5.9 - Alarm inhibition

To inhibit the alarm output press the key

. The messages

will appear.

After the inhibition, the alarm output returns to be enabled when the instrument leaves the alarm status.

SET

A

A

B

B

A B

RS-485

®

A

A

B

B

A B

A

A

B

B

A B

RS-485

SERIAL

Brown - A

Red - B

TC-940Riplus

SERIAL

Brown - A

Red - B

TC-940Riplus

5.8 - Registers of minimum and maximum temperatures

Press

. Will appear

and minimum and maximum temperatures of black sensor ( ambient). After

appear

and minimum and maximum temperatures of gray sensor (evaporator).

To reset the registers, keep pressed

during visualization of minimum and maximum temperatures

until appear

.

Note:

Power

supply

6. WIRING DIAGRAM

COMP

DEFR

FANS

COMUM

1

2

4

5

6

7

8

9

10 11 12

3

1

2

4

5

6

7

8

9

10 11 12

3

ALRM

Digital input

B

A

IN

GND

Sensor

gray

cable

(evaporator)

2

Sensor

black

cable

(ambient)

1

Loads

supply

Over the specifield current

use a contactor.

To the terminal

of

the distribution box

Integrating Controllers, RS-485 Serial Interface and Computer

Serial interface

RS-485

Full Gauge

External

mesh

terminal

grounded

RS-485 Serial Interface

®

Device used to establish the
connection Full Gauge Controls’
instruments with the Sitrad

.

Distribution Box
Used to connect more than one instrument to the Interface. The
wire's connections must be made in agreement with the following
rules: terminal

of the instrument connects to the terminal

of

the distribution box, that must be connected with the terminal of
the Interface. Repeat the action for terminals and

, being

the cable shield.

A

A

A

B

the terminal

of distribution box must be connected to the

respective terminals

of each instrument.

Serial

communication

RS-485

Serial

communication

RS-485

IMPORTANT

1:
2:

3:

According to the chapters of norm IEC 60364:

Install

on the power supply

Sensor cables and signal cables of the computer may be joined, but not in the same electric conduit

through which the electric input and the activation of the loads run

Install transient suppresors (RC filters) parallel to the loads as to increase the product life of the

relays.

protector against overvoltage

For more information, please contact our Technical Support by e-mail:

or by

phone +55 51 3475.3308

[email protected]

Schematic for the connection of supresors
to contactors

Suppresor

A1

A2

A1 and A2 are the
contactor coil terminals.

Schematic for the connection of supresors to
direct activation loads

Load

Suppresor

For direct activation the maximum
specified current should be taken
into consideration.

Note: The sensor cable lenght can be increased by the user until 200 meters using 2 x 24AWG cable.

PROTECTIVE

:

VINYL

This adhesive vinyl (included inside the packing) protects the instruments against
water drippings, as in commercial refrigerators, for example. Do the application after
finishing the electrical connections.

Remove the protective paper
and apply the vinyl on the entire
superior part of the device,
folding the flaps as indicated by
the arrows.

72 mm

Dimension of the clipping

for setting of the instrument

in panel

29

mm

12Vdc

5.10 - Inhibition of the alarm sound

To inhibit the audible alarm press the key

for two seconds. After the inhibition, the audible alarm

returns to be enabled when the instrument leaves the alarm status.

Serial

communication

RS-485