1.  IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT:

 Read and save this owner’s guide for future reference.

This chapter contains important safety and installation instructions for our PDA series digital inverters. Each time, before using the 
power inverter, read all instructions and cautionary marking on provided with inverter and all appropriate sections of this guide.

 

Danger

ELECTRICAL SHOCK HAZARD 

• Do not expose the inverter to rain, snow, spray, or bilge water. This inverter is designed for indoor use only. 
• Do not operate the inverter if it has received a sharp blow, been dropped, has cracks. 
• Do not disassemble the inverter. Internal capacitors remain charged after all power is disconnected. 
• Disconnect both AC and DC power from the inverter before attempting any maintenance, cleaning or working on any circuits 

connected to the inverter. See note below.

• Do not operate the inverter with damaged or substandard wiring. 
• Make sure that all wiring is in good condition and not undersized. 

Failure to follow these instructions will result in death or serious injury. 

FIRE AND BURN HAZARD 

• Do not cover or obstruct the air intake vent openings and / or install i n a zero-clearance compartment. 
• Do not use transformerless battery chargers in conjunction with the inverter due to avemeating.

Failure to follow these instructions will result in death or serious injury. 

EXPLOSION HAZARD 

• Do not work in the vicinity of lead-acid batteries. Batteries generate explosive gases during normal operation. 
• Do not install and /or operate in compartments containing flammable materials or in locations that require ignition-protected 

equipment.

Failure to follow these instructions will result in death or serious injury.

NOTES

1. Follow those instructions published by the battery manufacturer and the manufacturer of any equipment you intend to use in the 

vicinity of the battery. Review cautionary markings on these products and on the engine. 

2. The inverter contains components which tend to produce arcs or sparks. 
3. Avoiding locations include any space containing gasoline-powered machinery, fuel tanks, as well as joints, fittings, or other 

connections between components of the fuel system.

 

Caution

RISK OF DAMAGE TO THE INVERTER

• Never allow battery acid to drip on the inverter when reading gravity, or filling battery. 
• Never place the inverter unit directly above batteries, gases from a battery will corrode and damage the inverter. 
• Do not place a battery on top of the inverter. 

Failure to follow these instructions can damage the unit and/or damage other equipments.

2. INTRODUCTION

The new PDA series inverter are designed to give you quality power, ease of use, and reliability. These inverters have been upgraded 
from our previous PDA series, it is with new design case, improved technology and better workmanship. The PDA series digital 
inverter with digital LED, it indicates the voltage and power (V, P) constantly. 
Please take a few moments to read this chapter to familiarize you with the main performance features and protection features. 

2.1  QUALITY POWER & EASE OF USE 

The PDA series inverter have been superior features, rugged durability and ease of use: The unit is compact, light weight, and 
easy to install. Loads can be powered directly from inverter’s outlets. 

2.2  COMPREHENSIVE PROTECTION 

Our PDA series inverter are equipped with numerous protection features to guarantee safe and trouble-free operation:
• 

LOW BATTERY ALARM:

 Alerts you if the battery has been discharged to 10.5V or lower. 

• 

LOW BATTERY VOLTAGE SHUTDOWN:

 Shuts the inverter down automatically if the battery voltage drops below 9.5 volts. This 

feature protects the battery from being completely discharged. 

• 

HIGH BATTERY VOLTAGE SHUTDOWN:

 Shuts the inverter down automatically if the input voltage rises to 15.5 volts or higher. 

• 

OVER LOAD SHUTDOWN: 

Shuts the inverter down automatically if the loads connected to the inverter exceed the inverter’s 

operating limits.

• 

OVER TEMPERATURE SHUTDOWN: 

Shuts the inverter down automatically if its internal temperature rises to above an 

unacceptable level. 

• 

OUTPUT SHORT CIRCUIT SHUTDOWN:

 Shuts the inverter down automatically if a short circuit is detected in the circuitry 

connected to the inverter’s output.

• 

INPUT REVERSE POLARITY PROTECTION:

 The fuse shall blow if user connect the battery in wrong polarity.

Содержание PDA-D Series

Страница 1: ...PDA D series Convertidor DC AC Power inverter DC AC Manual de instrucciones p gina 2 User manual page 11...

