4. INDICATIONS AND KEYS
1
2
3
4
5
6
7
8
9
10
5.1 INSTALLATION - ELECTRICAL CONNECTIONS
6. OPERATIONS
6.1 Quick Access Menu Map
To access or navigate the quick access menu using the
;
(short press) key while the controller is
displaying the temperature. For every touch, the next function in the list is displayed. To confirm, use the
/
(short press) key.
5
4
3
2
9
8
7
6
1
10
6.2 QUICK ACCESS KEYS MAP
When the controller is on temperature display, the following keys serve as a shortcut for the following
functions:
1. DESCRIPTION
2. APPLICATION
3. TECHNICAL SPECIFICATIONS
For frozen products, it automates the defrost processes according to the need of installation (smart
defrost). The ambient temperature control has a normal setpoint and an economic setpoint, apart from
the fast freezing function and alarm functions indicating open door. Its 16A relay directly controls
compressors of up to 1HP and its defrost output has a current capacity of 10A.
It also features a digital filter, intended to simulate a mass increase in the ambient sensor (S1), thus
increasing its response time (thermal inertia) and avoiding unnecessary drives of the compressor. It also
includes a smart key, lock system and a control functions shutdown mode.
To drive inductive loads (motors and pumps) of up to 2HP, use the
e
TC-900 2HP.
• Cold Storage Rooms
• Display freezers
- Power supply:
TC-900 E POWER: 115 or 230Vac ±10% (50/60Hz)
TC-900 EL POWER: 12 or 24Vac/dc ±10%
- Control temperature:
-50°C to 105°C / -58°F to 221°F
- Operating temperature:
0 to 50°C / 32 to 122°F
- Load current (outputs): COMP:
12(8)A / 240Vac 1HP
DEFR:
10A / 240Vac 1/4HP
FANS:
5(3)A / 240Vac
- Operating humidity:
10 to 85 %RH (without condensation)
- Dimensions:
76 x 34 x 77 mm (WxHxD)
- Dimensions of the clipping for fixing of the instrument:
71 ± 0,5 x 29 ± 0,5 mm (see item 5)
evolution
TC-900
e
POWER
Ver
.04
Connection 115 Vac
TC-900
e
POWER
/
<
<
<
<
Pressed for 2 seconds: Setpoint adjustment.
Short press: Displays process status.
Short press: display of minimum and maximum measurement records.
Enters the functions selection.
6.3 BASIC OPERATIONS
6.3.1Setting the desired temperature
To access the setpoints setup menu press
/
for 2 seconds. The message
[SP,,]
will appear on the
display followed by the normal setpoint set value. Use the
>
or
<
to modify the value and confirm by
pressing
/
. Immediately, the message
[SP-e]
appears indicating the setting of the economic
setpoint. Again, use the
>
or
<
keys to modify the value and confirm by pressing
/
. Finally, the
[----]
indication signals the setup completion. The setpoints can also be adjusted individually in the
quick access menu.
TC-900
e
POWER
TC-900
e
POWER
<
Pressed for 2 seconds: inhibits audible alarm.
<
Pressed for 2 seconds: when displaying records, it cleans the history.
1
5 6 7 8
2 3 4
9
10 11 12 13 14 15 16 17
Sensor S1
D1/S3
D2
Sensor S2
230 Vac
CO
MP
DE
FR
FA
NS /
Panel (Front View)
Panel
(Side View)
Dimension of the clipping
for fixing of the
instrument in panel
71
mm
± 0,5
29
mm
± 0,5
FOR INSTALLATIONS WHERE A SEALING IS REQUIRED TO AVOID LIQUID CONTACT, THE CUT FOR THE CONTROLLER
MUST BE OF 70,5x29mm MAXIMUM. THE SIDE LOCKS MUST BE FIXED SO IT PRESSES THE RUBBER SEALING
AVOIDING INFILTRATION BETWEEN THE CUT AND THE CONTROLLER.
ATTENTION
DE
FR 2
;
Enters the quick access menu.
1
5 6 7 8
2 3 4
9
10 11 12 13 14 15 16 17
Sensor S1
D1/S3
D2
Sensor S2
CO
MP
DE
FR
Connection 230 Vac
115 Vac
FA
NS /
DE
FR 2
5. INSTALLATION - ASSEMBLING
and
Control functions
shutdown
Functions
lockdown
Serial
programming
Protection
level
IP 65
FRONT
Fast Freezing
FAST FREEZING (ON/OFF)
;
TC-900
e
POWER
;
ECONOMIC SETPOINT(ON/OFF)
TC-900
e
POWER
;
DEFROST (ON/OFF)
TC-900
e
POWER
;
FUNCTIONS LOCKDOWN
TC-900
e
POWER
;
CONTROL FUNCTIONS
(ON/OFF)
TC-900
e
POWER
NORMAL SETPOINT
;
TC-900
e
POWER
ECONOMIC SETPOINT
;
TC-900
e
POWER
MAX. AND MIN. TEMPERATURE
RECORD
;
TC-900
e
POWER
ERASE MAX. AND MIN.
VALUES
;
TC-900
e
POWER
EXIT FUNCTION
;
TC-900
e
POWER
FUNCTION SELECTION
;
TC-900
e
POWER
*The
sensor S1 (black)
must be in the ambient.
*The
sensor S2 (gray)
must
be placed in the evaporator
through metallic cramp.
Set key
Quick Access Menu Key
Compressor output indication LED
Fan/defrost indication LED 2
Defrost indication LED
Functions lock indication LED
Control functions shutdown indication LED
Temperature unit indication LED
Increase key
Decrease key
DIGITAL CONTROLLER FOR
REFRIGERATION AND DEFROST