In case of a disconnected sensor or temperature out specified range a            will appear on the display.
Process stages:

      Initial delay (delay to start the control)

Fan-delay (delay to fan return)
Refrigeration
Pre-defrost
Defrost
Draining 

Hour meter display:                    Number of hours worked by the compressor

NOTE: 

If the number of hours of the compressor exceeds 999, the number will be shown in two steps: 

Thousands first and then hundreds, tens and units.

6.2 - Manual defrost (instant)

To perform a manual defrost regardless of programming, keep the key         pressed for 4 seconds until 
the indication            is shown. Release the key and            will appear.
If the instrument is in the defrost cycle and an interruption is required, proceed as per the instructions 
above until the indication             is shown. Release the key and            will appear.

6.3 - Minimum and maximum temperature register 

By pressing        , short touch, the           sign will appear and the maximum and minimum temperatures 
of the sensor S1(ambient temperature) will appear. Soon           will appear showing the minimum and 
maximum temperatures of the sensor S2 (evaporator). Next will appear the minimum and maximum 
voltages, preceded by the              sign .

Note:

  To  reset  settings,  hold  the            key  through  all  the  minimum  and  maximum  temperature 

visualization until             appear.

6.4 - Visualizing the current weekday and time

Press quickly the          key. It will appear:

DAY OF THE MONTH        MONTH       YEAR        HOURS        MINUTES        SECONDS      DAY   

OF THE WEEK

 

6.5 - Viewing the supply voltage

By pressing the         and         keys for 5 seconds, it will appear the supply voltage of the instrument, 
preceded by the             message.

SET

SET

- Indication of high voltage
- Indication of low voltage
- Reference to the memory of the datalogger
- Indication to clear the memory of the datalogger
- Indicates that the instrument is resetting the values

Frontal LEDs 

COMP - refrig / compressor  (16A)
FANS -  evaporator fans  (5A)
DEFR - defrost  (1A)
ALRM - alarm  (5A)
ECO - economic setpoint active (saving energy)

CO

MP

- The sensor S1 (black) must be in the ambient.
- The  sensor  S2  (gray)  must  be  placed  in  the 
evaporator through metallic cramp.
- The sensor cable length can be increased by the 
user  until  200  meters  using  the  PP  2  x  24 AWG 
cable.

 

Power 
supply

0 +12Vdc   +24Vdc

AL

RM

DE

FR

FA

NS

Loads

supply

CO

MU

M

S

en

so

r S

1

(b

la

ck

)

S

en

so

r S

2

(g

ra

y)

4

5

6

7

8

9 10 11 12

3

2

1

2

1

4 - 5
4 - 6

12Vdc
24Vdc

9 - WIRING DIAGRAM

Compressor

supply

Serial communication

RS-485

Selection for monitoring 

the voltage

Digital

input 1

Digital

input 2

12V

B A

24V

COMP: 12(8)A / 240 Vac 1HP

FANS: 5(3)A / 240Vac 1/8HP

DEFR: 1(3)A / 240Vac

ALARM: 5(3)A / 240Vac 1/8HP

FAN-DELAY

REFRIGERATION

DEFROST

DRAINING

Indication released

F09

to

F10

F21  F51

to      to

F30  F56

F31

F11

to

F20

Indication locked if enabled in

 (

 F30)

PRE-DEFROST

F24

6.7 -  Manual datalogger activation

Press        and         simultaneously for 10 seconds to activate or deactivate the operation of the internal 
voltage recorder (data-logger). The message             will be showned followed by the message
when the data-logger is activated and            when it is deactivated.
Note:   The status of the datalogger will only change alternate between            and             if the function 
F46 is set to 2 (manual datalogger operation).

6.8 - Hour-meter reset

When the number of hours with the compressor on reaches the value set in F63, the display will show a
           warning, indicating that maintenance should be done. To reset this counter (It can be done only 
after the warning occurs), press           for 10 seconds.

6.9 - Turn off the control functions

Pressing         for 5 seconds, the controller will go to a state where only temperatures and voltages are 
read, where no control are performed and where all outputs kept off. Communication with SITRAD 
software and the Datalogger will still work. To make the device fully operational again,  press          again 
for 5 seconds.

SET

TC-960Ri LOG

RS-485

®

A

A

B

B

A B

A

A

B

B

A B

RS-485

7 - UNIT SELECTION (°C / °F)

To define the unit that the system will use to operate, enter into the functions menu                   using the 
access code “231” and confirm it by hitting key         . Press the         key. It will appear            , press again
         to enter the function. Use the         or         keys 

to choose between             or             and confirm 

with the           key.  After selecting the unit the           message will appear, and the instrument will return 
to the function           . Whenever the unit is altered, the parameters should be reconfigured, since they 
assume ”standard” values.

8 - INDICATORS AND ALARMS

- Low temperature
- High temperature
- Voltage out of range
- Open door
- Pressostat
- Datalogger memory full
- Economic setpoint active 
- Outputs manually deactivated
- Compressor maintenance
- Compressor ON without reaching the setpoint (F20)
- Ambient sensor S1 disconnected or temperature out of range
- Evaporator sensor S2 disconnected or temperature out of range
- Temperature Indication
- Indication that defrost will be performed
- Indication of activation
- Indication of deactivation

6.6 - Clearing datalogger memory:

Press the        and         keys for 4 seconds to display                    . The display shows           . If you 
don't want to clear the memory press        . To clear the memory press       until          is displayed and 
press           to confirm and exit the function.

SET

SET

SET

SET

SET

SET

Over the specifield current 

use a contactor.

Brown - A 

Red - B

Serial

communication

RS-485

External

mesh

       terminal 

grounded

Serial interface 

 RS-485

Full Gauge

RS-485 Serial Interface

®

Device  used  to  establish  the 
connection Full Gauge Controls’ 
instruments with the Sitrad

.

Distribution Box 

Used to connect more than one instrument to the Interface. The 
wire's connections must be made in agreement with the following 
rules: terminal 

A

 of the instrument connects to the terminal 

A

 of 

the distribution box, that must be connected with the terminal 

A

 of 

the Interface. Repeat the action for terminals 

B

 and 

      

, being

the cable shield.  
the terminal          of distribution box must be connected to the 
respective terminals       of each instrument.

IMPORTANT

As chapters of IEC 60 364 norms:

1:

 Install protectors against over voltage on power supply

2:

 Sensor cables and computer signals can be together, however not at the same place where power supply 

And load drive pass for.

3: 

Install suppresor of transient (RC filter) in parallel to loads, as for to increase the useful life of the relays.

10 - INTEGRATING CONTROLLERS, RS-485 SERIAL INTERFACE 

AND COMPUTER

ENVIRONMENTAL INFORMATION

Package:

The  packages  material  are  100%  recyclable.  Just  dispose  it  through  specialized 
recyclers.

Products:

The  electro  components  of  Full  Gauge  controllers  can  be  recycled  or  reused  if  it  is 
disassembled for specialized companies.

Disposal:

Do not burn or throw in domestic garbage the controllers which have reached the end-of-
life.  Observe  the  respectively  law  in  your  region  concerning  the  environmental 
responsible manner of dispose its devices. In case of any doubts, contact Full Gauge 
controls for assistance.

Содержание TC-960Ri LOG

Страница 1: ...g fan delay Minimum time of compressor turned on Minimum time of compressor turned off Compressor status with inoperative ambient temperature sensor S1 Fan on with compressor off refrigeration Fan stopped for high temperature in the evaporator S2 Fan return hysteresis after stopping due to high evaporator temperature Maximum refrigeration time for security if F22 1 Evaporator temperature to start ...

Страница 2: ... that the compressor will keep turned off it means the time period between the last stopped and the next started It serves to alliviate the pressure and to increase the useful life of the compressor F13 Compressorstatuswithdetachedambientsensor S1 If the ambient sensor S1 is detached or out specified range the compressor assumes the configured statusinthisfunction Exemple For counters that storage...

Страница 3: ...emoryisfulltheinstrumentandSitradwillsignalfullmemory F51 Numberofdefrostsperday MondaytoFriday The defrost cycles are evenly distributed in accordance with the number of defrosts set per day always considering the preferred time The value can be adjusted to 1 2 3 4 6 8 or 12 This function works to scheduletheoperationfromMondaytoFriday Indicateswhetherthechangeinanyoutputwillforcetherecordingofda...

Страница 4: ...hat maintenance should be done To reset this counter It can be done only afterthewarningoccurs press for10seconds 6 9 Turn off the control functions Pressing for 5 seconds the controller will go to a state where only temperatures and voltages are read where no control are performed and where all outputs kept off Communication with SITRAD softwareandtheDataloggerwillstillwork Tomakethedevicefullyop...

Страница 5: ...or PROTECTIVE VINYL This adhesive vinyl included inside the packing protects the instruments against water drippings as in commercial refrigerators for example Do the application after finishingtheelectricalconnections Remove the protective paper and apply the vinyl on the entire superior part of the device folding the flaps as indicated by thearrows 72 mm Dimension of the clipping for setting of ...

Отзывы: