![Full Boar FBCBA-2000 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/full-boar/fbcba-2000/fbcba-2000_instruction-manual_2345235012.webp)
22
23
Print test results
1.
Before selecting print data from the main menu, it is necessary to connect the
tool to the computer via the supplied Mini USB cable (10).
2.
Download the software from
www.fullboartools.com.au
and navigate to the
product page for this product.
3.
First open the "usb driver" folder (fig. 31) and install the USB Driver (fig. 32).
4.
Open "Print Software" folder and select
Printer (fig. 33).
5.
Check that the FBCBA-2000 is connected
to the correct "COM" connection and
OPEN PORT before printing the test
results (fig. 34).
Once port is opened, the text will change to
CLOSE PORT. To change "COM" connection,
select close port and change the connection
before selecting OPEN PORT again.
OPERATION (cont.)
Fig. 31
Fig. 33
Fig. 32
OPERATION (cont.)
Fig. 36
6.
From the Main Menu of the FBCBA-2000, use the up button (8) and down
button (6) to select Print option and press enter button (7).
7.
From the Print Data menu (fig. 35), use the
up button (8) and down button (6) to select
your print option and press enter button (7).
Note:
If no results appear on the program
after pressing enter button, check that OPEN
PORT has been selected or try selecting
different COM port.
8.
The selected test data will then
be shown on the print software
(fig. 36). Print the test results via
your PC printer.
Print Data
1. Print Battery
2. Print Cranking
3. Print Charging
4. Print All
Fig. 35