Full Gauge Controls MT-622E Скачать руководство пользователя страница 1

TWO STAGE DIGITAL CONTROLLER

WITH ALARM AND CYCLIC TIMER

AND PROCESS TIMER

4. INDICATIONS AND KEYS

5. INSTALLATION - ELECTRICAL CONNECTIONS AND PANEL

6. OPERATIONS

6.1 Facilitated menu map

By pressing 

;

 it is possible to navigate through the function menus. For more details, see chapter 6.3. 

See the functions map below:

6.2 Facilitated key map

When the controller is on display temperature, the following shortcut keys are used for the following 
functions:

/

Pressed 2 seconds: Adjusts the setpoint or change of recipe.
Short press: Inhibits alarm and buzzer (if activated).

Panel (Front View)

Panel

(Side View)

Dimension of the clipping

for setting of the

instrument in panel

71 

 mm

± 0,5

29 

 mm

± 0,5

 

1. DESCRIPTION

2. APPLICATIONS

3. TECHNICAL SPECIFICATIONS

The 

MT-622

e

 is a temperature controller that uses a thermocouple type J as sensor, has two 

outputs for temperature control and internal buzzer. It also has a timer that can operate in different 
modes, triggered by digital inputs, which indicates the end time of one or two processes.
The first stage can use a cyclic preheating mode, and the second stage can function as an alarm, a 
cyclic timer or end of process indication. It is also possible to use 5 configurable recipes, which allows to 
quickly change the values for the temperature setpoint and the hysteresis of the first stage and the 
processing time.
Product complies with UL Inc. (United States and Canada).

         

• Fryers
• Ovens

evolution

 

 

/

Control functions

shutdown

Functions

lockdown

Serial

programming

Protection

level

Buzzer

IP 65

FRONT

MT-622

e

 

Ver

.08

MT-622

  

MT-622

 

E251415

Control temperature

 

 0 to 600°C / 32 to 1112°F

Power supply

MT-622E: 

115/230 Vac ±10% (50/60 Hz)

MT-622EL: 

12/24 Vac/dc +10% (50/60 Hz)  

Operating temperature

 

0 to 50 ºC / 32 to 122ºF 

Operating humidity

10 to 90% UR (non-condensing)

Dimensions (mm)

76 x 34 x 77 mm (WxHxD)

Current output

 OUT 1:

 16(8)A / 250 Vac 1HP - 4000W

 

OUT 2:

 5(3)A / 250 Vac 1/8HP

Dimensions of the clipping for 

fixing of the instrument

71 ± 0,5 x 29 ± 0,5 mm (see item 5)

Resolution

1ºC / 1ºF

Sensor

J type Thermocouple 

(sold separately)

MT-622

e

 

Set key

Quick access 

menu (Flatec)

Increase key

Decrease key

Output OUT1 drive indicator LED

Output OUT2 drive indicator LED

Internal buzzer drive indicator LED

Pre-process/process timer indicator LED

Function locks indicator LED

Temperature unit indicator LED

WARNING

ACCESSORIES:

Only use original Full Gauge Controls accessories. 
If you have any questions, please contact technical support.

AUTHORIZED SERVICE:

The installation or maintenance of the product must be performed by qualified professionals only;

BEFORE  INSTALLING  THE  CONTROLLER,  WE  RECOMMEND  READING  THROUGH  THE 

ENTIRE  INSTRUCTION  MANUAL  IN  ORDER  TO  AVOID  POSSIBLE  DAMAGE  TO  THE 

PRODUCT.
PRECAUTIONS WHEN INSTALLING THE PRODUCT:

Before performing any procedure on this instrument, disconnect it from the mains;
Ensure  that  the  instrument  has  adequate  ventilation  and  avoid  installation  in  panels  containing 
devices that may cause it to operate outside the specified temperature limits;
Install  the  product  away  from  sources  that  may  generate  electromagnetic  disturbances  such  as: 
motors, contactors, relays, solenoid valves, etc; 

DUE TO YOUR CONSTANT EVOLUTION, THE FULL GAUGE CONTROLS RESERVES THE RIGHT TO 

CHANGE THE INFORMATION CONTAINED IN THIS MANUAL AT ANY TIME WITHOUT NOTICE.

FOR INSTALLATIONS WHERE A SEALING IS REQUIRED 
TO  AVOID  LIQUID  CONTACT,  THE  CUT  FOR  THE 
CONTROLLER MUST BE OF 70,5X29mm MAXIMUM. THE 
SIDE  LOCKS  MUST  BE  FIXED  SO  IT  PRESSES  THE 
RUBBER  SEALING  AVOIDING  INFILTRATION  BETWEEN 
THE CUT AND THE CONTROLLER.

