7
Relay activation jumper
24 volt start connector
RELAY ACTIVATION PROCEDURES FOR FA1 UNITS
1. Remove all power sources from FA1 unit
2. Locate eight screws securing cabinet bottom panel
3. Remove all and gently pry bottom panel loose
CAUTION
Do not work on panel with power applied
4. Locate relay activation Jumper on rear of control panel. (Small plastic rectangle)
5. Gently remove jumper by pulling cap off pins. Shorting cap should be installed over a single pin for
storage and to prevent loss of cap.
Once the jumper has been removed the unit will only start by applying the proper
voltage to the start stop relay. When the unit is running the on and off switch can
be used as long as start relay has power.
6. Reinstall bottom panel and screws
7. Apply power to start relay (see wiring diagram for your unit)