background image

8

13 mm x12

13 mm x12

HY

LO

M

AR

LG 90

LG 0

LG 180 LG 270

LG 90

LG 0

LG 180

LG 270

LG 90

LG 0

LG 180

LG 270

LG 90

LG 0

LG 180 LG 270

Manual

FUMEX FBE 

1100

4.3.3 Change of configuration

Take care when installing/uninstalling motor 
packages so that fan wheels are not damaged.
The motor package must always be installed  
so that the cable connection is facing down-
wards after installation.
When installing motor packages, apply 
liquid gasket for sealing between the motor 
plate and fan housing. Fumex recommends 
the 

HYLOMAR

 brand.

Procedure

Upon modification of configuration, refer to 

Fig. 4

 and 

Fig. 5

.

Fig. 4 

Fig. 5 

Fig. 6 

Fig. 8 

Fig. 9 

4.3.4 Possible configurations

LG 0

LG 90

LG 180

LG 270

Fig. 7 

Содержание FBE 1100 LG 0

Страница 1: ...FBE 1100 Manual ...

Страница 2: ...manual 3 1 2 Declaration 3 1 3 Warranty 3 1 4 Manufacturer 3 2 Safety 4 2 1 General 4 2 2 Protective equipment 4 2 3 General warnings information 4 3 Product Description 5 3 1 Serial number product name 5 3 2 Labels and safety signs 5 3 3 Areas of Use 6 3 4 Design 6 3 5 Function 6 4 Preparation for use 7 4 1 Transport storage 7 4 2 Electrical equipment 7 4 3 Assembly installation 7 4 3 1 Unpacking...

Страница 3: ... being voided The warranty period is one year from the date of pur chase and covers the product and its constituent parts All manufacturing defects are covered by the warranty FUMEX replaces defective parts in accordance with NL 17 FUMEX is not liable for any consequential or incidental damage or any loss of income as a result of or in con nection with the warranty case The onus is on the buyer to...

Страница 4: ...icky dust must not be sucked into the fan If this occurs pre filtration must be used or regular cleaning carried out All work on the machine must be carried out by certified and authorised personnel For maintenance work where contact with dust occurs personal protective equipment such as safety glasses respiratory protec tion and safety gloves must be worn The surface on which the machine is insta...

Страница 5: ... Frequency ErP n ErP cat ErP N www fumex com 1 2 3 1 2 3 Manual FUMEX FBE 1100 3 Product Description 3 1 Serial number product name Refer to the product nameplate 3 2 Labels and safety signs Safety signs that are missing or illegible must be replaced before the machine is used According to Fig 1 1 Fumex logotype 2 Nameplate 3 Motor rotation arrow Fig 1 ...

Страница 6: ... Design See Fig 2 1 Fan housing 2 Outlet 3 Outlet grille 4 Lifting eye 5 Motor plate 6 Motor 7 Cooling air intake 3 5 Function Air is sucked through the inlet cone 13 Fig 2 to the center of the fan wheel 12 The air is then sucked through the fan wheel and evacuated through the fan outlet 2 Fig 2 8 Cooling fan 9 Lifting eye motor 10 Junction box 11 Inlet 12 Impeller 13 Inlet cone ...

Страница 7: ...ng from frequency converters If control devices e g frequency converters are used the manufacturer s recommenda tions to avoid interference are followed For example EMC protective earth cable length cable shielding etc The choice of cable and cable area must comply with the national requirements applicable to fixed installa tions For electrical installation see Section 10 2 Circuit diagram electro...

Страница 8: ...o that fan wheels are not damaged The motor package must always be installed so that the cable connection is facing down wards after installation When installing motor packages apply liquid gasket for sealing between the motor plate and fan housing Fumex recommends the HYLOMAR brand Procedure Upon modification of configuration refer to Fig 4 and Fig 5 Fig 4 Fig 5 Fig 6 Fig 8 Fig 9 4 3 4 Possible c...

Страница 9: ...r and does not require drainage as the outlet is the lowest point Suitable in the event of condensation problems On roofs At locations with heavy precipitation founda tions must be built on site See Fig 10 Fig 10 Fig 11 Fig 12 On facades Wall mounting on bracket according to Fig 11 optimises pressure drops on the inlet side 4 3 6 Installation The fan is designed for installation in an industrial p...

Страница 10: ...x4 2 x2 620 70 50 650 Manual FUMEX FBE 1100 4 4 Accessory installation Accessories ordered separately Refer to Chapter 11 Accessories Spare Parts 4 4 1 Flexible duct FBD 750 Fig 13 Fig 14 4 4 2 Transition FBO 1100 4 4 3 Mounting rail FBM 1100 Fig 15 ...

Страница 11: ...pping the fan As the speed decreases you can see which way the motor is rotating through the cooling air intake pos 7 Fig 2 If the direction of rotation is incorrect the phase coupling in the motor terminal block is reversed 3 Check the rotational direction again 4 Turn off the fan The fan is now ready for operation 6 Operation The fan motor generates heat and is equip ped with a cooling fan pos 8...

Страница 12: ...ure that all moving parts are secured to prevent unintentional movement 8 1 Cleaning The product should be cleaned with clean cloths and neutral detergents to avoid damage MAINTENANCE SCHEDULE Interval Item Inspection module Maintenance instructions Date When necessary 1 1 Fan Clean exterior See section 8 1 Cleaning Every six months 2 1 Electrical equipment Check all electrical equipment for visib...

Страница 13: ...ning and disassembly of the product may only be done by authorised personnel wearing protective gear The handling and correct removal of the various types of materials must be in accordance with the applicable legal requirements Please contact FUMEX if you have any questions about the various types of waste ...

Страница 14: ...ncy 50 Hz Power 11 kW Current 19 6 A Speed 2950 rpm Enclosure class IP55 Sound level Lp 94 dB A Temperature limits Max operating temperature 80 C Ambient temperature 20 C till 40 C Transport storage temperature 25 C till 60 C Max humidity 80 Sound pressure level 1 meter from fan at hemispherical sound propagation in free field 10 Technical information ...

Страница 15: ...L1 L2 L3 PE 400V 3 D U1 Z2 V1 U2 Z1 V2 L1 L2 L3 PE 690V 3 Y U1 Z2 V1 U2 Z1 V2 MA1 5 4 3 2 1 8 7 6 9 11 10 13 14 12 17 16 15 18 Manual FUMEX FBE 1100 10 2 Circuit diagram electronics 10 3 Exploded view drawing ...

Страница 16: ...lar to round coupling Fig 17 Safety switch SSB 1100 With lockable toggle Two M25 penetrations included Fig 22 Fig 23 Fig 24 Safety switch SSB 1100 EMC For operation via frequency converter Copper sheathed with lockable toggle Two M25 bushings included Contactor SKO 3 pin contactor with overcurrent relay for manual reset The overcurrent relay has phase loss protection Used in together with external...

Страница 17: ...17 Manual FUMEX FBE 1100 12 Notes ...

Страница 18: ...18 Manual FUMEX FBE 1100 ...

Страница 19: ...19 Manual FUMEX FBE 1100 ...

Страница 20: ...X SUPPLIES EXTRACTION ARMS VEHICLE EXHAUST EXTRACTION FANS FILTERS CONTROLS WORKSHOP EQUIPMENT Verkstadsvägen 2 93161 Skellefteå Sweden Tel 46 910 361 80 Fax 46 910 130 22 E mail info fumex se www fumex com ...

Отзывы: