4.3. Events schedule operating mode

In this option, you can choose how the events planner will operate.

- Weekly programming

 - In this mode, the instrument can configure up to 4 events for every day of 

the week.

- Programming for business days

 - In this mode, the instrument keeps the events the same for 

business days (Monday through Friday), and allows the programming of different events for Saturday 
and Sunday.

- Daily programming 

- In this mode, the instrument keeps the events the same for all of the days of 

the week.

F22 - Solar backing 2 activation hysteresis

Hysteresis setting for solar backing 2 activation temperature setpoint.

F23 - Minimum value for solar backing 2 temperature setpoint

Lower threshold aimed at preventing an exceedingly low temperature setpoint from being adjusted 
inadvertently for solar backing 2.

F24 - Maximum value for solar backing 2 temperature setpoint

Upper threshold aimed at preventing an exceedingly high temperature setpoint from being adjusted 
inadvertently for solar backing 2.

F25 - Solar backing 2 manual activation time

Time for which solar backing 2 stays on when activated manually. After this time solar backing 2 returns 
to automatic operation.

F26 - Cyclic timer on time

It allows adjusting the time for which the cyclic timer keeps its output on.

F27 - Cyclic timer off time

It allows adjusting the time for which the cyclic timer keeps its output off.

        

Cyclic timer with initial state "off" and linked to the event schedule

    

Cooling  thermostat  for  heat  dissipation  to  reduce  any  excess  temperature  in  the  water 

      tank.

F21 - Solar backing 2 temperature setpoint

Allows setting the activation temperature for solar backing 2.

5 -

6 -

F28 - Event schedule linking mode

It allows linking the solar backing outputs to one or more of the four daily events.  The possible modes 
are:
             

0  - 

 Aux 1 linked to events 1, 2, 3 and 4

      

2 -

 Aux 1 linked to events 1 and 2

   Aux 2 linked to events 1, 2, 3, and 4  

        Aux 2 linked to events 3 and 4

   

1  -

  Aux 1 linked to event 1 

           

3 - 

Aux 1 linked to events 1, 2, and 3  

   Aux 2 linked to events 2, 3, and 4

         Aux 2 linked to event 4         

 

F29 - Minimum S1 temperature alarm

Temperature for sensor 1 low temperature alarm indication

F30 - Maximum temperature alarm on S1

Indication temperature of high temperature on sensor 1

5. SIGNALING

Power LED blinking slowly - Controller configuration corrupted
Power LED blinking rapidly - Temperature sensor disconnected

F34 - RS-485 network address

®

Equipment's network address for communicating with SITRAD  software, Wall-Link and Wall-Fi.
Note: one network must not have different equipment with the same address.

To deactivate the temperature sensor of the backups (sensor 3) just set this function to its maximum 
value. 
If the activation of the water pump is linked to sensor 3 and this sensor is disabled, the controller will 
automatically unlink them.

F31 - S1 temperature indication offset

It allows setting sensor 1 (collectors) temperature indication offset.

F32 - S2 temperature indication offset

It allows setting sensor 2 (tanks/swimming pool) temperature indication offset.

F33 - S3 temperature indication offset

It allows setting sensor 3 (solar backing systems) temperature indication offset.

If you do not need to use the four events, you can configure it to be deactivated, and all you have to do 
isconfigure  the  off  time  (

Off1

  for  example)  with  the  maximum  value.  It  is  also  possible  to 

configure an event to overlap that it begins in one day and it finishes in the other, and for that you should 
adjust the off time with the option  

Cro

  and adjust an event for the next day to start at 00h and 00min. 

According to the operating mode configured, the following scheduling possibilities may be presented.

Sunday

Weekly schedule

Scheduling for business days

Daily schedule

Monday
Tuesday
Wednesday
Thursday
Friday
Saturday

Monday through Friday
Saturday

Sunday

Everyday

Events that are programmable

On4 -

 Start time for fourth event

Off4

 

-

 End time for fourth event

On1-

 Start time for first event

Off

 

1-

 End time for first event

F20 - Solar backing 2 operating mode

It allows setting up the operating mode of the solar backing 2 output. The modes are:

Cooling thermostat

Heating thermostat
Cooling thermostat linked to the event schedule
Heating thermostat linked to the event schedule
Cyclic timer with initial state "off”

0 - 

1 - 

2 - 

3 - 

4 - 

6. WIRING DIAGRAM

Se

ria

l c

om

m

un

ica

tio

n

RS

-4

85

Se

ns

or 1

 (c

ol

lec

to

rs

)

Se

ns

or 2

(re

se

rv

oi

r/p

oo

l)

Se

ns

or 3

(s

ol

ar b

ac

kin

gs

)

90 ~ 264 Vac*

(50/60Hz)

(12Vac/dc)

Load 2

suplly

suplly

Load 1

Pump

supply

LOAD 2

LOAD 1

PUMP

Above the current specified

 use contactor

Note: 

The sensor cable length can be increased by the user until 200 meters using

 PP 2 x 24 AWG cable.

MOD 64

A B

A

A

B

B

A B

A B

RS-485 Network

A

B

Instrument

RS-485 Network

®

7 INTEGRATING

INTERFACE 

AND COMPUTER

 

, SERIAL 

RS-485 

MICROSOL II POWER

A

A

B

B

A B

OUT

 

1

OUT 2

OUT 3

PCT-400R  

plus

OUT 4

ALMR

A

A

B

B

A B

A

A

B

B

A B

Serial interface 

 RS-485

Full Gauge

External

mesh

Distribution Box 

Used to connect more than one instrument to the Interface. The wire's connections must 
be made in agreement with the following rules: terminal 

A

 of the instrument connects to 

the terminal 

A

 of the distribution box, that must be connected with the terminal 

A

 of the 

Interface. Repeat the action for terminals 

B

 and 

     

, being      the cable shield.  

The terminal     of distribution box must be connected to the respective terminals       of 
each instrument.

RS-485 Serial Interface

®

Device  used  to  establish  the  connection 
Full Gauge Controls’ instruments with the 
Sitrad

.

terminal 

grounded

Microsol II power

4.4. Programming of the events schedule

In this option, you can enter the values for the time periods for each event. The entry of the data 
depends on the operating mode configured. You can configure up to four events for each day. For each 

event, the start and end time are configured through the options 

On1...Off1

 up to 

On4...Off4

,  

where:

On1- 

Start time for the first event

Off

 

1-

  End time for the first event

On4 -

 Start time for the 4º event

Off4

 

-

 End time for the 4º event

* Also available in 12Vac/dc

Capsule

Sensor

Metal

Plastic

 

Plastic

Function

Collectors

Reserv./Pool

Solar Backings

Maxinum temp.

operation 

200°C / 392°F

105°C / 

105°C / 

   

221°F

221°F

S1

S2

S3

Material

Silicone

PVC

PVC 

 Keep Sitrad updated in website: