Full Gauge Controls MT-514 E Faston Скачать руководство пользователя страница 5

 9. OPTIONAL ITEMS - Sold Separately

EASYPROG

 10. ANNEXES - Reference Images

Image V

Image X

Image VI

Image VII

Y

X

PANEL

PANEL

LATCHES

CONTROLLER

CONTROLLER

Image VII

CONTROLLER

VINYL

Image IX

Para uma instalação correta e 
segura, realize todas as conexões 
antes de fixar o controlador.

F41 - Display indication:

Defines wheter the display will show the sensor temperature in real time or a static message on the 
display.

[0]

- Displays the sensor temperature in real time

[1]

- Does not display the temperature, only the message 

[CooL]

 on the display

[2]

- Does not display the temperature, only the message

[,USE]

on the display

Note:

 If this function is configured as 

[CooL]

 or 

[,USE]

 it is possible to view the temperature 

measured by the sensor at any time with a short touch on the 

>

key, where, firstly the message of the 

process in progress will be displayed as well as the elapsed time of this process and then the message

 

[tEMP]

 followed by the display of the temperature measured by the sensor, for a few seconds on the 

display.

F42 - Functions lockdown:

This allows and configures the functions lockdown.

[,,,0]

- Do not allow the functions lockdown.

[,,,1]

- Allow a partial lockdown where the control functions will be locked but the adjustment of the 

setpoint, manual defrost, and maximum and minimum record are allowed.

[,,,2]

-  Allow  the  full  lockdown,  enabling  only  the  manual  defrost  and  maximum  and  minimum 

record.

F43 -Time for functions lockdown:

Allow lockdown of control functions (see item 7.3.3).

[,,15]

 - 

[,,60]

 Defines the time in seconds for the controller to activate.

F44 - Control functions shutdown:

Allow control functions shutdown (see item 7.3.4).

[no,,]

- Disables the control functions shutdown.

[,,,1]

- Enables activation/deactivation of the control functions only if the functions are unlocked.

[,,,2]

- Enables activation/deactivation of the control functions even if the functions are locked.

 8. SINALIZAÇÕES

[Err1] 

[Defr][On,,] 

[defr][Off,]

Sensor disconnected or damaged.

Manual activation of defrost process.

Manual activation of end of defrost process.

Control functions off.

Contact Full Gauge Controls.

Reconfigure the values of the functions.

[OFF,]

[eCAL]

[pppp]

Low temperature alarm.

[Atlo]

[inib] 

[LOC,][On,,]

[LOC,][OFF,]

[AVoL]

[AOPn]

[OpEn]

Power outage alarm indication.

Open door alarm indication.

Open door indication.

Functions lockdown.

Unlocking of functions.

Buzzer inhibited.

[Athi]

[ALrC]

High temperature alarm.

Compressor reached maximum time on limit without reaching SP.

 

 - version 2 or higher

EasyProg

It is an accessory that has as its main function to store the parameters of the controllers. At any time, you 
can load new parameters of a controller and unload them on a production line (of the same controller), 
for example. It has three types of connections to load or unload the parameters:

- Serial RS-485:

 It connects via RS-485 network to the controller (only 

for controllers that have RS-485). 

- USB:

 it can be connected to the computer via the USB port, using 

Sitrad's Recipe Editor.

-  Serial  TTL: 

The  controller  can  be  connected  directly  to 

EasyProg 

by the TTL Serial connection.

Ecase

It is recommended for the Evolution line, keeps water from entering the back part of the instrument. It 
also protects the product when the installation site is washed.

Extension Frame

The Full Gauge Controls extension frame allows the installation of Evolution / Ri line with measures 
76x34x77  mm  (dimensions  of  the  clipping  for  fixing  in  the  extension  frame  is  71x29mm)  in  varied 
situations, since it eliminates precision cut to embed the instrument. Allows customization via a sticker with 
the brand and the company contact, and accompany two 10A (250 Vac) switches that can trigger internal 
light, air curtain, on / off system or fan.

Note:

  Ecase  is  compatible  with  the  use  of 

small  type  Faston  terminals,  usually  with 
silicone protection.

Electrical noise suppressing filter

Contact suppressor connection 
diagram

A1

A2

A1 and A2 are the
contactor coils.

Diagram for suppressor installation 
for direct drive load inputs

Load

Suppressor

For  direct  activation  the 
maximum specified current 
should  be  taken  into 
consideration.

RC FILTER

Suppressor

IMPORTANT:

Faston connectors should be 
protected with covers, preferably 
silicone.

Отзывы: