ADJUSTMENT OF THE DESIRED TEMPERATURE (SETPOINT) OF
THE OVEN:
Defines the working temperature of the oven. This parameter can be adjusted between the
values defined in F02- Minimum value allowed to configure the oven temperature setpoint and
F03 - Maximum value allowed to configure the oven temperature setpoint.
TIMER ADJUSTMENT:
Defines the cooking time. When the time expires, the audible alarm output is switched on
intermittently until any key on the controller’ s front panel is pressed. The timer can be adjusted
between 00:01 and 99:59. The time scale is adjusted in parameter F14 - Time base of the timer.
7.2 Steam activation
The steam operating mode is defined in parameter F18 - Steam Operating Mode. Steam activation depends on
parameters F20 - Time interval between steam activations and F21 - Minimum temperature to activate the steam,
available in the advanced configuration menu. These conditions must be met for the injection of steam in the oven
to occur.
7.2.1 Steam activation times
Press the
%
key and hold for 4 seconds to adjust. Use the
<
and
>
keys to adjust the value of the parameter.
To confirm, perform a quick touch on the
%
key.
STEAM OUTPUT ON TIME:
This parameter can be adjusted between 1 and 30 seconds, and the factory default is 5
seconds.
STEAM OUTPUT OFF TIME:
This parameter can be adjusted between 1 and 600 minutes, and the factory default is 3
minutes.
NOTE:
This parameter is available for adjustment when the steam control mode selected is
cyclic
[F18]
=
[CYC,]
.
7.3 Presets
A preset includes the configuration of oven temperature, timer, and steam operating mode. The controller has 20
presets that can be edited by the user, and the presets can be selected in a simplified way.
7.3.1 Preset selection
7.3.2 Preset configuration
To access the preset configuration menu, keep the
key pressed down for 4 seconds. Then use
<
or
>
to
ddddd
select the parameter to be adjusted, use the
key to access the parameter, and then use
<
or
>
to adjust
dddd
the value of the parameter. To leave the preset menu and return to the normal operating mode (temperature and
time indication), keep the
key pressed down (press and hold) until
[----]
is displayed.
ddddd
To select a preset in the controller, perform a quick touch on the
key and then use
<
or
ddddd
>
to select the desired preset.
- QUICK TOUCH
: cancel preset selection;
- PRESS AND HOLD
: confirm preset selection;
The
*
icon indicates that the preset mode is active.
REC
REC
REC
REC
REC
REC
FAN CONTROL MODE:
Selects the control mode for the fan:
[ON,]
= On, the fan is controlled via output FAN 1.
[ALT]
= Alternated, reverses the rotation direction of the fan via outputs FAN 1 and FAN 2, in
i
accordance with parameters F23 and F24.
Turbine shutdown option
: If option
I09 - Enable the stand-by oven function
is set to ‘’YES’’, the turbine output
can be temporarily disabled in the following ways:
-
Manual shutdown
: Press the
<
key and hold for approx. 4 seconds.
-
Automatic shutdown
: Via function
F26 - Automatic turbine shutdown after completion of the cooking
time
the turbine can be temporarily disabled after completion of the cooking process timer;
The turbine output will remain deactivated respecting the time set in function F25 - Maximum turbine off time after
deactivation and while the timer is not activated, otherwise the turbine will also be activated again. While it is off, a
message will appear on the lower display informing that the turbine is off. You can activate the turbine output
again at any time by pressing
<
again for 4 seconds.
However, turning off the turbine is only allowed while the timer is deactivated, otherwise an error message will be
displayed indicating that the turbine cannot be switched off.
Selects the number of the preset to be
configured. There are 20 presets that can
be customized by the user.
Select the preset to be
configured
1
20
-
1
7.3.2.1 Preset configuration table
8.2 Parameters table
8.1 Changing the controller parameters
MIN
MIN
MAX
MAX
UNIT
UNIT
DEFA
DEFAU
DESCRIPTION
DESCRIPTION
FUN
FUN
FUNCTION
FUNCTION
[rCnF]
Adjustment of the timer for the preset
selected by parameter
[rCnF]
.
Defines the steam operating mode for the
selected preset
[rCnF]
:
[OFF,]
Off: does not inject steam.
[MAN,]
M
anual:
injects steam when the
%
key is pressed.
[AUT,]
Automatic: automatically injects
steam after the timer is activated. The
steam is activated after the time set in F19
has elapsed.
[CYC,]
Cyclic: injects steam in cycles
using the times configured in
[UAon]
and
[UAof]
.
OFF CYC
-
MAN
Oven temperature setpoint
for the selected preset
Adjustment of the oven temperature
setpoint for the preset selected by
parameter
[rCnF]
.
ºC
(ºF)
180
(356)
Timer adjustment for the
selected preset
[rtm,]
00:01 99:59 F14 18:00
Steam operating mode for
the selected preset
[rUa,]
[,rsP]
(F02) (F03)
7.4 Functions lock
To enable / disable the function lock, press
<
and
>
and hold for the time configured in
parameter.
F28 - Time for function lock.
When this configuration is active, the parameters cannot be changed, but they can be viewed.
When the lock is active, the parameters available for adjustment are defined in parameter
F27
- Functions Lock
.
Icon
&
indicates the status of the lock. Icon lit indicates the functions lock is active.
To enable the Default (standard) operating mode of the oven, the controller must be powered
up with the
$
and
%
keys pressed until the message appears on the display. This mode is
available when the type of oven selected is GAS. For more details about this operating mode
check item 6.4 Default Mode (standard).
7.5 Enable Default (standard) operating mode
IN THIS OPERATING MODE THE FLAME SENSOR IS IGNORED AND THE CONTROLLER WILL
NOT DETECT THE PRESENCE / LACK OF FLAME, BEING ESSENTIAL FOR THE OPERATOR TO
PAY SPECIAL ATTENTION TO THE CONTROL OF THE OVEN IN ORDER TO PREVENT GAS
ACCIDENTS
7.6 STAND-BY Function
When function
I09 - Enable stand-by oven functionality
is set to
YES
, the controller can be put on standby at
any time by the user. This functionality allows for the control to be kept disable (all outputs off). To put the
controller on stand-by mode, press
>
for approx. 4 seconds, until the message
[OFF]
is displayed.
While the controller is on stand-by, the display will flash the
>
key icon to indicate for the key to be pressed
againd for 4 seconds to reactivate the oven control.
Use the
<
or
>
keys to select the desired function. The value can be edited with a quick touch on the
dddd
key. Use the
<
or
>
keys to change the value and press the key with a quick touch when ready to save the
configured value and return to the functions menu. To leave the configuration menu and return to the normal
operating mode (temperature and time indication), press
(press and hold) until
[----]
is displayed.
dddd
Access the advanced configuration menu by pressing the
key for 4 seconds until
dddd
[FuNc]
is displayed. When
[CoD]
is displayed press the key again (quick touch). Use the
<
or
>
keys to enter the access code 123 and press
(quick touch) again when ready.
dddd
8. OPERATIONS - ADVANCED LEVEL
SET
SET
SET
SET
Access Code (123)
Required when you want to change the advanced
configuration parameters.
[CoD]
0
9999
-
0
Temperature sensor indication
offset
Allows compensating deviations in the
sensor temperature reading.
[F01]
-20
(-4)
20
(36)
°C
(°F)
0
(0)
These parameters serve as the lower and
upper thresholds for the adjustment of
parameter ‘’SP’’ - oven temperature
setpoint. They are used to block
temperature adjustments and to avoid an
improper configuration for the operation of
the oven.
Minimum value allowed to
c o n f i g u r e t h e o v e n
temperature setpoint
Maximum value allowed to
c o n f i g u r e t h e o v e n
temperature setpoint
[F02]
[F03]
-10
(14)
F03
°C
(°F)
0
(32)
F02
500
(932)
°C
(°F)
230
(446)
Oven temperature differential
(Hysteresis)
The temperature difference to switch on
the heating output. This function allows
defining a temperature interval within
which the heating output will remain off.
[F04]
1
(1)
20
(36)
ºC
(ºF)
3
(5)
Delay to switch off the
temperature control
when the door of the
oven is opened
Defines the delay to switch off the
temperature control when the oven door is
opened to allow furnishing the oven without
switching off the control. To disable this
function, change the adjustment to the
minimum until
[no,]
is displayed. In this
case, the temperature control is switched
off as soon as the door is opened.
[F05]
no(0) 180 sec.
Number of attempts to light the
flame (GAS-FIRED OVEN)
Defines the maximum number of attempts
the controller will try to ignite the flame.
After using up all attempts, the controller
will signal error
[ER5]
-Out of Gas.
Note:
This parameter is used when the
type of oven selected is GAS.
[f06]
1
5
-
Ignition output on time (GAS-
FIRED OVEN)
Defines the time the ignition output will stay
switched on to try to ignite the flame.
Note:
This parameter is used when the
type of oven selected is GAS.
[f07]
1
15
sec.
90
3
3
Delay to activation of the
i g n i t i o n o u t p u t a f t e r
controller start up (GAS-
FIRED OVEN)
Defines the delay to activate the ignition
output after the gas output is activated in
the first attempt to ignite the flame. This
time is used so that the gas from the
cylinder reaches the burner and then the
ignition is activated.
Note:
This parameter is used when the
type of oven selected is GAS.
[F09]
no
(0)
15
sec. no(0)
Interval between activations
of the ignition output (GAS-
FIRED OVEN)
Defines the interval between attempts to
activate the flame.
Note:
This parameter is used when the
type of oven selected is GAS
[f08]
1
15
sec.
3
Delay of the temperature
control after controller start
up (GAS-FIRED OVEN)
When the controller is powered up, the fan
is actived first and then the flame ignition
process commences after the time
adjusted in this parameter has elapsed.
Note:
This parameter is used when the
type of oven selected is GAS.
[F10]
no
(0)
30
sec.
1
The controller has easy access to resources that are relevant to the user of the oven.
7.1 Adjustment of oven temperature and timer
To adjust oven temperature and timer, perform a quick touch on the
SET
key. Use the
<
and
>
keys to adjust the
value of the parameter. To advance and/or terminate the adjustement, perform another quick touch on the
SET
key.
7. OPERATIONS - BASIC LEVEL