- 17 -

Communication protocol

1.1 Overview

This product uses Modbus-RTU communication protocol, RS485 interface, Modbus protocol defines check code, data sequence, 
etc., these are all necessary for specific data exchange. Modbus protocol uses master-slave acknowledgment connection 
﹙half duplex﹚ on one communication line, this means that the signal is transmitted in the opposite direction on a separate 
communication line. First, the signal of the host computer is addressed to a unique terminal device ﹙slave﹚, then, the response signal 
sent by the terminal device is transmitted to the host in the opposite direction.
Modbus protocol only allows communication between host ﹙PC, etc.﹚ and terminal device, and does not allow data exchange 
between independent terminal devices, so that each terminal device does not occupy the communication line when they initialize, 
but only responds to the inquiry signal reaching the local machine.

1.1.1

  Transfer method

 

Information transmission is asynchronous, and the communication information transmitted between the master and the slave is 
in bytes, including 1 start bit, 8 data bits ﹙the smallest valid bit is sent first﹚, no parity, 1 stop bit.

1.1.2 

Information frame format

Adress code

Function code

Data area

CRC check code

1 byte

1 byte

n bytes

2 bytes

 

Address code:

 The address code is composed of one byte ﹙8-bit binary code﹚ at the beginning of the frame, and the 

decimal is 1 to 255. These bits indicate the address of the user-specified terminal device that will receive the host data from 
it. The address of each terminal device must be unique, and only the addressed terminal will respond to the query containing 
the address. When the terminal sends back a response, the slave address data in the response tells the host which terminal is 
communicating with it.

 

Function code: 

The function code tells the terminal which terminal is performing what function. The following table lists the 

function codes used in this series of instruments, as well as their meaning and function.

 

Data area: 

The data area contains the data required by the terminal to perform a specific function or the data collected by 

the terminal in response to the query. The content of these data may be numeric, reference address or set value. For example, 
the function code tells the terminal to read a register, and the data area needs to indicate which register to start and how 
many data to read. The embedded address and data vary according to the type and the different contents between the 
slaves.

 

CRC check code:

 The error check field ﹙CRC﹚ occupies two bytes and contains a 16-bit binary value. The CRC value is 

calculated by the transmitting device and then appended to the data frame. The receiving device recalculates the CRC value 
when receiving the data, and then compares it with the value in the received CRC field. If the two values are not equal, 
it occurs error.

1.2 Read registers data enumeration

This feature allows the user to obtain data and system parameters collected 
and recorded by the device. The host can read one or more register values 
and can read up to 12 register values at a time ﹙cannot exceed the defined 
address range﹚.

The following example is the basic data collected 
from machine-readable 3 from the 01 ﹙the data 
frame takes up 2 bytes per address﹚ output voltage, 
output current, output frequency, where the output 
voltage address is 0001H, the output current The 
address is 0002H, and the address of the output 
frequency is 0003H.

Indicate

 

Output voltage ﹙V﹚: Convert 0x00+0xE3 to decimal equal to 227
Output current ﹙A﹚: Convert 0x00+0xE6 to decimal equal to 230/100=2.3
Output frequency ﹙Hz﹚: Convert 0x00+0x32 to decimal equal to 50

Slave address

1-255

Function code

0x03

Start register address high

0x00

Start register address low

0-23

Register length high

0x00

Register length low

1-12

CRC Check low
CRC Check high

Slave address

0x01

Function code

0x03

Start register address high

0x00

Start register address low

0x01

Register length high

0x00

Register length low

0x03

CRC Check low

0x54

CRC Check high

0x0B

Slave address

0x01

Function code

0x03

Register length

0x06

Register high

0x00

Register low

0xE3

Register high

0x00

Register low

0xE6

Register high

0x00

Register low

0x32

CRC Check low

0x84

CRC Check high

0x81

Содержание PDA1200SS

Страница 1: ...5VDC 2 1A PDA500SS PDA700SS PDA1200SS PDA2000SS Convertidor DC AC Power inverter DC AC Manual de instrucciones p gina 3 User manual page 12...

Страница 2: ......

Страница 3: ...enos 20 minutos y acuda a un m dico de inmediato 1 2 2 Nunca fume o provoque chispas o llamas en los alrededores de bater as o motores 1 2 3 No deje caer herramientas met licas sobre la bater a Las ch...

Страница 4: ...idor POWER indicaci n de potencia RXD indicaci n de recepci n de datos TXD indicaci n de transmisi n de datos Orificio para montaje Puerto de comunicaci n Inversor de onda sinusoidal pura de 3000W Inv...

Страница 5: ...igurar los par metros y el icono 2 parpadea para configurar el c digo de interfaz Presione UP y DOWN para ajustar los par metros despu s presione SET OK para confirmar el ajuste Si desea restablecer l...

Страница 6: ...e protecci n por tensi n baja 01 12V Por defecto 10 5 Ajuste 10 0 11 0 24V Por defecto 21 0 Ajuste 20 0 22 0 48V Por defecto 42 0 Ajuste 40 0 44 0 Valor de recuperaci n de tensi n baja 02 12V Por defe...

Страница 7: ...hacer clic en Start All Programs PX Monitoring System V1 1 la interfaz es como sigue Despu s de iniciar sesi n la interfaz de monitoreo es la siguiente Doble clic en para instalar Complete el nombre d...

Страница 8: ...realizar una funci n espec fica o los datos recopilados por el terminal en respuesta a la consulta El contenido de estos datos puede ser num rico direcci n de referencia o un valor establecido Por ej...

Страница 9: ...ro alto Registro bajo Palabra 0002 Corriente de salida Registro alto registro bajo 10 Palabra 0003 Frecuencia de salida Registro alto Registro bajo Palabra 0004 Valor de retardo de reinicio Registro a...

Страница 10: ...versor de onda sinusoidal pura Esta garant a es nicamente v lida para este aparato no se reparar o reemplazar n los aparatos que hayan podido ser da ados como consecuencia del mal uso del convertidor...

Страница 11: ......

Страница 12: ...old water for at least 20minutes and get medical attention immediately 1 2 2 Never smoke or allow a spark or flame in vicinity of battery or engine 1 2 3 Do not drop a metal tool on the battery The re...

Страница 13: ...low indicator of converter POWER power indication RXD reception indication TXD data transmission indication Mounting hole Communication port Pure sine wave inverter 3000W Pure sine wave inverter 4000W...

Страница 14: ...parameters then press SET OK to confirm the adjustment If re set the parameter short press SET to make Icon 1 flashing Pressing the ESC to cancel this step and switch to next setting interface direct...

Страница 15: ...10 5 Setting 10 0 11 0 24V Default 21 0 Setting 20 0 22 0 48V Default 42 0 Setting 40 0 44 0 Undervoltage recovery value 02 12V Default 12 0 Setting 11 5 12 5 24V Default 24 0 Setting 23 0 25 0 48V D...

Страница 16: ...on converter and PC click Start All Programs PX Monitoring System V1 1 the interface is as follows After startup login monitoring interface is as follows Double click to install enter the interface as...

Страница 17: ...a area contains the data required by the terminal to perform a specific function or the data collected by the terminal in response to the query The content of these data may be numeric reference addre...

Страница 18: ...e Register high register low Word 0002 Output current Register high register low 10 Word 0003 Output frequency Register high register low Word 0004 Restart delay value Register high register low Word...