Fullwat LIR18650-26 Скачать руководство пользователя страница 3

w w w . f u l l w a t . c o m

LIR18650-26

 

 

Rechargeable Lithium battery

  4. Specification

NO. Item 

Specifications

4.1 

Nominal capacity 

2600mAh 

Std. charge/discharge

 

Min. capacity 

2550mAh 

Std. charge/discharge

4.2 

Nominal voltage 

3.6V

4.3 

Charge current 

Standard Charge: 0.5C (1250mA)

   

 

Rapid charge: 1C (2500mA)

4.4 

Standard charging method 

1250mA (constant current) charge to 4.2V, then

   

 

CV (constant voltage 4.2V) charge till charge current

   

 

decline to ≤50mA

4.5 

Charging time 

Standard Charging

   

 

Approx 5 hours

   

 

Rapid charge

   

 

Approx 2 .5hours

4.6 

Max.charge current 

Constant Current 2500mA

   

 

Constant Voltage 4.2V 50mA cut-off

4.7 

Max.discharge current 

Constant current 10000mA end voltage3.0V

4.8 

Standard discharge current 

Constant current 500mA end voltage3.0V

4.9 

Discharge lower limit voltage 

3.0V

4.10 

Charge upper limit voltage 

4.20V

4.11 

Initial impedance 

≤60mΩ

4.12 

Weight  

Approx. 46g

4.13 

Operating temperature   

Charging 

0ºC ~45ºC

  

 

 

Discharging  -20ºC ~60ºC

 

 

-20ºC ~60ºC 

≤1 month 

Percentage of recoverable capacity no

4.14 

Storage temperature 

-20ºC ~45ºC 

≤3 month 

less than 70% of the initial capacities

  

 

-20ºC ~20ºC 

≤1 year

   

 

Constant current 1250 charge to 4.2V, then constant

   

 

voltage charge to current declines to 50mA, rest for

4.15 

Recoverable capacity 

10min. constant current 1250 discharge to 3.0V, rest for

   

 

10min. Repeat above steps 3 times, recording the

   

 

maximum capacity

4.16 

Storage humidity 

 

≤75% RH

4.17 

A ppearance 

 

Without scratch,distortion,contamination and leakage

   

 

 

Temperature: 23±5ºC

4.18 

Standard environmental condition 

Humidity: 45-75%RH

   

 

 

Atmospheric Pressure: 86-106 Kpa

Note

 - 

Above testing of safe characteristic must be with protective equipment.

Содержание LIR18650-26

Страница 1: ...w w w f u l l w a t c o m LIR18650 26 Rechargeable Lithium Battery ...

Страница 2: ...on describes the basic performance technical requirement testing method warning and caution of the Li Ion cylindrical rechargeable battery The specification only applies to FULLWAT 3 Initial dimension T 65 2 0 2 D 18 2 0 2 UNIT mm LIR18650 26 Rechargeable Lithium battery ...

Страница 3: ...rrent 500mA end voltage3 0V 4 9 Discharge lower limit voltage 3 0V 4 10 Charge upper limit voltage 4 20V 4 11 Initial impedance 60mΩ 4 12 Weight Approx 46g 4 13 Operating temperature Charging 0ºC 45ºC Discharging 20ºC 60ºC 20ºC 60ºC 1 month Percentage of recoverable capacity no 4 14 Storage temperature 20ºC 45ºC 3 month less than 70 of the initial capacities 20ºC 20ºC 1 year Constant current 1250 ...

Страница 4: ...5 1 2 This charge discharge cycle shall be repeated three times to measure the recovery capacity No Item Condition Specification 5 2 1 Initial AC Impedance Cell shall be measured at 1kHz after charge per 5 1 1 60mΩ 5 2 2 Initial Capacity Cells shall be charged per 5 1 1 and discharged Cini 2 500mAh Cmin per 5 1 2 within 1h after full charge 5 2 3 Cycle life Cells shall be charged and discharged pe...

Страница 5: ...ed at No explode No fire constant current of 3 times the max charge condition and constant voltage of 4 2V while tapering the charge current Charging is continued for 7 hours Per UL1642 5 5 2 External Short Cells are charged per 5 1 1 and the positive and No explode No fire Circuiting Test negative terminal is connected by a 100mΩ wire for 1 hour Per UL1642 5 5 3 Overdischarge Cells are discharged...

Страница 6: ...e discharge capacity significantly or cause overheating 7 Caution in use To ensure proper use of the battery please read the manual carefully before using it Handling Do not expose to dispose of the battery in fire Do not put the battery in a charger or equipment with wrong terminals connected Avoid shorting the battery Avoid excessive physical shock or vibration Do not disassemble or deform the b...

Страница 7: ...The battery long term has not used has the possibility to be able to be at because of its automatic flashover characteristic certain excessively discharges the condition for prevented excessively discharges the occurrence the battery should maintain the certain electric quantity Storing the Batteries The battery should store in the product specification book stipulation temperature range If has su...