Start of the process time.

End of the process time.

[Tmr1] 

[Tmr2] 

[Tmr3] 

[Tmr4]

 Remaining time of process.

Control functions off.

Lock functions.

[Err,]

[Ctrl][On,,]

[Ctrl][OFF,]

[LOC,][On,,]

[LOC,][OFF,]

7. SIGNALS

Sensor damaged, disconnected or out of temperature range.

Control functions on.

[StA2]

[StA3]

[StA4]

[End1]

[End2]

[End3]

[End4]

[StA1]

Unlocking functions.

[vap,]

[nvap]

[prep]

Steam.

Invalid conditions for activating the steam.

Pre-process in progress.

8. OPTIONAL ITEMS - Sold Separately

8.1

 

EasyProg - 

version 2 or higher

It is an accessory that has as its main function to store the parameters of the controllers. At any time, you 
can load new parameters of a controller and unload them on a production line (of the same controller), for 
example. It has three types of connections to load or unload the parameters:

8.2 Ecase

It is recommended for the Evolution line, keeps water from entering the back part of the instrument. It also 
protects the product when the installation site is washed.

8.3 Extension Frame

The Full Gauge Controls extension frame allows the installation of Evolution / Ri line with measures 
76x34x77  mm  (dimensions  of  the  clipping  for  fixing  in  the  extension  frame  is  71x29mm)  in  varied 
situations, since it eliminates precision cut to embed the instrument. Allows customization via a sticker with 
the brand and the company contact, and accompany two 10A (250 Vac) switches that can trigger internal 
light, air curtain, on / off system or fan.

- Serial RS-485:

 It connects via RS-485 network to the controller (only 

for controllers that have RS-485). 

- USB:

 it can be connected to the computer via the USB port, using 

Sitrad's Recipe Editor.

-  Serial  TTL: 

The  controller  can  be  connected  directly  to 

EasyProg 

by the TTL Serial connection.

EASYPROG

8.4 Surge Protective Device (SPD)

Wiring diagram for instalation of SPD in magnectic 

contactor

SPD

A1

A2

A1 and A2 are the terminals
of the contactor coil.

Wiring diagram for instalation of SPD in line with 

loads

LOAD

For direct drive take in to 
consideration the specified 
maximum current.

RC FILTER

SPD

ENVIRONMENTAL INFORMATION 

Packaging:

The materials used in the packaging of Full Gauge products are 100% recyclable. Try to 
perform disposal through specialized recyclers.

Product:

The  components  used  in  Full  Gauge  controllers  can  be  recycled  and  reused  if 
disassembled by specialized companies.

Disposal:

Do not incinerate or dispose the controllers that have reached the end of their service as 
household garbage. Observe the laws in your area regarding disposal of electronic 
waste. If in doubt, please contact Full Gauge Controls.

Rev. 03

Products manufactured by Full Gauge Controls, as of May 2005, have a two (02) year 

warranty, as of the date of the consigned sale, as stated on the invoice. They are guaranteed 
against manufacturing defects that make them unsuitable or inadequate for their intended 
use.

EXCEPTIONS TO WARRANTY

The Warranty does not cover expenses incurred for freight and/or insurance when sending 

products  with  signs  of  defect  or  faulty  functioning  to  an  authorized  provider  of  technical 
support services. The following events are not covered either: natural wear and tear of parts; 
external damage caused by falls or inadequate packaging of products.

LOSS OF WARRANTY

Products will automatically lose its warranty in the following cases:
- The instructions for assembly and use found in the technical description and installation 

procedures in Standard IEC60364 are not obeyed;

-  The  product  is  submitted  to  conditions  beyond  the  limits  specified  in  its  technical 

description;

- The product is violated or repaired by any person not a member of the technical team of 

Full Gauge Controls;

- Damage has been caused by a fall, blow and/or impact, infiltration of water, overload 

and/or atmospheric discharge.

USE OF WARRANTY

To make use of the warranty, customers must send the properly packaged product to Full 

Gauge Controls together with the invoice or receipt for the corresponding purchase. As much 
information as possible in relation to the issue detected must be sent to facilitate analysis, 
testing and execution of the service.

These  procedures  and  any  maintenance  of  the  product  may  only  be  provided  by  Full 

Gauge Controls Technical Support services in the company's headquarters at Rua Júlio de 
Castilhos, 250 - CEP 92120-030 - Canoas - Rio Grande do Sul – Brasil

W

ARRANTY

 - FULL

 GAUGE CONTROLS

Copyright 2015

All rights reserved.

Содержание MT-622E

Страница 1: ...ories If you have any questions please contact technical support AUTHORIZED SERVICE The installation or maintenance of the product must be performed by qualified professionals only BEFORE INSTALLING THE CONTROLLER WE RECOMMEND READING THROUGH THE ENTIRE INSTRUCTION MANUAL IN ORDER TO AVOID POSSIBLE DAMAGE TO THE PRODUCT PRECAUTIONS WHEN INSTALLING THE PRODUCT Before performing any procedure on thi...

Страница 2: ...mperatureandremainingtimeofeachprocess Temp Temperature Tmr1 Remainingtimeofprocess1 Tmr2 Remainingtimeofprocess2 Tmr3 Remainingtimeofprocess3 Tmr4 Remainingtimeofprocess4 Note In operating modes 1 and 4 of the F49 you can also observe the remaining time of process throughthepushbuttons 6 3 6 Registers of minimum and maximum temperature 6 3 7 Steam Activation Iftheoperationmodeofthe2ndstageisconfi...

Страница 3: ...caltimer Timeforactivationof2ndstagecyclictimer OperationModeofaudiblealarm Activationpointofaudiblealarm lowerlimit Activationpointofaudiblealarm upperlimit Timeaudiblealarmisconnected Timeaudiblealarmisdisconnected Audiblealarmdeactivationtimewhenturningthecontrolleron Timetoreactivatetheaudiblealarmwhenmanuallydisabled Enablingandviewingmodeoftheprocesstimer Timebaseofthetimer Audiblealertatthe...

Страница 4: ...etoactivatethesteamoutput F28 11 IsthetimeforwhichOUT2willremainonduringthesteamactivationusingthekey F56 Timebetweenactivationsofthesteamoutput F28 11 Istheminimumtimebetweensteamactivationusingthekey Thisfunctioncanbedisabledbyadjustingittotheminimumvalue0 No F57 Pre processtime F49 0 Is the time that precedes the process time The normal process time is started after this time During the pre pro...

Страница 5: ... products are 100 recyclable Try to performdisposalthroughspecializedrecyclers Product The components used in Full Gauge controllers can be recycled and reused if disassembledbyspecializedcompanies Disposal Do not incinerate or dispose the controllers that have reached the end of their service as household garbage Observe the laws in your area regarding disposal of electronic waste Ifindoubt pleas...

Отзывы: