Full Gauge TC-900RG2 slim Скачать руководство пользователя страница 1

The

allows adjustments of ±5.0°C in the room sensor (S1)

in relation to the standard calibration. For this just press the key for 15 seconds until
appearing the indication

. Use the same procedure to modify the value of

this function.

TC-900RG2 slim

The luminous pointer in the frontal signals the status of the controller:

The controller is in refrigeration mode, with the compressor

and fan ON. When the instrument is in refrigeration with the stopped indication led
blinks in a lesser frequency.

The controller is in refrigeration mode, with the compressor

and the fan OFF.

mode

a

Led blinking

Led turned off

Led turned on

The controller is in defrost

, with the compressor and

fan OFF and the resist nces ON.

Room sensor in short circuit or temperature above of P8

s

opened or

E

sensor damaged or temperature in the sensor below of

-30 ºC or above of

ºC. In this situation the duration of the thawing will be of 10

minutes.

Room ensor

temperature below of P7

vaporator

50

INDICATION DISPLACEMENT (OFFSET)

SIGNALLING

DIGITAL CONTROLLER FOR

REFRIGERATION AND DEFROST

Version 01

The

is a digital temperature

with outputs to

compressor, fan and defrost.

Beverage freezers

TC-900RG2 slim

controller

Application:

- Power supply:
- Maximum load:

- Sensors:

90~264Vac (50/60 Hz)

COMP - 1

FAN - 5(3)A / 250Vac 1/8HP - Fan output
DEFR - 10(3)A/ 250Vac 1/4HP - Defrost output

6(8)A / 250Vac 1HP - Compressor output

S1 (Room)
S2 (Evaporator)

0 to 50°C

10 to 90% RH (without condensation)

- Operation temperature:
- Humidity operation:

CONTROLS

R

Find manuals of all line on Web:

www.fullgauge.com

[email protected]

[email protected]

Phone/Fax: +55 51 34753308

MADE IN BRAZIL

DESCRIPTION

TECHNICAL SPECIFICATIONS

Put the selector keys

in the desired position and press the key for 10 seconds

until appear the indication

. Release key and wait until appears the value

programmed for this function, use the key again to modify this value. After adjusted
the new value for the function wait 4 seconds. The controller will record the new
parameter and will pass to the function

. Use the same procedure to modify

the value of this function. Repite this for the functions

and

that will be

the next to be showed in the display to be configured. After the alteration of the
parameters the display comes to the indication of temperature.

OPERATION PARAMETERS

Refrigeration time

Defrost time with the sensor of evaporator working

efrost time with the sensor of evaporator damaged

Control temperature (setpoint)

Differential of control (hysteresis)

inimum delay to restart the compressor

Low temperature or room sensor open

High temperature or room sensor in short circuit

Displacement of indication of room sensor (offset)

D

M

Parameters

0 0

1 1

12 hours

30 min.

10 min.

5.0 ºC

3.0 ºC

120 sec.

-20 ºC

45 ºC

0.0 ºC

10

30 min.

10 min.

2.0 ºC

3.0 ºC

120

-20 ºC

45 ºC

0.0 ºC

hours

sec.

0 1

1 0

6

30 min.

10 min.

-6.0 ºC

3.0 ºC

120

-20 ºC

45 ºC

0.0 ºC

hours

sec.

6

30 min.

10 min.

-1.0 ºC

3.0 °C

120

-20 ºC

45 °C

0.0 °C

hours

sec.

Item

P 1

P 2

P 3

P 4

P 5

P 6

P 7

P 8

P 9

SELECTOR KEYS POSITION

Programmable parameter, indication

at display

Programmable parameter, indication

at display

Programmable parameter, indication

at display

Programmable parameter, indication

at display

Programmable parameter, indication

in the display

Parameters v

Defrost on start

Refrigeration

isualization

When the controller is energized, it will appear the parameters of configuration in the
following order:

The controller will make defrost when energized if the temperature of the
sensor (S1) he will be below of 30 ºC and temperature of the sensor of the evaporator
(S2) below of 15 ºC.

The

REFRIGERATION TIME

DEFROST TIME

SETPOINT

DIFFERENTIAL

compressor turns on and turns off by temperature, according the value adjusted

in the P4 parameter (see table above) during the refrigeration time (P1). After
elapsed the time the controller will initiate a defrost cycle (if the temperature of the

sensor will be below of 30 ºC), turning off the compressor and the evaporator

fan. During the stage of refrigeration

remains turned on only while the

compressor will be functioning .

evaporator fan

room

room

PARAMETERS ALTERATION

Defrost

Delay

The defrost will be finished when the temperature in the evaporator (S2) reaches 15 ºC
or the temperature in the room (S1) reach 30 ºC . Otherwise, the defrost will be finished
after elapsed the maximum defrost time configured (P2 or P3). During the defrost the
last temperature measured in the refrigeration cycle will be frozen in the display. The
indication will be defrosted when this temperature be reached again or 15 minutes after
the end of the defrost.

When the instrument is energized or the temperature in the S1 sensor reaches the
setpoint (compressor turn off), the delay (P6) starts to be counted, preventing that the
compressor must be restarted in a period very short. Even than by temperature it wold
be necessary to turn on the compressor the delay (P6) is respected.
External selector
The external selector allows, with a combination of two keys, to define the functioning of
the controller with programmable presets.

FUNCTIONING DESCRIPTION

VISUAL ALARMS

KEY (ACCESS IN THE FRONT PANEL)

To change the refrigeration to defrost or vice-versa, just a simple touch on the key.To
visualize the temperature measured by the evaporator sensor (S2), keep pressed
the key for 5 seconds.

TC-900RG2 slim

TC-900RG2 slim

UL-Underwriters Laboratories