11. GLOSSARY OF ACRONYMS
- °C:
Temperature in Celsius degrees.
- °F:
Temperature in Fahrenheit degrees.
-
Heat.:
Heating.
- LOC:
Blocked.
- OFF:
Turned off/disabled.
- ON:
Turned on, enabled.
- Refr:
Refrigeration.
- SET (as in "Setting")
(setting or configuration).
- Vac:
Electrical voltage (volts) of alternating current.
- Vdc:
Electrical voltage (volts) of direct current.
9. SIGNALS
Error in sensor: Sensor disconnected or damaged.
[Err1]
[LOC,][On,,]
[LOC,][OFF,]
[OFF,]
[ClO,]
[EClO]
[ALrM]
[eCAL]
[pppp]
Functions lock.
Unlocking of functions.
Control functions off.
Contact Full Gauge Controls.
Reconfigure the values of the functions.
F09- Time for manual activation of the event output:
Time for which the event output remains on when manually activated. After this time has elapsed the
event output returns to the automatic operation. This function can be switched off by setting it at the
minimum value 0
[No,,]
.
F10 - Preferred measurement view:
It allows choosing which measurement will be displayed:
[Temp]
- Temperature (if sensor is enabled).
[Hour]
- Hour
[All,]
- Switches between temperatures (if sensor is enabled) and time.
F11 - Recirculation - Scan time (if F05 = 1- heating):
Time during which the controller keeps the water circulation activated to equalize the water temperature
in the keg.
F12 - Interval between scans (if F05 = 1- heating):
It is the interval between the last and the next temperature scan.
NOTE:
If the temperature to switch on the thermostat is reached the scan cycle is restarted.
F13 - Maximum time the thermostat output remains on without reaching the setpoint (if F05 = 1-
heating):
It is the maximum time the thermostat output will remain on without reaching the setpoint during the
heating process. When this time is exceeded the visual alarm
[alrm]
is activated and the thermostat
output remains off according to the time defined in F13. Functions F12 and F13 serves as protections for
the gas-fired heater so that in case of fault (flame out for instance), the water circulation is interrupted
and the heater is switched off to protect it.
This function can be switched off by setting it at the minimum value 0
[no,,]
.
F14 - Thermostat output off time in state of alarm for not reaching the setpoint (if F05 = 1-
heating):
It allows adjusting the time for which the controller will keep the thermostat output off while in state of
alarm for not reaching the setpoint. If the setpoint is reached during this time the alarm is switched off. If
the setpoint is not reached after this time has elapsed, new checks are performed during the time
defined in F12.
F15 - Digital input operating mode:
Allows the output associated with the event calendar to be associated outside of the schedule of events,
respecting the functions options and F07- Toggle thermostat to the event schedule and F09- Time of
manual activation of the event output.
[Off,]
Off
[,,,1]
Activate / deactivate manual override (NO button)
[,,,2]
Activate / deactivate manual activation (NF button)
F16 - Digital filter intensity applied to the sensor:
This filter has the purpose of simulating an increase in thermal mass at the sensor thereby increasing its
response time (thermal inertia). The higher the value set in this function, the more time the sensor takes
to respond. This function can be switched off by setting it at the minimum value 0
[no,,]
.
F17 - Function lock mode:
It allows and configures the function lock.
[,,,0]
Do not allow the function lock.
[,,,1]
It allows a partial lock where the control functions will be locked but the adjustment of the
setpoint, date views, and maximum and minimum record views are allowed.
[,,,2]
It allows the full lock, enabling only the date views and maximum and minimum record views.
F18 - Time for functions lock:
Allows lockdown of control functions (see item 8.3.2).
[,,15]
-
[,,60]
- Defines the time in seconds for the controller to activate.
F19 - Control functions shutdown:
Allows the turning off the control functions (see item 8.3.3).
[,,,0]
Disables the control functions shutdown.
[,,,1]
Enables activation/deactivation of the control functions only if the functions are unlocked.
[,,,2]
Enables activation/deactivation of the control functions even if the functions are locked.
[,,,3]
It enables the activation/deactivation of the control functions only if the functions are unlocked,
switching off the display.
[,,,4]
Enables activation/deactivation of the control functions even if the functions are locked,
switching off the display.
NOTE:
In options 3 and 4 the display is switched off if no keys are pressed and switched on when any
key is pressed, remaining on for five seconds.
F20 - Address of the instrument in the RS-485 network:
Equipment's network address for communicating with Sitrad® software.
Note:
One network must not have different equipment with the same address.
Adjustment or visualization of the date and time.
Invalid date and/or time (adjust the clock).
12. OPTIONAL ITEMS - Sold Separately
Ecase protective cover
It is recommended for the Evolution line, keeps water from entering the back part of the instrument. It
also protects the product when the installation site is washed.
ECASE PROTECTIVE COVER
Extended frame
It allows the installation of Evolution line controllers with sizes 76 x 34 x 77 mm in various situations,
since it does not require precision in the notch of the instrument fitting panel. The frame integrates two
switches of 10 Amperes that may be used to actuate interior light, air curtain, fan, and others.
CONTROLLER
EXTENDED
FRAME
SWITCHES
Alarm for failure to reach the setpoint.
10.
INTEGRATING CONTROLLERS, RS-485 SERIAL INTERFACE
AND COMPUTER
A
B
MT-530
super
A
B
MT-530
super
A
A
B
B
A B
A
B
A
A
B
B
A B
A
A
B
B
A B
A
A
B
B
A B
*Connecting Block for Serial Communication
Used to connect more than one instrument to the Interface. The wire's connections must
be made in agreement with the following rules: terminal
A
of the instrument connects to
the terminal
A
of the connecting block, that must be connected with the terminal
A
of the
Interface. Repeat the action for terminals
B
and
, being
the cable shield.
the terminal
of connecting block must be connected to the respective terminals
of
each instrument.
*Sold Separately
CONV. 32
or
CONV. 256
Keep Sitrad updated in website:
http://www.sitrad.com
®
- version 2 or higher
EasyProg
It is an accessory that has as its main function to store the parameters of the controllers. At any time, you
can load new parameters of a controller and download them on a production line (of the same
controller), for example. It has three types of connections to load or unload the parameters:
- Serial RS-485:
It connects via RS-485 network to the controller (only
for controllers that have RS-485).
- USB:
it can be connected to the computer via the USB port, using
Sitrad's Recipe Editor.
- Serial TTL:
The controller can be connected directly to
EasyProg
by the TTL Serial connection.
EASYPROG
IMPORTANT
TO PERFORM THE COMMUNICATION
WITH EASYPROG THIS EQUIPMENT MUST
NOT BE COMMUNICATING WITH SITRAD
SOFTWARE.
Watch Sitrad installation video in:
http://www.fullgauge.com/
videos/sitrad