ATTENTION

IMPORTANT

SCREWDRIVER SLOT 3/32''(2.4mm) FOR ADJUSTMENTS IN THE 
SIGNAL TERMINALS;
SCREWDRIVER PHILLIPS #1 FOR ADJUSTMENTS IN THE POWER 
TERMINALS;

THE  USE  OF  APPROPRIATE  TOOLS  IS  ESSENTIAL  TO  AVOID 
DAMAGE IN THE CONNECTION AT INSTRUMENT TERMINALS:

Connection

115 Vac

12 Vac/dc

1

5 6 7 8

2 3 4

9

POWER SUPPLY

10 11 12 13 14 15 16 17

5A

16A

OUT 2

+

-

RED

BLUE

DIG1

DIG2

DIG3

DIG4

Thermocouple

‘‘J’’ 

*

Type

OUT 1

C2

115 Vac

12 Vac/dc

COMMON

C1

1

5 6 7 8

2 3 4

9

POWER SUPPLY

10 11 12 13 14 15 16 17

5A

16A

OUT 2

+

-

RED

BLUE

DIG1

DIG2

DIG3

DIG4

OUT 1

230 Vac

24 Vac/dc

Connection

230 Vac

24 Vac/dc 

COMMON

C2

C1

Thermocouple

‘‘J’’ 

*

Type

*Sensor sold separately

C2

C1

and         loads

;

LOCK FUNCTION

;

CONTROL FUNCTIONS
SHUTDOWN

ADJUSTING THE DESIRED
TEMPERATURE (SETPOINT)

;

EXIT THE MENU

;

FUNCTION SELECTION

;

CLEAR VALUES MÍN. AND 
MÁX.

;

REGISTRATION OF 
TEMPERATURE 
MÍN. AND MÁX.

;

MT-622

e

 

MT-622

e

 

MT-622

e

 

MT-622

e

MT-622

e

 

MT-622

e

 

MT-622

e

 

<

<

Short press: Maximum and minimum temperatures display.

Enter the function selection.

<

Short press: With process timer driven -

                      Switches display between temperature and remaining time.

/

Short press: Starts process.
Short press: Ends process.*

>

<

POWER SUPPLY

Pins

12 and 13
12 and 14

MT-622E

115 Vac
230 Vac

MT622EV08-01T

-15736

MT-622EL

12 Vac/dc
24 Vac/dc

<

Pressed second

 1 

: Steam output activation.

*

 (F28=11), the time for pressing the key 

becomes 4 seconds to end the process. 

If the operation mode of the 2nd stage is configured as steam

Содержание MT-622E

Страница 1: ...ories If you have any questions please contact technical support AUTHORIZED SERVICE The installation or maintenance of the product must be performed by qualified professionals only BEFORE INSTALLING THE CONTROLLER WE RECOMMEND READING THROUGH THE ENTIRE INSTRUCTION MANUAL IN ORDER TO AVOID POSSIBLE DAMAGE TO THE PRODUCT PRECAUTIONS WHEN INSTALLING THE PRODUCT Before performing any procedure on thi...

Страница 2: ...mperatureandremainingtimeofeachprocess Temp Temperature Tmr1 Remainingtimeofprocess1 Tmr2 Remainingtimeofprocess2 Tmr3 Remainingtimeofprocess3 Tmr4 Remainingtimeofprocess4 Note In operating modes 1 and 4 of the F49 you can also observe the remaining time of process throughthepushbuttons 6 3 6 Registers of minimum and maximum temperature 6 3 7 Steam Activation Iftheoperationmodeofthe2ndstageisconfi...

Страница 3: ...caltimer Timeforactivationof2ndstagecyclictimer OperationModeofaudiblealarm Activationpointofaudiblealarm lowerlimit Activationpointofaudiblealarm upperlimit Timeaudiblealarmisconnected Timeaudiblealarmisdisconnected Audiblealarmdeactivationtimewhenturningthecontrolleron Timetoreactivatetheaudiblealarmwhenmanuallydisabled Enablingandviewingmodeoftheprocesstimer Timebaseofthetimer Audiblealertatthe...

Страница 4: ...etoactivatethesteamoutput F28 11 IsthetimeforwhichOUT2willremainonduringthesteamactivationusingthekey F56 Timebetweenactivationsofthesteamoutput F28 11 Istheminimumtimebetweensteamactivationusingthekey Thisfunctioncanbedisabledbyadjustingittotheminimumvalue0 No F57 Pre processtime F49 0 Is the time that precedes the process time The normal process time is started after this time During the pre pro...

Страница 5: ... products are 100 recyclable Try to performdisposalthroughspecializedrecyclers Product The components used in Full Gauge controllers can be recycled and reused if disassembledbyspecializedcompanies Disposal Do not incinerate or dispose the controllers that have reached the end of their service as household garbage Observe the laws in your area regarding disposal of electronic waste Ifindoubt pleas...

Отзывы: