Full Gauge TC-900RG2 slim Скачать руководство пользователя страница 2

WIRING DIAGRAM FOR

TC-900RG2 slim

IN1

IN2

GND

Power
supply

90~264Vac

Loads

supply

1

2

3

4

5

6

7

8

9

10

11

12

13

SET B

SET A

NOTE1: Connect the temperature sensors and the presets selector in the connectors
set A or B (according to the connection type of the supplied acessories) but not in
both sets at the same time.

NOTE2: If necessary, the sensor cables may be increased by the user until 200m using
PP 2 x 24AWG cable.

S1

S2

PS

Room sensor (black cable)

Evaporator sensor (gray cable)

Presets selector

S1

S2

PS

S1

S2

PS

5(3)A / 250Vac 1/8HP

10(3)A / 250Vac 1/4HP

6(8)A / 250Vac 1HP

FAN OUTPUT

DEFROST OUTPUT

COMPRESSOR OUTPUT

1

Wiring diagram of supressor directly

Load

Supressor

For direct drive
remind load current
specified

Wiring diagram of supressors in contactors

Supressor

A1

A2

A1 and A2 are the
contactor coil

IMPORTANT

As chapters of IEC 60364 norm:

Install

on power supply.

Sensor cables and computer signals can be together, however not at the same

place where power supply and load drive pass for.

Install suppressor of transient in paralell to loads to increase the usefull life of

relays. For more information contact our Application Eng. Department through

1:

2:

3:

protectors against over voltage

e-mail

or dial +55 51 34753308.

[email protected]

Led

1

Frontal

key

DIMENSIONS

KEY ACCES (FRONTAL PART) AND INDICATION

105mm

90mm

50mm

8mm

44mm

44mm

Отзывы: