jack CBA Bottom View BHG470F01014C...
Страница 42: ...1 13 1 HG242FEX EXPLODED VIEWS Front Panel 29B 250 29B 750 A1X A1X...
Страница 44: ...1 13 3 HG242PEX Packing Some Ref Numbers are not in sequence X2 X3 X20 X1 X4 S1 Unit S3 A14 S2 S2 S9...
Страница 79: ...29B 250 29B 750 HG242BD HG454BD 2004 08 04...