Страница 2: ...quinaria que funcione con gasolina tanques de combustible as como juntas accesorios u otras conexiones entre los componentes del sistema de combustible Precauci n RIESGO DE DA OS AL INVERSOR Nunca per...

Страница 3: ...almente Fusible Manual de usuario Panel de salida alterna 7 3 4 1 5 1 2 6 1 2 3 4 5 6 7 Tomas de corriente alterna para alimentar cargas Interruptor de ENCENDIDO APAGADO ON OFF enciende y apaga el inv...

Страница 4: ...UBICACI N DEL INVERSOR El inversor solo debe instalarse en una ubicaci n que sea SECO El inversor debe instalarse en un lugar seco y no sujeto a la humedad especialmente lluvia rocio o salpicaduras d...

Страница 5: ...tro extremo del cable de tierra al chasis del veh culo a trav s de un punto de tierra en el veh culo si instala el inversor en un veh culo O conecte el otro extremo del cable a tierra a la tierra si i...

Страница 6: ...vocar la muerte o lesiones graves 10 1 ENCENDIDO Y APAGADO DEL INVERSOR El interruptor de ENCENDIDO APAGADO en el panel frontal del inversor es el interruptor de ENCENDIDO APAGADO principal que encien...

Страница 7: ...er as recargables L mparas de halogenuros met lico HlD Si no est seguro de alimentar cualquier dispositivo con el inversor p ngase en contacto con el fabricante del dispositivo 13 3 CONEXI N DE APARAT...

Страница 8: ...eligro de choque el ctrico No desmonte el inversor No contiene piezas reparables por el usuario El incumplimiento de estas instrucciones provocar la muerte o lesiones graves 17 2 TABLA 1 REFERENCIA DE...

Страница 9: ...na 1200W 1500W 2000W 2500W M xima potencia de salida de pico 2400W 3000W 4000W 5000W Rango de temperatura de funcionamiento 0 40 C 32 104 F Rango de voltaje de salida 220 240VAC Forma de la onda de sa...

Страница 10: ...necesarias para resolver el problema Este dispositivo est considerado como un bien o producto industrial que necesita de la intervenci n de un profesional conocedor de los detalles y par metros de in...

Страница 11: ...soline powered machinery fuel tanks as well as joints fittings or other connections between components of the fuel system Caution RISK OF DAMAGE TO THE INVERTER Never allow battery acid to drip on the...

Страница 12: ...mt cable included Optional part to be ordered separately Fuse User Manual Output AC panel 7 3 4 1 5 1 2 6 1 2 3 4 5 6 7 AC outlets are used to power loads ON OFF Switch turns the Inverter on and off...

Страница 13: ...exposed to metal fillings or any other form of contamination VENTILATED The ambient air temperature should be between 0 40 C 32 104 F for best performance SAFE Ventilation openings on the inverter mus...

Страница 14: ...of the ground cable to the vehicle chassis via a grounding point on the vehicle if you install the inverter in vehicle Or attach the other end of the ground cable to the earth If you install inverter...

Страница 15: ...ollow these instructions can result in death or serious injury 10 1 TURNING THE INVERTER ON AND OFF The ON OFF switch on the inverter s front panel is the main ON OFF switch that turns the control cir...

Страница 16: ...e about powering any device with the inverter contact the manufacturer of the device 13 3 CONNECTING APPLIANCES TO THE INVERTER Since regular amounts of AC current flows between the inverter and your...

Страница 17: ...not operate high power loads with the inverter when the television is on Danger ELECTRICAL SHOCK HAZARD Do not disassemble the Inverter It does not contain any user serviceable parts Failure to follow...

Страница 18: ...0 100 x 230 x 330 100 x 230 x 330 Weight g 2550 2900 3960 4220 Note Specifications are subject to change without prior notice Model PDA1200 PDA1500 PDA2000 PDA2500 Maximum output power continuous 1200...

Страница 19: ...ranty covers parts and labour necessary to solve the problem This device is considered as an industrial product that needs the intervention of a professional installer who knows details and installati...

Страница 20: ...Agente importador A48 139 786 UKAI S A Ribera de Elorrieta 7C 48015 Bilbao SPAIN Designed in EU Made in PRC fullwat com...

Отзывы: